Install at least one (1) foot away from fluorescent lights,
electronic noise may cause nuisance alarms. Do not place
in direct sunlight and keep out of insect infested areas.
Extreme temperatures will effect the sensitivity of the Smoke/
CO Alarm. Do not install in areas where the temperature
is colder than 40 degrees Fahrenheit (4.4 Celsius) or hotter
than 100 degrees Fahrenheit (37.8 Celsius), such as garages
and unfinished attics. Do not install in areas where the
relative humidity (RH) is above 85%. Place away from doors
and windows that open to the outside.
Smoke alarms are not to be used with detector guards unless
the combination (alarm and guard) has been evaluated and
found suitable for that purpose.
C. How to Install:
To help identify the date to replace the unit, a label has been
affixed to the side of the alarm. Write the “Replace by”
date (7 years from initial power up) in permanent marker
on the label. See Alarm Replacement section for additional
information.
Remove mounting plate from the back of the unit by holding
the rim of the mounting plate and twisting counterclockwise
(left). See Diagram C. Hold the mounting plate against the
selected installation location (wall or ceiling) and mark the
center of the holes with a pencil.