Keysight Technologies U1210 Series Handheld Clamp Meters Handle big currents – more safely Data Sheet
Introduction Measurements of electrical distribution cables can be challenging and risky. For cables up to two inches in diameter, the Keysight Technologies, Inc. U1210 Series handheld clamp meters enable high-current measurements without breaking the circuit. Unlike most clamp meters, they also include DMM capabilities—resistance, capacitance, frequency and temperature—to simplify troubleshooting during installation and maintenance.
03 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Key Measurements Measure current easily and accurately Keysight U1210 Series handheld clamp meters come with clamp opening of 52 mm/2 inches and high current measurement capability of up to 1000 A (AC, DC, AC+ DC). With the large jaw size, these handhelds simplify current measurements for thick cables. Clamp on with the U1210 Series and get convenience, versatility and the ability to handle big currents—safely.
04 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Take a Closer Look Large jaw opening of 2 inches to test thick current sources Capacitance/Diode measurement Max or Min recording capability Temperature and audible continuity functions High measurement capability of up to 1000 A for AC, DC or AC+DC Peak hold function for in-rush current testing Large LCD display with maximum reading of 4000 counts Manual or auto ranging
05 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet General Specifications Title Specification Dimension –– U1211A: 106 mm (W) X 273 mm (L) X 43 mm (H) –– U1212A and U1213A: 106 mm (W) X 260 mm (L) X 43 mm (H) Net Weight –– U1211A: 625 grams with batteries included –– U1212A and U1213A: 525 grams with batteries included Display 4 digits with maximum reading 4,100 counts. The 12 Segments analog bar graph and full annunciator. Automatic polarity indication.
06 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1211A Accuracy is given as ± (% of reading + number of least significant digits) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H. ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale.
07 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1211A (continued) Capacitance Range Resolution Accuracy Overload protection 400 µF 0.1 µF 2%+4 4000 µF 1 µF 3%+4 1000 V R.M.S. for circuits < 0.3 A of short circuit current –– The accuracy is based on film capacitor or better and use Relative mode to zero residual value AC current Range Resolution Accuracy *N1 45~65 Hz 65~400 Hz 400 Hz~1 kHz 40 A 0.01 A 1.0 % + 10 1.0 % + 10 3.
08 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1211A (continued) Frequency (AC coupling) Range Resolution 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 999.9 kHz 0.1 kHz Accuracy Minimum frequency 0.2 % + 3 10 Hz –– Overload protection: 1000 V; < 20,000,000 V x Hz Sensitivity Frequency sensitivity Range Minimum sensitivity (R.M.S.
09 | Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1212A Accuracy is given as ± (% of reading + number of least significant digits) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H. ACV/ ACA specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1212A (continued) Capacitance Range Resolution Accuracy Overload protection 400 µF 0.1 µF 2%+4 4000 µF 1 µF 3%+4 1000 V R.M.S. for circuits < 0.3 A of short circuit current –– The accuracy is based on film capacitor or better and use Relative mode to zero residual value DC current Range Resolution Accuracy 40 A 0.01 A 1.5 % + 15 400 A 0.1 A 1.5 % + 3 1000 A 1A 2.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1212A (continued) Frequency (AC coupling) Range Resolution 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 999.9 kHz 0.1 kHz Accuracy Minimum frequency 0.2 % + 3 10 Hz –– Overload protection: 1000 V Sensitivity Frequency sensitivity Range Minimum sensitivity (R.M.S.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1213A Accuracy is given as ± (% of reading + number of least significant digits) at 23 °C ± 5 °C, with relative humidity less than 80 % R.H. AC voltage, AC current, AC+DC voltage, AC+DC current specifications are ac coupled, true R.M.S. and are valid from 5 % of range to 100 % of range. The crest factor may be up to 3.0 at full-scale except the 1000 V and 1000 A ranges where these are 1.5 at full scale.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1213A (continued) Diode check/audible continuity test Range Resolution Accuracy Test current Open voltage Diode 0.001 V 0.5 % + 2 Approximately 0.8 mA < +3.1 V –– Overload protection: 1000 V R.M.S. for circuits < 0.3 A of short circuit current –– Built-in buzzer sounds when reading is below 50 mV approximately and single tone for normal forward-biased diode or semiconductor junction as 0.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1213A (continued) AC current Accuracy *N1 Range Resolution 45 ~ 65 Hz 65 ~ 200 Hz 200 ~ 300 Hz 300 ~ 400 Hz 40 A 0.01 A 2.0 % + 10 3.0 % + 10 3.5 % + 10 6.5 % + 10 400 A 0.1 A 2.0 % + 5 3.0 % + 5 3.5 % + 5 6.5 % + 5 1000 A 1A 2.0 % + 5 3.0 % + 5 3.5 % + 5 6.5 % + 5 Maximum overload 1000 A R.M.S.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Electrical Specifications for U1213A (continued) Frequency (AC coupling) Range Resolution 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 99.99 kHz 0.01 kHz 999.9 kHz 0.1 kHz Accuracy Minimum frequency 0.2 % + 3 10 Hz –– Overload protection: 1000 V; < 20,000,000 V x Hz Sensitivity Frequency sensitivity Range Minimum sensitivity (R.M.S.) Maximum input for specified accuracy of AC 45 Hz~2 kHz 10 Hz~200 kHz 4V 0.
| Keysight | U1210 Series Handheld Clamp Meters – Data Sheet Ordering Information Standard shipped accessories –– Test leads –– 4-mm probes –– Soft carrying case –– Quick Start Guide –– Certificate of Calibration (CoC) Optional accessories U1168A Standard test lead kit U1162A Alligator clips U1175A Soft carrying case U1186A K-type thermocouple and adapter U1177A Infrared (IR)-to-Bluetooth Adapter Did you know? Ensure that the clamp meter measures only one conductor at a time.
| Keysight | U1210 Series Handheld Clamp Meters - Data Sheet Evolving Since 1939 Our unique combination of hardware, software, services, and people can help you reach your next breakthrough. We are unlocking the future of technology. From Hewlett-Packard to Agilent to Keysight. myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. http://www.keysight.