INSTALLATION &OPERATIONS MANUAL MOBILE ROOM AIR CONDITIONER AUX AIR CONDITIONER CO.,LTD.
CONTENTS Safety Precaution ....................................................... 1 Parts Description ....................................................... 5 Control Panel.............................................................. 6 Operation.................................................................... 8 Accessories................................................................ 9 Installation ................................................................. 11 Maintenance ....................
Safety Precautions Troubleshooting To save the cost of a service call, please try the suggestions below to see if you can solve your problem without outside help. Air Condition Will Not Operate Causes ● ● ● ● Solutions The power switch is released. Power supply failure. The fuse is burnt. It doesn't reach the setting time for starting up. Switch on the power. Wait for the recovery of power supply. Replace the fuse by professional. Wait or eliminate the original setting.
Maintenance Safety Precautions earth leakage breaker with rated capacity must be installed to avoid possible electric shocks. ! Don’ t install air conditioner in a place where there is flammable gas or liquid. ! If the power supply cord is damaged, it must be replaced by the manufacture or its service agent or a similar qualified person. ! The specification of the fuse are printed on the circuit board, such as: AC 250V/5A, etc. ! Don't put hands or any objects into the air inlets or outlets.
Safety Precautions Installation * If the unit you bought has the pump drain outlet, as shown below, please drain in this way : Remove the pump drain plug from the back of the unit, attach the drain hose to the hole. Place the other end of the hose in the drainage way or other drain areas. WARNING ! Failure to follow the below precaution could result in electrical shock, fire or personal injury. 1.The plug must be plugged into an outlet that is properly installed and grounded. 2.
Safety Precautions Installation Install the exhaust duct into the wall WEEE Warning Meaning of crossed out wheeled dustbin: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
Parts Description Installation FRONT VIEW Screw B Control panel Air outlet Carrying Handle (both sides) 3.Carefully lower the window. Secure the vent panel in place with 4 type B screws,plus one screw for each extension. Front panel Air outlet Foam Seal REAR VIEW 4.Cut the foam seal B(non-adhesive) to the window width. Stuff the foam seal B between the glass and the window to prevent air and insects from getting into room.
Control Panel Installation There are two kinds about control panel, Fig A and Fig B, the actual shape shall prevail. FigA 2. Connect the exhaust duct to the Air outlet connector on back of the unit. Slide-in the adaptor A downwards until it is locked in place. (Fig.C) TEMP. indicator or Air outlet connector adaptor A 7 8 5 6 4 FigB 3 1 Fig.C TEMP.
Control Panel Installation 4. Guide of customer ●The customer should have a qualified power supply coincident with that printed on the tag of the air conditioner. ●Must use special circuit and efficient grounding outlet matching with the plug of the air conditioner. ●The appliance should be installed in accordance with national wiring regulation. ●The plug should be easily accessible after installation. (-) or (+) button a.
Accessories Operation WARNING Parts Failure to follow the below precaution could result in electrical shock, fire or personal injury. 1. The plug must be plugged into an outlet that is properly installed and grounded. 2. Do not use an extension cord or plug adaptor with this unit.