Datasheet
04 | Keysight | Handheld Tools For Electronic, Electrical and Industrial Process Testing – Brochure
Specications of the U5850 series TrueIR thermal imagers, continued
Measurements and alarm
Measurements Center spot, 3x moveable spots, max/min tracking, delta temperature, 3x moveable boxes (with min/max/avg)
Color alarm
Alarm zones
Background
High/low temperature in all areas
Above/below/inside/outside
Hot white/Hot black
Supplemental characteristics
Storage device Supports up to 32 GB SDHC memory card with class 4 and above
Image format
IR image
Visible image
Radiometric JPEG
JPEG
Image logging Logs IR, visible or fusion images at a dened interval (7 to 3600 seconds)
State storage memory Three user-congurable stored states
Tagging/annotation 3 photo tags, note tag, note tag from template (downloadable from the Keysight Web site)
I/O USB 2.0 mass storage
NTSC/PAL via video RCA cable
Language English, French, German, Italian, Japanese, Korean, Portuguese, Russian, Spanish, Simplied Chinese, Traditional Chinese
Built-in quick start tutorial Available
Product characteristics
Power supply
Power adapter Line voltage range: 50/60 Hz, 100 – 240 VAC (Auto/Universal voltage), 1.2 A
MAINS supply voltage uctuations not to exceed ±10% of the nominal voltage
Output voltage: 12 VDC, 3 A
Installation Category I (Isolated ELV supply source – connected to MAINS through an AC/DC power adapter)
Battery Li-ion rechargeable battery, 7.4 VDC, 2500 mAh
Operating time: 4 hours
Display 3.5” TFT
Visible camera 3.1 MP
Built-in LED torch Available
lim Class 2
Warm-up time 2 minutes
Operating environment
Temperature –15 to 50 °C
Humidity 50% RH to 95% RH at 40 °C
Storage compliance
Temperature –40 to 70 °C
Humidity 95% RH at 40 °C
Altitude Up to 2000 m
Pollution degree 2
Safety compliance Laser safety: IEC 60825-1/EN 60825-1 (Laser Class 2)
IEC 61010-1/EN 61010-1
EMC compliance IEC 61326-1/EN61326-1
CISPR11/EN55011, Group 1 Class A
Canada: ICES/NMB-001: Issue 4, June 2006
Australia/New Zealand: AS/NZS CISPR 11
Shock Tested to IEC 60068-2-27 Ed. 3.0
Vibration Tested to IEC 60068-2-6
Tripod mount thread ISO 1222:2010 Standard screw thread, 1/4 - 20 UNC
Drop test 2 m
Protection class 2
IP rating IP 54
Dimension (W x H x D) 95 × 250 × 85 mm
Weight 0.746 kg (with battery)
Calibration cycle 1 year
1. Minimum distance with accuracy, 10 cm to 50 cm: ± 4 °C or ± 4%
For complete specifications, please refer to data sheet 5991-4297EN