Specification

Worry-Free Bedroom Smoke Alarm*
Sealed Lithium Battery Power with Voice Alarm
Model P3010B
Architectural and Engineering
Specifications
The smoke alarm shall be Kidde unit P3010B or approved equal. It
shall be powered by a non-replaceable lithium battery with 10-year
life. The lithium battery shall be sealed in the unit to prevent removal
and/or tampering. The unit shall incorporate a photoelectric sensor.
The temperature operating range shall be between 40ºF and 100ºF
(4ºC and 38ºC) and the humidity operating range shall be 10-95%
non-condensing relative humidity.
The smoke alarm can be installed on the surface of any wall or ceiling
following the UL/Manufacturer’s approved placement guidelines.
The alarm shall incorporate an automatic activation feature that will
activate the unit as soon as it is attached to the mounting bracket, no
other steps are involved.
The alarm shall include a test button that will simulate a fire
condition and cause the unit to go into alarm. This sequence tests
the unit’s electronics to ensure proper operation.
The unit shall have two audible methods for warning of smoke or
fire danger: a piezoelectric horn that is rated at 85 decibels at 10 feet
and a voice warning. In alarm, the horn will sound in the repetitive
manner – three (3) beeps, a pause, three (3) beeps, a pause. In
between, the unit will announce “Fire! Fire!.” A red LED will flash in
conjunction with the alarm sound.
The unit shall also indicate a low battery warning utilizing each of the
following methods: a brief alarm chirp every 60 seconds, the voice
announcement of “Low Battery!” and the red LED will flash once
every 30 seconds. The red LED will flash every 60 seconds for the first
10 minutes following power on or test, and once every 10 minutes
thereafter. It will also flash every 10 seconds while in Hush mode.
The smoke alarm shall include an End of Life Alert, where ten years
after initial power-up the unit shall chirp two times every 30 seconds
to indicate the alarm needs to be replaced. The End of Life indication
can be silenced three days at a time for a maximum of 30 days. The
unit shall have a deactivation switch to disable it and make it safe for
disposal.
The unit shall at a minimum meet the requirements of UL217,
NFPA 72, The State of California Fire Marshall, NFPA101 (One and
two family dwellings), Federal Housing Authority (FHA), Housing
and Urban Development (HUD). It shall also include a 10-year
manufacturer’s limited warranty.
Ordering Information
Technical
Specifications
Model: P3010B
Power Source: Sealed Lithium Battery
Sensor: Photoelectric
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range: 10-95% non-condensing
relative humidity (RH)
Size: 5.22” in diameter x 1.6” depth
Weight: 1 lb.
Interconnects: No
Warranty: 10 year limited
5.22" 1.6"
1016 Corporate Park Drive
Mebane, NC 27302
1-800-880-6788
www.Kidde.com
Distributed by:
P/N: PDS_KL_P3010B_0523.pdf rev. 05-2023
Ordering No: UPC I 2 of 5
Pack
Config.
Pack
Qty
Dimensions
(w” x d” x h”) Weight
Cartons/
Pallet
21032754 0-47871-30954-2 100-47871-30954-9 Clam 6 8.0 x 9.5 x 11.5 1.35 75