Owner's Manual
2. To open battery door, insert screwdriver into slot and depress
while sliding door open.
3. Remove drained battery from compartment and discard.
4. Insert a fresh 9-volt battery.
5. Slide battery door closed.
6. Turn on power and test smoke alarm using FALSE
ALARM/TEST button.
7. For item 755 only, confirm that red LED is not flashing. If not,
repeat testing procedure until it does.
Use only the following batteries as replacements: Model 755
Eveready 522, 216, 1222 or Duracell MN 1604.
WARNING: Using inferior batteries or the incorrect type may
cause the alarm to malfunction.
NOTE: The 755RL rechargeable lithium batteries are permanent-
ly mounted and sealed in the tamper-proof housing. These cells
are designed to last the useful life of the Smoke Alarm of 10
years. The 755 has a front access battery door which allows a
home owner to safely change the battery.
OPERATION AND TESTING
• The Clipsal Lifesaver
®
755 Series Smoke Alarms are opera-
tional once all of the connections are correctly made, the 9V
battery installed (model 755) and mains power restored.
• Test the alarm by pushing the FALSE ALARM/TEST button
for 5 seconds. The alarm should sound simultaneously.
• This test should be done at least once a week to ensure that
the alarm is operating correctly.
• The 755 has a ramp-up test feature that emits two reduced-
volume beeps before reaching the full 85dB level during
testing.
• If interconnected alarms are installed, pushing the FALSE
ALARM/TEST button on one unit should cause all
interconnected units to sound.
• If the alarm does not sound, check the wiring, 9V battery,
fuses or circuit breaker and make sure that the alarm is con-
nected to a 240V a.c. supply which cannot be inadvertently
turned off.
9
Insert
Screwdriver here