Portable Air Conditioner Instruction Manual Thank you for purchasing our Portable Air Conditioner. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference.
Contents Preparation ---------------------- 2 Safety Precautions ---------------- 4 Cautions ------------------------ 5 Installation ---------------------- 6 O p e r a t i o n- - - - - - - - - - - - - - - - - - - - - - - - 1 0 Maintenance --------------------- 13 Faults Diagnosis ------------------ 14 Design and Compliance Notes ------- 15 Sociable Remark ------------------ 16 1
Preparation control panel horizontal louver blade upper air filter (behind the grille) handle (both sides) upper air intake Panel drain outlet air outlet lower air filter lower air intake Caster power plug socket power cord buckle power cord outlet bottom tray drain outlet front rear 2
Preparation NOTE: The unit you purchased may be look like one of the following(s): 3
Safety Precautions -DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit. -DO NOT install the unit in a location that may be exposed to combustible gas, as this could cause fire. -The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects, as these could cause tipping. -DO NOT operate a unit that has been dropped or damaged.
Cautions -This appliance can be used by children aged from 8 years and above and person with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Installation Note About Fluorinated Gasses Choosing The Right Location -This air-conditioning unit is a hermetically sealed unit that contains fluorinated gasses. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. -Installation, service, maintenance and repair of this unit must be performed by a certified technician. -Product uninstallation and recycling must be performed by a certified technician.
Installation Tools Needed Window Installation Kit Step One: Preparing the Exhaust Hose assembly -Medium Philips screwdriver; -Tape measure or ruler; -Knife or scissors; -Saw (optional, to shorten window adaptor for narrow windows) Accessories Press the exhaust hose into the window slider adaptor and unit adaptor, clamp automatically by elastic buckles of the adaptors. Your Window Installation Kit fits windows 67.5-123cm(26.5-48”) and can be shortened for smaller windows.
Installation Note: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods. Type 1: Hung Window Installation Foam seal B (Adhesive type-shorter) Window slider A Insert the window slider adaptor into the hole of the window slider. Window slider B (if required) Foam seal A (Adhesive type) Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown.
Installation Foam seal C (Non-adhesive type) Security Bracket 2 Screws Cut the non-adhesive foam seal C strip to match the window height. Insert the foam seal between the glass and the window frame to prevent air and insects from getting into the room. If desired, install the security bracket with 2 screws as shown. Insert the window slider adaptor into the hole of the window slider. Note: To ensure proper function, DO NOT overextend or bend the hose.
Operation Swing button Used to initiate the Auto swing feature. When the operationis ON, press the SWING button can stop the louver at the desired angle. Fan/Ion button(Ion is optional) Control the fan speed. Press to select the fan speed in four steps-LOW, MED(optional), HIGH and AUTO. The fan speed indicator light illuminates under different fan settings except AUTO speed. When select AUTO fan speed, all the fan indicator lights turn dark. NOTE: Press this button for 3 seconds to initiate ION feature.
Operation LED display Shows the set temperature in °C or °F and the Auto-timer settings and the humidity settings(only for modles with humidity sensor). While on DRY and FAN modes, it shows the room temperature. Shows Error codes and protection code: E1-Room temperature sensor error. E2-Evaporator temperature sensor error. E3-Condenser temperature sensor error (on some models). E4-Display panel communication error. E7-Zero-crossing malfunction.
Operation Other features Water drainage FOLLOW ME/TEMP SENSING feature(optional) NOTE:This feature can be activated from the remote control ONLY. The remote control servesas a remote thermostat allowing for the precise temperature control at its location. To activate the Follow Me/Temp Sensing feature, point the remote control towards the unit and press the Follow Me/Temp Sensing button. The remote display is actual temperature at its location.
Maintenance Safety Precautions Clean the Unit Clean the unit using a damp, lint-free cloth and mild detergent. Dry the unit with a dry, lint-free cloth. -Always unplug the unit before cleaning or servicing. -DO NOT use flammable liquids or chemicals to clean the unit. -DO NOT wash the unit under running water. Doing so causes electrical danger. -DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
Faults Diagnosis Please check the machine according to the following form before asking for maintenance: Problem Unit does not turn on when pressing ON/OFF button Possible Cause P1 Error Code Troubleshooting The Water Collection Tray is full. Turn off the unit, drain the water from the Water Collection Tray and restart the unit.
Design and Compliance Notes Design Notice In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice. Energy Rating Information The Energy Rating for this unit is based on an installation using an un-extended exhaust duct without window slider adaptor (as shown in the Installation section of this manual).
Sociable Remark When using this dehumidifier in the European countries, the following information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
CP022IU-PQ(US) 16120600000290
说明书纸张规格:210*290 材质:铜版纸105g.