Installation Guide
26
Industry Safety Standards
NFPA (National Fire Protection Association) 
For  your  information,  the National  Fire  Protection Association’s
Standard 72, reads as follows:
Smoke Detection. Where required by applicable laws, codes, or
standards for  the  specified  occupancy,  approved  single-  and
multiple-station smoke alarms shall be installed as follows: (1) In
all sleeping rooms. (2) Outside of each separate sleeping area, in
immediate vicinity of the sleeping rooms. (3) On each level of the
dwelling  unit,  including  basements  Exception:  In  existing  one-
and two-family dwelling units, approved smoke alarms powered
by batteries are permitted.
Smoke Detection - Are More Smoke Alarms Desirable? The
required number of smoke alarms might not provide reliable early
warning protection for those areas separated by a door from the
areas protected by the required smoke alarms. For this reason, it
is  recommended  that  the  householder  consider  the  use  of
additional smoke alarms for those areas for increased protection.
The additional areas include the basement,  bedrooms, dining
room, furnace room, utility room, and hallways not protected by
the  required  smoke alarms.  The  installation  of  smoke  alarms in
kitchens, attics (finished or unfinished), or garages is not normally
recommended,  as  these  locations  occasionally  experience
conditions that can result in improper operation.
California State Fire Marshall
Early warning fire detection is best achieved by the installation of
fire detection equipment in all rooms and areas of the household
as  follows:  A  smoke  alarm  installed  in  each  separate  sleeping
area (in  the vicinity,  but outside the  bedrooms), heat or  smoke
detectors in the living rooms, dining rooms, bedrooms, kitchens,
hallways, attics, furnace rooms, closets, utility and storage rooms,
basements and attached garages.
Consumer Product Safety Commission
The Consumer Product Safety Commission (CPSC) recommends
the use of at least one CO Alarm per household, located near the
sleeping area.