Use and Care Manual
 CONTENTS OF THIS USER GUIDE
  1 —  LIMITATIONS OF SMOKE AND CARBON MONOXIDE ALARMS
  2 —  RECOMMENDED LOCATIONS FOR ALARMS
  3 —  LOCATIONS TO AVOID
  4 —  INSTALLATION / MOUNTING INSTRUCTIONS
  5 —  OPERATION AND TESTING
  6 — VISUAL AND AUDIBLE INDICATIONS
  7 —  NUISANCE AND HUSH
  8 —  BATTERY
  9 —  DEACTIVATION OF ALARM
  10 —  GENERAL CARBON MONOXIDE (CO) INFORMATION
  11 —  CLEANING YOUR ALARM
  12 —  GOOD SAFETY HABITS
  13 —  SERVICE AND WARRANTY
This alarm detects products of combustion using photoelectric technology 
and carbon monoxide using an electrochemical cell. Many times throughout 
this User Guide, we will refer to Carbon Monoxide as “CO.” 
After ten (10) years of cumulative power up, this unit will “chirp” two times 
every 30 seconds. This is an "operational end of life" feature which will indi-
cate that it is time to replace the alarm.
To help identify the date to replace the unit, a label has been affixed to the 
side of the alarm. Write the “Replace by” date (10 years from initial power 
up) in permanent marker on the label prior to installing the unit.
Product Features and Specifications:
• Temperature: Operating Range: 40°F (4.4°C) to 100°F (37.8°C) 
• Humidity: Operating range: 10-95% non-condensing 
• Audible Alarm: 85+ dB at 10’ @ 3.2±0.5 KHz pulsing alarm 
• Smoke Sensor: Photoelectric 
• CO Sensor: Electrochemical
Two labels have been provided that have important information on what 
to do in case of a CO alarm. Place one label next to the alarm after it is 
mounted, and one near a fresh air source such as a door or window.