Installation Guide
This unit is equipped with a thermally protected class “P” ballast.
1) Turn off power supply at fuse box before installing xture
2) Remove ballast cover.
3) Remove 7/8” diameter wireway knockout at center of xture.
4) Position housing on ceiling and mark ceiling at mounting holes.
5) Be certain there are no obstructions above ceiling at mounting hole
location.
6) Drill holes at locations marked for desired mounting hardware.
2x2 HOUSING ONLY:
7) Pass wires from outlet box through bushed center hole in housing.
8) Attach housing to ceiling using screws provided or other mounting
hardware.
9) Grounding instructions: (See Illus. A or B).
A) On xtures where mounting strap is provided with a hole and two
raised dimples. Wrap ground wire from outlet box around green
ground screw, and thread into hole.
B) On xtures where a cupped washer is provided. Attach ground wire
from outlet box under cupped washer and green ground screw, and
thread into mounting strap.
If xture is provided with ground wire. Connect xture ground wire to
outlet box ground wire with wire connector (not provided.) After following
the above steps. Never connect ground wire to black or white power
supply wires.
10) Make wire connections (connectors not provided). Reference chart
below for correct connections and wire accordingly.
11) Re-attach ballast cover.
DECORATIVE FRAME INSTALLATION:
After the xture housing has been installed to your ceiling, attach the deco-
rative frame as follows:
1) Hook one side of decorative frame onto housing edge.
2) Push opposite side of decorative frame upward past housing
edge.
3) Shift decorative frame in direction of hooked side.
4) Drop decorative frame into place.
Squeeze to release from beneath metal clip.
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 3/02/07 IS-10304-US
HOUSING
DECORATIVE FRAME