DATA SHEE T U2000 Series USB Power Sensors The compact, low-cost alternative to conventional power measurement solutions
Why Keysight’s Power Meters and Sensors? Reliable, high-performing solutions Every power meter and sensor from Keysight Technologies, Inc. consistently delivers great results. A sure investment for many years to come Code-compatibility between power meters reduces the need for re-coding. Not only that, all Keysight power meters are backwardcompatible with most legacy power sensors.
Compact Solutions for Testing Today’s RF and Microwave Communication Systems For installation and maintenance of base stations –– Lightweight and rugged –– Simple set-up and usage –– Portable with low power consumption –– Wide dynamic and frequency ranges –– Quick and easy testing with large display of readings –– Internal trigger eliminates the problem for applications that do not have external trigger signal –– Trace display capability enables easy gate setup Find us at www.keysight.
Introducing the U2000 Series USB Power Sensors The U2000 Series enable simpler, lower-cost power measurements versus conventional power meter and sensor combinations. Now with nine high-performance models, the U2000 Series USB power sensors offer compact, high-performance solutions for today’s CW and modulated signals.
Introducing the U2000 Series USB Power Sensors (Continued) Faster production testing of multiple channels Transform your signal generators and spectrum analyzers into accurate power meters The U2000 Series’ fast measurement speed helps reduce test time. This, coupled with the capability to enable monitoring of more than 20 channels simultaneously, is an advantage in the production line where efficiency is of utmost priority.
Take a Closer Look LED indicator for PC communication Built-in triggering port for synchronization with external instruments or events Small and lightweight build Secure locking mechanism USB 2.0-compliant cable for connection to PC or other instruments Diode-based sensors frequently rely on the application of correction factors to extend their dynamic range beyond their square-law region, typically in the range of –70 to –20 dBm.
Specifications Specifications contained in this chapter are valid ONLY after proper calibration of the power sensor and apply to continuous wave (CW) signals unless otherwise stated. The recommended calibration interval for this product is one year. Specifications apply over a temperature range 0 to +55 °C unless otherwise stated. Specifications quoted over a temperature range of 25 °C ± 10 °C apply to a relative humidity of 15% to 75% and conform to the standard environmental test conditions.
Specifications (Continued) Typical SWR for U2000A sensor (25 °C ± 10 °C) Typical SWR for U2001A sensor (25 °C ± 10 °C) Typical SWR for U2002A sensor (25 °C ± 10 °C) Find us at www.keysight.
Specifications (Continued) Typical SWR for U2004A sensor (25 °C ± 10 °C) Typical SWR for U2002H sensor (25 °C ± 10 °C) Typical SWR for U2000H sensor (25 °C ± 10 °C) Typical SWR for U2000B sensor (25 °C ± 10 °C) Typical SWR for U2001H sensor (25 °C ± 10 °C) Typical SWR for U2001B sensor (25 °C ± 10 °C) Find us at www.keysight.
Specifications (Continued) Switching point The U2000 Series power sensors have two measurement paths: a low power path and a high power path, as shown in the table below. Models U2000/1/2/4A U2000/1/2H U2000/1B AUTO (default) range –60 to +20 dBm –50 to +30 dBm –30 to +44 dBm Low power path –60 to –7 dBm –50 to +3 dBm –30 to +23 dBm High power path –7 to +20 dBm +3 to +30 dBm +23 to +44 dBm Switching point –7 dBm +3 dBm +23 dBm Each power sensor automatically selects the proper power level path.
Specifications (Continued) Typical power accuracy at 25 °C for U2000/1/2/4A sensors 1, 2 Typical power accuracy at 25 °C for U2000/1B sensors 1, 2 Typical power accuracy at 25 °C for U2000/1/2H sensors 1, 2 1. Measurement uncertainty ≤ 1.9%. At room temperature and excluding power level dependent terms (zero set, drift, and noise).
Specifications (Continued) Zero set, zero drift, and measurement noise Average only mode Power range 1 U2000/1/2A –60 to –35 dBm –38 to –15 dBm –20 to –6.5 dBm –7.5 to –2 dBm –4 to 15 dBm 10 to 20 dBm U2004A –60 to –35 dBm –38 to –15 dBm –20 to –6.5 dBm –7.5 to –2 dBm –4 to 15 dBm 10 to 20 dBm U2000/1/2H –50 to –25 dBm –28 to –5 dBm –10 to 3.5 dBm 2.5 to 8 dBm 6 to 25 dBm 20 to 30 dBm U2000/1B sensors –30 to –5 dBm –8 to 15 dBm 10 to 23.5 dBm 22.
Specifications (Continued) Normal mode Range 1 U2000/1/2A –38 to –15 dBm –20 to –6.5 dBm –7.5 to –2 dBm –4 to 15 dBm 10 to 20 dBm U2000/1/2H –28 to –5 dBm –10 to 3.5 dBm –2.5 to 8 dBm 8 to 25 dBm 20 to 30 dBm U2000/1B –8 to 15 dBm 10 to 23.5 dBm 22.5 to 28 dBm 26 to 44 dBm 1. 2. 3. 4.
Specifications (Continued) Effect of time-gating and averaging on normal mode measurement noise: The normal mode measurement noise wil depend on the gate length (time-gated period in second) and the number of averages. The noise can be approximately calculated with the following equations. If the gate length is < 2.73 µs, use Equation 1: Noise = Noise per sample × 1 Number of averages Otherwise, use Equation 2: Noise = Noise per sample × 1 Number of averages × ( 4 Gate length/(0.
Specifications (Continued) Settling time Manual filter, 10-dB decreasing power step (not across switching points). Number of averages Settling time (s) 1 2 4 8 16 32 64 128 256 512 1024 Normal speed x2 speed 0.045 0.042 0.09 0.05 0.17 0.09 0.34 0.17 0.66 0.34 1.3 0.66 2.6 1.3 5.2 2.6 10.4 5.2 20.9 10.4 41.9 20.9 Auto filter, default resolution, 10-dB decreasing power step x2 speed Normal speed 45 ms 45 ms 82 ms 1.3 s Typical settling times 1.5 s 450 ms 1.
Specifications (Continued) Calibration factor and reflection coefficient Calibration factor (CF) and reflection coefficient (Rho) data is unique to each sensor. The CF corrects for the frequency response of the sensor. The reflection coefficient (Rho or ρ) relates to the SWR based on the following formula: SWR = 1 + ρ 1–ρ Maximum uncertainties of the CF data are listed in the following table. There is only one set of CF data used for both high and low power paths of each sensor.
Specifications (Continued) Trigger Internal trigger Resolution Level accuracy Jitter External TTL trigger input Impedance Trigger low Trigger high Minimum trigger pulse width Minimum trigger repetition period Trigger latency Trigger delay Range Resolution Trigger hold-off Range Resolution Trigger hysteresis Range Resolution 1. 0.1 dB ± 1 dB ± 1 µs 50 Ω or 1 kΩ 1 < 1.1 V > 1.9 V 35 ns 80 ns 11 µs ± 2 µs –0.15 to + 0.15 s 1 µs 1 µs to 400 ms 1 µs 0 to +3 dB 0.
Specifications (Continued) General specifications Physical characteristics Dimensions (LxWxH) Weight Operating environment Temperature Humidity Altitude Pollution Storage and shipment Environment Temperature Humidity Altitude Pollution Other Current requirement Connector Cable Programmability Safety and EMC compliance Calibration 1 Warranty 1 Compatible instruments Mechanical characteristic 1. U2000/1/4A U2002A U2000/1B U2000/1H U2002H U2000/1/4A U2002A U2000/1B U2000/1H U2002H 163.75 mm x 46.
Using the U2000 Series with the BenchVue Software Keysight BenchVue software for the PC accelerates testing by providing intuitive, multiple instrument measurement visibility and data capture with no programming necessary. You can derive answers faster than ever by easily viewing, capturing and exporting measurement data and screen shots. Digital meter, analog meter and datalog view.
System and Installation Requirements PC operating system Windows 10, 8 and 7 Computer hardware Windows XP SP3 32-bit (Professional) Interfaces Display resolution Windows 10 32-bit and 64-bit (Professional, Enterprise, Education, Home versions) Windows 8 32-bit and 64-bit (Core, Professional, Enterprise) Windows 7 SP1 and later 32-bit and 64-bit (Professional, Enterprise, Ultimate) Professor: 1 GHz or faster (2 GHz or greater recommended) RAM: 1 GB (32-bit) or 2 GB (64-bit) (3 GB or greater recommended) Pr
Ordering Information Power sensors Models U2000A Description 10 MHz to 18 GHz USB sensor Power range –60 to +20 dBm Connector type N-type male, 50 Ω U2000B 10 MHz to 18 GHz USB sensor –30 to +44 dBm N-type male, 50 Ω U2000H 10 MHz to 18 GHz USB sensor –50 to +30 dBm N-type male, 50 Ω U2001A U2001B 10 MHz to 6 GHz USB sensor 10 MHz to 6 GHz USB sensor –60 to +20 dBm –30 to +44 dBm N-type male, 50 Ω N-type male, 50 Ω U2001H 10 MHz to 6 GHz USB sensor –50 to +30 dBm N-type male, 50 Ω U2002A
Ordering Information (Continued) Accessories, calibration and documentation options. Cables U2031A U2031B Description USB 2.0 Type A to 5-pin Mini-B cable with secure locking mechanism, 1.5 m (5 ft) USB 2.0 Type A to 5-pin Mini-B cable with secure locking mechanism, 3.0 m (10 ft) U2031C U2032A Travel kits U2000A-201 U2000A-202 U2000B-201 U2000A-204 Hanging kit USB 2.0 Type A to 5-pin Mini-B cable with secure locking mechanism, 5.0 m (16.4 ft) BNC (m) to SMB (f) trigger cable, 1.