Installation Guide

15
NOTE: A dust cover has been installed on
the alarm. Keep the dust cover on until all
construction has been completed for at
least 24 hours (drywall, painting, varnishing,
mounting plate install, etc). Construction dust
and chemicals can cause contamination and
false alarms.
WARNING: DUST COVER MUST BE REMOVED FOR ALARM TO OPERATE.
Kidde alarms are not designed, agency tested or certified for recessed mounting
and should not be installed in this manner. Recessed mounting impedes smoke
entry into the smoke chamber, which may prevent the alarm from sounding in a
timely manner. This could endanger the lives of occupants in the residence. Kidde
alarms are designed, tested and certified for wall (if applicable) and ceiling surface
mount only.

This model meets the latest residential smoke alarm standards, which includes
enhanced resistance to nuisance alarms from cooking.
Operation
The alarm is operating once it is activated and testing is complete (see “Testing”
below). When products of combustion (smoke) are sensed, the unit sounds a loud
alarm. See Section 1 for alarm signal descriptions.
Testing
IMPORTANT: Retail canned smoke products vary by manufacturer and produce in-
consistent results. If the unit does not alarm when canned smoke is applied conduct
a push-to-test to verify proper operation. Over-application of canned smoke can
permanently damage the alarm.
Figure 8-E
Pull tab to
remove
dust cover.