User Guide
21
13. Permanently Disable Alarm / Discharge Battery
 WARNING: FAILURE TO DISCHARGE ALARM BATTERY AS INSTRUCTED PRIOR TO
DISPOSAL MAY CREATE POTENTIAL FOR LITHIUM BATTERY RELATED FIRE OR HAZARD.
 WARNING: DISCHARGING THE ALARM BATTERY IS PERMANENT
 • Once the alarm battery has been discharged, it cannot be reactivated!
 • Once discharged, the alarm will NO LONGER DETECT SMOKE OR CO.
 • Once the alarm battery is discharged, the battery is depleted and the alarm will no longer function.
 • Once the alarm battery has been discharged, the alarm cannot be mounted onto the mounting plate or reactivated.
To Permanently Disable Alarm / Discharge Battery:
 • Rotate the alarm counterclockwise to remove it from the mounting 
plate. 
 • Disconnect AC wiring harness.
 • Push in the dashed area with a screwdriver to break tab (Figure 13-A).
 • After the tab is broken, use the screwdriver to turn the red slotted 
arrow to the "Permanently Disable Alarm / Discharge Battery" loca-
tion. This will disable the alarm, stop the low battery or end of unit 
life “chirps” and render the alarm safe for disposal by draining the 
battery (Figure 13-B).
Figures 13-A (top) and 13-B (bottom)