DATA SHEE T Keysight U8480 Series USB Thermocouple Power Sensors DC/10 MHz to 18/33/50/67/120 GHz
Improve your power measurement throughput Improve your power measurement throughput with the world’s fastest USB thermocouple power sensors. The Keysight Technologies, Inc. U8480 Series USB thermocouple power sensors come with a measurement speed of 900 readings/second and power linearity of less than 0.8%, providing high accuracy and stability to help you make average power measurements quickly and confidently.
Fast measurement speed Gamma correction The U8480 Series USB thermocouple power sensors offer a measurement speed of 900 readings/second (in fast mode), making them the world’s fastest USB thermocouple power sensors. This feature is especially important in high volume manufacturing, where fast measurement speed is essential to maximize production throughput and increase productivity.
Performance specifications Specification definitions There are two types of product specifications: –– Warranted specifications are specifications which are covered by the product warranty and apply over a range of 0 to 55 °C unless otherwise noted. Warranted specifications include measurement uncertainty calculated with a 95% confidence –– Characteristic specifications are specifications that are not warranted. They describe product performance that is useful in the application of the product.
U8480 Series USB Power Sensors Specifications Key specifications Frequency range Power range Power linearity1 U8481A Option 100 10 MHz to 18 GHz U8481A Option 200 DC to 18 GHz U8485A Option 100 10 MHz to 33 GHz U8485A Option 200 DC to 33 GHz U8487A Option 100 10 MHz to 50 GHz U8488A Option 100 10 MHz to 67 GHz 67 GHz to 70 GHz U8489A Option 200 DC to 120 GHz –35 dBm to 20 dBm ≤+15 dBm ± 0.50% (25 °C ± 10 °C) ± 0.55% (0 to 55 °C) >+15 to +20 dBm ± 0.55% (25 °C ± 10 °C) ± 0.
Power linearity Maximum SWR Frequency band U8481A 25 ºC ± 10 ºC DC to 10 MHz1 Frequency band 0 ºC to 55 ºC MHz1 U8485A 25 ºC ± 10 ºC 0 ºC to 55 ºC 1.11 1.14 DC to 10 1.07 1.07 10 MHz 2 to 30 MHz 1.37 1.57 10 MHz 2 to 50 MHz 1.33 1.53 >30 MHz to 50 MHz 1.14 1.16 >50 MHz to 100 MHz 1.08 1.11 >50 MHz to 2 GHz 1.08 1.11 >100 MHz to 2 GHz 1.05 1.07 >2 GHz to 12.4 GHz 1.16 1.16 >2 GHz to 12.4 GHz 1.14 1.14 >12.4 GHz to 18 GHz 1.23 1.25 >12.4 GHz to 18 GHz 1.19 1.
Zero drift and measurement noise Conditions (RH)1 Zero drift2, 3 Measurement noise2, 4 up to 70% ± 5.5 nW ± 45 nW 1. RH is the abbreviation for relative humidity. 2. Zero drift and measurement noise specifications are tested at 50 MHz. 3. Within 1 hour of warm up and after zeroing, at a constant temperature, taken over a period of 4 hours of the total measurement time. This drift is calculated based on the average of hourly drifts. 4.
Calibration factor (CF) uncertainty The typical measurement uncertainties listed are not to be taken as the maximum CF measurement uncertainties. Note: The CF uncertainty is dependent on the calibration standard’s uncertainty provided by Calibration Labs. For the exact uncertainty, refer to the individual sensor calibration report. U8481A frequency band DC to 10 10 MHz 2 25 ºC ± 3 ºC 25 ºC ± 10 ºC 0 ºC to 55 ºC MHz1 2.63% 3.30% 3.44% to 30 MHz 1.05% 1.25% 2.35% >30 MHz to 500 MHz 0.85% 0.
U8488A frequency band 25 ºC ± 3 ºC 25 ºC ± 10 ºC 0 ºC to 55 ºC 10 MHz to 50 MHz 2.04% 2.14% 2.16% >50 MHz to 100 MHz 1.94% 2.05% 2.05% >100 MHz to 2 GHz 1.98% 2.18% 2.36% >2 GHz to 12.4 GHz 2.13% 2.80% 3.56% >12.4 GHz to 18 GHz 2.24% 3.01% 3.88% >18 GHz to 26.5 GHz 2.52% 3.09% 3.89% >26.5 GHz to 50 GHz 4.66% 5.49% 6.65% >50 GHz to 67 GHz 5.14% 6.06% 7.48% >67 GHz to 70 GHz 5.70% 8.14% 9.
General specifications Acquisition Analog-to-digital converter (ADC) sampling rate 192 kHz ADC resolution 24 bits Integration time1 1.024 ms Other Current requirement 400 mA (approximately) Connector type U8481A N-Type (m), 50 Ω U8485A 3.5 mm (m), 50 Ω U8487A 2.4 mm (m), 50 Ω U8488A 1.85 mm (m), 50 Ω U8489A 1.0 mm (m), 50 Ω Cable USB 2.0 Type A to 5-pin Mini-B Interface USB 2.
General characteristics Environmental compliance Temperature Operating condition: 0 °C to 55 °C Storage condition: –40 °C to 71 °C Humidity Maximum Operating condition: 95% RH at 40 °C (non-condensing) Storage condition: Up to 90% RH at 65 °C (non-condensing) Altitude Operating and storage conditions: Up to 4.
Using the U8480 Series with the BenchVue Software Keysight BenchVue software for the PC accelerates testing by providing intuitive, multiple instrument measurement visibility and data capture with no programming necessary. You can derive answers faster than ever by easily viewing, capturing and exporting measurement data and screen shots.
System and installation requirements PC operating system Windows 10, 8 and 7 Windows 10 32-bit and 64-bit (Professional, Enterprise, Education, Home versions) Windows 8 32-bit and 64-bit (Core, Professional, Enterprise) Windows 7 SP1 and later 32-bit and 64-bit (Professional, Enterprise, Ultimate) Computer hardware Professor: 1 GHz or faster (2 GHz or greater recommended) RAM: 1 GB (32-bit) or 2 GB (64-bit) (3 GB or greater recommended) Windows XP SP3 32-bit (Professional) Processor: 600 MHz or faster
Ordering information Model Description U8481A USB thermocouple power sensor (Type-N) U8481A-100 Standard option – 10 MHz to 18 GHz U8481A-200 DC coupled option – DC to 18 GHz U8485A USB thermocouple power sensor (3.5 mm) U8485A-100 Standard option – 10 MHz to 33 GHz U8485A-200 DC coupled option – DC to 33 GHz U8487A USB thermocouple power sensor (2.4 mm) U8487A-100 Standard option – 10 MHz to 50 GHz U8488A USB thermocouple power sensor (1.
Travel kits U2000A-201 Transit case U2000A-202 Soft carrying case U2000A-203 Holster U2000A-204 Soft carrying pouch Cables (selectable during sensor purchase) U2000A-301 Power sensor cable, 5 ft (1.5 m) U2000A-302 Power sensor cable, 10 ft (3 m) U2000A-303 Power sensor cable, 16.4 ft (5 m) Cables U2031A Power sensor cable, 5 ft (1.5 m) U2031B Power sensor cable, 10 ft (3 m) U2031C Power sensor cable, 16.4 ft (5 m) U2032A BNC male to SMB female trigger cable, 50 Ω, 1.