Installation Guide
7
4. Troubleshooting Guide
3. Other Alarm Visual And Audible Indicators
If you require further information please contact Product Support at 1-800-880-6788 or write us at:
Kidde, 1016 Corporate Park Drive, Mebane, NC 27302. Our internet address is www.kidde.com.
Operational Mode Visual Indications Audible Indications Action/Note
Initiating Alarm
(multiple alarms in an
interconnected system)
Red LED blinks in time with
alarm pattern indicating that
this is the unit initiating the
alarm in an interconnected,
multiple alarm, system.
NOTE: It is possible for more
than one unit to detect a haz-
ard and become an initiating
alarm unit (Red LED blinking).
Unit in either Smoke or CO alarm
mode.
Trouble Condition
Visual Indications Audible Indications Action
False Low Battery
(AC power
connected before
backup batteries
activated)
None. Chirp and voice “Activate Battery”
every 60 sec. After 1 hour, voice
occurs only once every 15 mins.
* Pull the battery pull tab to activate the
backup batteries.
Low Battery Amber LED blinks every
60 sec.
Chirp and voice “Low Battery”
every 60 sec. After 1 hour, voice
occurs only once every 15 mins.
After button push, voice “Hush
Mode Activated.”
* Push button once to silence for 24 hrs.
(Push button again to clear Hush
TM
and
perform a test.) Note: 7 days after Low
Battery begins, the notifications cannot
be silenced.
* Replace batteries as soon as possible.
Smoke Sensor Fault Amber LED blinks every
60 sec.
3 chirps every 60 sec and voice
“Smoke Sensor Error.” After 1 hour,
voice occurs only once every
15 mins..
* See Cleaning Your Alarm section.
* Push button once to attempt to reset the unit.
* If error continues, remove alarm, dispose
unit, and replace as soon as possible.
CO Fault Amber LED blinks 2
times every 60 sec.
3 chirps every 60 sec and voice
“Replace Alarm.” After 1 hour, voice
occurs only once every 15 mins.
* Push button once to attempt to reset the
unit.
* If error continues, remove alarm, dispose
unit, and replace as soon as possible.
Fatal Fault Amber LED blinks 3
times every 60 sec.
3 chirps every 60 sec and voice
“Replace Alarm.” After 1 hour, voice
occurs only once every 15 mins.
* Push button once to attempt to reset the
unit.
* If error continues, remove alarm, dispose
unit, and replace as soon as possible.