Owner's Manual

In very humid areas. Moisture or steam can cause nuisance
alarms.
In insect-infested areas.
Smoke alarms should not be installed within 3 ft (.9m) of the
following: the door to a kitchen, the door to a bathroom con-
taining a tub or shower, forced air supply ducts used for heating
or cooling, ceiling or whole house ventilating fans, or other high
air flow areas.
Kitchens. Normal cooking may cause nuisance alarms. If a
kitchen alarm is desired, it should have an alarm silence feature.
Near fluorescent lights. Electronic “noise” may cause nuisance
alarms.
• Smoke alarms are not to be used with detector guards unless
the combination (alarm and guard) has been evaluated and
found suitable for that purpose.
• Battery powered smoke alarms are not designed to be installed
over an electrical box or opening and must not be installed in
this manner.
3. INSTALLATION INSTRUCTIONS
CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOV-
ABLE!
NOTE: THE 29HIJ MOUNTING PLATE MOUNTS IN AN IDENTICAL
MANNER EVEN THOUGHT IT IS DIFFERENT IN APPEARANCE.
When mount-
ing in a hallway,
the “A” line
should be
parallel with
the hallway.
For wall mount-
ing the “A”
line should be
horizontal and
the arrow must
be pointing up.
Alignment Marks
FIGURE 5
FIGURE 4
FIGURE 6 FIGURE 7
Push Down
Alignment
Marks
Install
Remove