Owner's Manual
2. Firmly depress the test button for at least ten (10) seconds. The
smoke alarm will sound its alarm horn loudly. The alarm may
sound for up to 10 seconds after releasing the test button.
3. If smoke alarm does not sound, replace the smoke alarm
immediately. If the smoke alarm is under warranty, see warranty
information at the end of this manual for more information.
REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST
FUNCTION DOES NOT OPERATE PROPERLY AFTER FOLLOW-
ING THE PROCEDURES OUTLINED ABOVE (see REPAIR on
page 5).
LED Power/Alarm Indicator
The visual LED indicates the following:
Special Features of Model CCPB
Quick-Quiet™ Alarm Control
When activated, Quick-Quiet™ Alarm Control quiets unwanted
alarms for a maximum of 15 minutes. Always check that the smoke
alarm has activated in a false alarm situation. Be sure a real fire
emergency does not exist.
To use the Quick-Quiet™ Alarm Control feature:
Press and release the test button during an unwanted alarm. The
alarm should stop within ten seconds. The LED will flash about once
every 10 seconds. This means the smoke alarm is in Quick-Quiet™
Alarm Control mode.
If the smoke alarm does not go into Quick-Quiet™ Alarm Control and
continues to sound its loud alarm horn, or if it initially goes into
Quick-Quiet™ Alarm Control then resounds the alarm, the smoke is
very heavy. This is possibly a dangerous situation — take emergency
action immediately.
Chamber Test Feature
Once a minute the unit performs a chamber test. If at any time the
unit chirps and the LED does not flash – see Maintenance and
Cleaning section of this manual.
Battery Replacement
Replace battery at least once a year or immediately when the low
battery signal (a chirp) sounds once a minute. Use only the following
batteries as replacements in this smoke alarm: Duracell MN 1604
and long life lithium battery Ultralife U9VL-J.
DO NOT USE ANY OTHER TYPE OF BATTERY, EXCEPT AS SPECI-
FIED IN THIS MANUAL. DO NOT USE RECHARGEABLE BATTERIES.
1. Turn smoke alarm counter-clockwise to detach from mounting
plate.
2. Remove battery from pocket. Disconnect and discard drained
battery from battery connector.
3. Connect a fresh 9-volt or 9-volt lithium battery to connector. The
battery will fit only one way. Be sure battery connector is securely
attached to battery terminals.
4. Push test button for at least ten (10) seconds. The alarm horn
should sound. This means the battery is connected properly.
5. Place battery into battery pocket. Close battery pocket door.
Push down until it snaps into place.
6. Reattach smoke alarm to mounting plate. To do so, turn smoke
alarm clockwise until it snaps into mounting plate.
7. Test smoke alarm using test button as described in the
TESTING YOUR SMOKE ALARM section of this manual.
Maintenance and Cleaning
In addition to weekly testing, this smoke alarm requires yearly battery
replacement and periodic cleaning to remove dust, dirt, and debris.
A long life lithium battery can be expected to last as long as five (5)
years, but is warrantied for one (1). The National Fire Protection
Association (NFPA) recommends replacing your smoke alarms every
ten (10) years.
Cleaning
Clean the smoke alarm at least once a month to remove dust, dirt, or
debris as follows:
• Using the wand attachment of a vacuum cleaner, vacuum all sides
and cover of smoke alarm. Be sure all the vents are free of debris.
• If necessary, remove battery and use a damp cloth to clean smoke
alarm cover.
IMPORTANT: Do not attempt to remove the cover or clean inside the
smoke alarm. THIS WILL VOID YOUR WARRANTY.
5
Blinks once a minute
Normal operation–smoke alarm is receiving battery power
Blinks once a second
Smoke is detected; audible alarm will simultaneously sound
Blinks once every 10 seconds
Quick-Quiet
™
Alarm Control is actively quieting an
unwanted alarm
WARNING
!