Installation Guide
16
NOTE: AC power should be turned off at this stage.
 • After selecting the proper location for your alarm, and wiring the AC QUICK CONNECT harness as described in the 
WIRING INSTRUCTIONS, attach the mounting bracket to the electrical box. To ensure aesthetic alignment of the 
alarm with the hallway, or wall, the “A” line on the mounting bracket must be parallel with the hallway when ceiling 
mounted, or horizontal when wall mounted.
 • Pull the AC QUICK CONNECTOR through the center hole in the 
mounting bracket and secure the bracket, making sure that the 
mounting screws are positioned in the small ends of the keyholes 
before tightening the screws. 
 • Plug the AC QUICK CONNECTOR into the wiring harness attached 
to the unit, making sure that the locks on the connector snap into 
place. Then push the excess wire back into the electrical box through 
the hole in the center of the mounting bracket.
 • Install the alarm fully on the mounting bracket by rotating the alarm 
in a clockwise direction. NOTE: The alarm will mount to the bracket 
in 4 positions (every 90 degrees). NOTE: Installing the alarm on the 
mounting bracket will automatically activate the battery backup.
 • Turn on the AC power. The green AC Power On Indicator should be lit when the alarm is operating from AC power.
NOTE: Attaching AC power first, without rotating the alarm onto the mounting bracket, will result in a low battery 
trouble condition chirp (see Troubleshooting Guide). You need to activate the battery to eliminate the low battery 
trouble condition chirps. Attach unit to mounting bracket very soon after applying AC power to avoid false low 
battery notification.
Existing Kidde 
AC Connector 
(either connector 
can be used for 
this model)
AC connector
shipped with 
product
AC connector
Figure 9-B