Use and Care Manual

7
3. Troubleshooting Guide 4. Introduction, Product Features And Specifications
Introduction
This alarm detects products of combustion using a multi-criteria optical sensor.
Ten (10) years after the unit was installed, this unit will automatically alert you that it is time to replace the unit.
This is called “End of Unit Life” mode. See Troubleshooting Guide. To help identify the date to replace the unit,
a label has been affixed to the side of the alarm. Write the “Install date” in the space provided, and then write
in the “Replace by” date (10 years from initial power up) in permanent marker on the label prior to installing the
unit.
Product Features and Specifications:
Temperature Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
Humidity Operating range: up to 95% RH non-condensing
Audible Alarm: 85+ dB at 10, 3.0 to 3.5 KHz pulsing alarm, with voice message “Fire!
Smoke Sensor: Multi-Criteria Optical
Voice message system
Smoke Alarm SMART Hush® Control
Powered by a front load 9V battery.
One large, user- friendly button.