Use and Care Manual

Step 4: Hush
®
Control Feature
The Hush
®
featurehasthecapabilityoftemporarilydesensitizing
the smoke alarm circuit for approximately 10 minutes. This
feature is to be used only when a known alarm condition,
such as smoke from cooking, activates the alarm. You can put
your Smoke/CO Alarm in Hush
®
mode by pushing the test/
reset button. The unit will give a voice message “Hush mode
activated.” If the smoke is not too dense, the alarm will silence
immediately and the green LED light will flash every 2 seconds
for approximately 10 minutes. This indicates that the smoke
alarmisinatemporarilydesensitizedcondition.YourSmoke/CO
Alarm will automatically reset after approximately 10 minutes.
When the unit returns to normal operation after being in Hush
®
mode the alarm will sound if smoke is still present. The Hush
®
feature can be used repeatedly until the air has been cleared
of the condition causing the alarm. While the unit is in Hush
®
mode, pushing the test/reset button on the alarm will also end
the Hush
®
period. The unit will give a voice message “Hush
mode cancelled.”
NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH
®
CONTROL FEATURE AND SOUND A CONTINUOUS ALARM.
CAUTION: BEFORE USING THE ALARM HUSH
®
FEATURE,
IDENTIFY THE SOURCE OF THE SMOKE AND BE CERTAIN
A SAFE CONDITION EXISTS.
Step 5: Peak Level Memory
If the green LED is blinking once every 16 seconds, the unit has
detectedahazardouscondition.IftheCOsensorhasdetecteda
CO level of 100 PPM or higher since last reset, it will be recorded
by the Peak Level Memory function. To access the Peak Level
Memory press the test/reset button. If a reading of 100 PPM
or higher has been recorded the unit will give a voice message
“Caution, Carbon Monoxide previously detected.” If you’ve
been away from home this feature allows you to check if there
was a CO reading of 100 PPM, or higher, during your absence.
Pushing the test/reset button resets the memory. It’s also reset
when the batteries are removed. There is no voice message
associated with peak level due to smoke. When the test/reset
button is pushed, the unit exhibits a normal PTT if the peak level
is due to smoke.