Use and Care Manual
INSTALLATION INSTRUCTIONS
Your air conditioner is designed to install in standard double hung windows with opening widths of
23 to 36 inches(584mm to 914mm) (See Fig.1).
Lower sash must open sufficiently to allow a clear vertical
opening of 15-1/2 inches (394mm). Side louvers and the rear
of the AC must have clear air space to allow enough airflow
through the condenser, for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
NOTE: Carton Installation InstructionsSave and these
for future reference. The carton is the best way to store unit
during winter, or when not in use.
3 4 Screws
(7)
Lock Frame
(2)
Sash Lock
(1)
Mounting Hardware
TOOLS NEEDED:
CAUTION:
Phillips Screw Driver
Drill(If pilot holes are needed)
When handling unit, be careful to avoid cuts from
sharp metal edges and aluminum fins on front and rear coils.
Top Rail Hardware
3 8 Screws
(4)
Top Rail
(1)
Before installing unit, the top rail must be assembled
on the unit (For <10000Btu/h models only).
Tool Needed: Phillips Screwdriver
A: Remove the air conditioner from the carton and place
on a flat surface.
B: Remove top rail from the bottom of the packaging
material as shown in Fig.A
10
Fig.1
OFFSET
EX ERIOR
WALL
T
STOOL
SILL
INTERIOR
WALL
23 to 36
584mm to 914mm
15 1 2 min.
/
(394 mm)
NOTE:
more
than 10000Btu/h.
The top rail hardware and the following Fig.A,
Fig.B and Fig.C are not applicable to the units
Air Directional Louvers
The louvers will allow you to direct the air flow Up
or Down and Left or Right throughout the room as
needed. Pivot horizontal louvers until the desired
Up/Down direction is obtained.
Move the Levers from side to side until the desired
Left/Right direction is obtained.
Levers
Air Direction
Table 1
Size
Model
10000-12000Btu/h
8000Btu/h
14
(356mm)
15-1/2
(394mm)