Use and Care Manual

55
CONTROL P
ADS ON THE DEHUMIDIFIER
Other f
eatures 
Bucket 
Full Light
Glows 
when the bucket is ready to be 
emptied, or when the bucket is removed
or not replaced in the proper position.
When frost builds up on the evaporator coils, the 
compressor will cycle off and the fan will continue 
to run until the frost disappears.
Auto Defrost
W
ait 3 minutes before resuming operation
After 
the unit has stopped, it can not be restart 
opertation in the first 3 minutes. This is to protect 
the unit. Operation will automatically start after 
3 minutes.
Setting the Timer
 When
 the unit is on, first press the Timer 
 button, the Timer Off indicator light 
 illuminates. It indicates the Auto Stop 
 program is initiated. Press it again the 
 Time On indecator light illuminates.It 
 indicates the Auto Start is initiated.
 Press or hold the UP or DOWN pad to 
 change the Auto time by 0.5 hour incre-
 ments, up to 10 hours, then at 1 hour 
 increments up to 24 hours. The control 
 will count down the time remaining until 
 start. 
 The selected time will register in 5 seconds 
 and the system will automatically revert 
 back to display the previous humidity 
 setting.
 When the Auto start & Auto stop times are
 set, within the same program sequence, 
 TIMER ON OFF indicator lights illuminate 
 identifying both ON and OFF times are
 now programmed.
 Turning the unit ON or OFF at any time or 
 adjusting the timer setting to 0.0 will cancel
 the Auto Start/Stop function.
 When LED display window displays the
 code of P2, the Auto Start/Stop function 
 will also be cancelled.
When the unit is off, first press the Timer 
 button, the TIMER ON indicator light 
 illuminates. It indicates the Auto Start 
 program is initiated. Press it again the 
 Time Off indecator light illuminates.It 
 indicates the Auto Stop is initiated.
Check 
filter feature
The 
system starts to count the time once the fan 
motor operates. The check filter feature can be 
only activated when the accumulated operation 
time achieves 250 hours or more. The Reset 
 light(Clean filter indicator light) flashes at one time 
per second, after finishing clean the air filter, press 
the Filter pad and the Reset light(Clean filter indicator
light) goes off. 
1010
Disp
lay
Shows the set % humidity level fr
om 35% to 85% or auto 
start/stop time (0~24) while setting, then shows the actual
( 5% accuracy) room % humidity level in a range of 30%
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it 
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty 
the bucket and replace it in the right position.
E1- Unit malfunction-- Unplug the unit and plug it back in. 
If error repeats, call for service.
Auto
 Shut Off
The 
dehumidifier shuts off after 30 seconds when 
the bucket is full, or when the bucket is removed 
or not replaced in the proper position.When the 
setting humidity is reached, the unit will be shut 
off automatically. For some models,the fan motor
will continue operating.
Auto-Restart
If
 the unit breaks off unexpectedly due to the power cut, 
it will restart with the previous function setting automa-
tically when the power resumes.
EC- Unit malfuction--
  for
Please make sure whether the 
enviroment temperature is suitable for the stated 
temperature in the manual or not.If not,please operate 
the unit under the stated temperature.If the enviroment 
temperature is suitable for the stated temperature,please 
call service.