Installation Guide

18
To activate the battery carrier tamper resist feature, remove the unit from the mounting bracket, disconnect the
AC quick connector and locate the small cut-out in the middle of the label on the back of the unit. With a small
screwdriver, or similar tool, slide the switch towards the “LOCK” position as
shown on the label(see Figure 9-F). The tamper resist feature is now active
and the battery carrier can not be opened until the tamper resist feature is
deactivated.
NOTE: Before activating the battery carrier tamper resist feature, make sure
a fresh battery is installed in the unit and that the battery carrier is properly
closed. If the battery carrier tamper resist feature is activated while the
battery carrier is open, the battery carrier will not close and the unit will be
inoperable during the loss of AC power.
To deactivate the battery carrier tamper resist, in order to change the smoke alarm battery, remove the unit
from the mounting bracket (see Smoke Alarm Tamper Resist Feature if activated), disconnect the AC quick
connector and locate the small cut-out in the middle of the back label. Using a screwdriver, or similar tool, slide
the switch in the opposite direction of the “LOCK” arrow as shown on the label. The battery carrier can now be
opened and the battery changed.
AC Wired Interconnect Model Capability
This model has AC hardwire interconnect capability. When one hardwired interconnect unit sounds an alarm, all
other compatible hardwire or interconnected units will also alarm.
The following models can be interconnected using the standard AC wiring interconnect: 1235, 1275,
1276, 1285, i12020, i12020A, i12040, i12040A, i12060, i12060A, i12080, i12080A, i4618, i4618A,
i4618AC, KN-SMFM-I, RF-SM-ACDC, PE120, P12040, Pi2000, Pi2010, KN-COSM-I, KN-COSM-IB,
KN-COSM-IBA, KN-COPE-I, KN-COPE-IC, KN-COB-IC, KN-COP-IC, SL177i, SLED177i, HD135F, SM120X,
CO120X, i12010S, i12010SCO, P4010ACSCO, P4010ACSCO-W, P4010LACS-W, P4010ACS, P4010ACS-W,
2070-VASCR, 2070-VASR, P4010ACLEDS-2, P4010ACLEDSCO-2.
The alarm is now activated! After installation / activation, test your alarm as described in Operation and
Testing section.
WARNING: FAILURE TO PROPERLY INSTALL AND ACTIVATE THIS ALARM WILL PREVENT
PROPER OPERATION OF THIS ALARM AND WILL PREVENT ITS RESPONSE TO FIRE HAZARDS.
Figure 9- F