3. Other Alarm Visual And Audible Indicators
Operational Mode Visual Indications Audible Indications Action/Note
Normal (standby) AC power: Green LED on
continuously.
DC power: Green LED blinks
approx every 60 sec.
Test (button press when
no alarm condition is
present)
(Note: Test is very loud,
stand a few feet away.)
Red LED blinks in time with
alarm pattern.
Single beep.
3 long beeps, pause, 3 long beeps,
4 quick beeps, pause, 4 quick beeps.
Perform button press once a week to
verify proper alarm operation.
Smoke or CO Alarm
Memory (unit has
experienced a smoke or
CO alarm event, or has
detected 100ppm CO or
greater.)
Smoke: Red LED blinks
every 15 sec.
CO: 2 red LED blinks
every 15 sec.
NOTE: Alarm memory is only retained
for 24 hrs.
Push button to clear Alarm Memory.
Smoke Alarm Hush
TM
Mode
Red LED blinks every 2 sec. After button push, smoke alarm
pattern stops. (If there is too much
smoke to allow Hush
TM
, smoke alarm
pattern continues.)
This feature is to be used only when
a known alarm condition, such as
smoke from cooking, activates the
alarm.
Push button during Hush
TM
to clear
Hush
TM
and perform a test.
CO Alarm Reset None After button push: CO alarm pattern
stops.
Unit is conrming if CO is present or
if it experienced a nuisance situation.
Re-alarm means danger. Move to fresh
air and call 911.
Initiating Alarm
(multiple alarms in an
interconnected system)
Red LED blinks in time with
alarm pattern indicating that this
is the unit initiating the alarm
in an interconnected, multiple
alarm, system.
NOTE: It is possible for more than
one unit to detect a hazard and
become an initiating alarm unit
(Red LED blinking).
Unit in either Smoke or CO alarm
mode.