Owner's Manual

2. To open battery door, insert screwdriver into slot and depress
while sliding door open.
3. Remove drained battery from compartment and discard.
4. Insert a fresh 9-volt battery.
5. Slide battery door closed.
6. Turn on power and test smoke alarm using FALSE
ALARM/TEST button.
7. For item 755 only, confirm that red LED is not flashing. If not,
repeat testing procedure until it does.
Use only the following batteries as replacements: Model 755
Eveready 522, 216, 1222 or Duracell MN 1604.
WARNING: Using inferior batteries or the incorrect type may
cause the alarm to malfunction.
NOTE: The 755RL rechargeable lithium batteries are permanent-
ly mounted and sealed in the tamper-proof housing. These cells
are designed to last the useful life of the Smoke Alarm of 10
years. The 755 has a front access battery door which allows a
home owner to safely change the battery.
OPERATION AND TESTING
The Clipsal Lifesaver
®
755 Series Smoke Alarms are opera-
tional once all of the connections are correctly made, the 9V
battery installed (model 755) and mains power restored.
Test the alarm by pushing the FALSE ALARM/TEST button
for 5 seconds. The alarm should sound simultaneously.
This test should be done at least once a week to ensure that
the alarm is operating correctly.
The 755 has a ramp-up test feature that emits two reduced-
volume beeps before reaching the full 85dB level during
testing.
If interconnected alarms are installed, pushing the FALSE
ALARM/TEST button on one unit should cause all
interconnected units to sound.
If the alarm does not sound, check the wiring, 9V battery,
fuses or circuit breaker and make sure that the alarm is con-
nected to a 240V a.c. supply which cannot be inadvertently
turned off.
9