11
6. Features
LED display
Water pump function(for some models with water pump)
Continuous dehumidification mode
Water full protection
Timer function
Check filter function
Auto defrost, Anti-freezing control
Turbo key function and normal key function
Self-diagnosis and auto-protection function.
Wait 3 minutes before resuming operation
Auto-restart, When the power supply is interrupted and then restore, the unit automatically restore the
previous function setting.
7 .Electronic function
7.1 Electric part assembly condition that use
(1) Scope of application of voltage of the power: 115V, 60Hz, 1phase;
(2) Working environment: 5C~+35C;
(3) The humidity of electric part working environment: 30%RH~90%RH;
(4) The electric storage working temperature:-20C~+70C.
7.2 PCB working environment
(1) Tolerance of measure indoor side humidity: ±5%RH, the scope of application: 35%RH~85%RH;
(2) Tolerance of measure evaporator temperature: ±1C, the scope of application: 5C~+35C;
7.3 Protection function
(1) Time delay safety control (3 minutes).
When the compressor is stopped in operation, it needs 3 minutes delay to restart.
When the setting humidity is reached in operation, the compressor will stop, and it will not start again
within 3 minutes.
After the compressor operating, it needs a delay of more than 3minutes to stop.