Datasheet
21 | Keysight | Handheld Tools For Electronic, Electrical and Industrial Process Testing – Brochure
Model no. U1602B U1604B U1610A U1620A
Vertical system: scope channels
Bandwidth (–3 dB) 20 MHz 40 MHz 100 MHz 200 MHz
DC vertical gain accuracy 5 mV/div to 20 mV/div: ± 5% full scale
50 mV/div to 100 V/div: ± 3% full scale
± 4% of full scale
Full scale is equivalent to 8 div
Acquisition: scope channels
Maximum sample rate
Single channel operation
Dual channel operation
200 MSa/s interleave
100 MSa/s each channel
1 GSa/s interleave
500 MSa/s each channel
2 GSa/s interleave
1 GSa/s each channel
Vertical resolution 8-bits 8-bits
Maximum recording length
Single channel operation
Dual channel operation
125 Kpts 125 Kpts 120 Kpts interleave
60 Kpts each channel
2 Mpts interleave
1 Mpts each channel
Vertical system: scope channels
Rise time < 17.5 ns <8.8 ns 3.50 ns typical 1.75 ns typical
Maximum input CAT III 300 Vrms (up to 400 Hz)
from terminal to ground
CAT III 600 Vrms (with 10:1 probe)
CAT III 300 Vrms (direct / 1:1 probe)
Bandwith limit N/A 10 KHz and 20 MHz (selectable)
Channel-to-channel isolation N/A Yes, CAT III 600 V Vrms
Probe attentuation factors 1x, 10x, 100x 1x, 10x, 100x
Horizontal system
Range 50 ns to 50 s/div 10 ns to 50 s/div 5 ns/div to 50 s/div 2 ns/div to 50 s/div
Modes Main, XY, roll Main, zoom, XY, roll
Trigger system
Sources Channel 1 and Channel 2 Channel 1, Channel 2, External
Modes Auto, normal, single Normal, Single, Auto
Types Edge, Pattern, Pulse Width, Video Edge, Glitch, TV, Nth Edge, CAN, LIN
Auto measurements Peak-to-peak, maximum, minimum, amplitude, top, base,
+overshoot, –overshoot, preshoot, RMS, mean and one
cycle mean, Frequency, period, +width, –width, and +duty
cycle and –duty cycle on any channel. Rise time, fall time,
delay and phase shift
Delay, duty cycle (+/–), fall/rise time, frequency, period,
phase shift, T-max,T-min, width (+/–), amplitude, average,
base, crest, cycle mean, maximum,minimum, overshoot,
peak-to-peak, preshoot, standard deviation, top,
Vrms (AC/DC), active/apparent/reactive power, power factor
Waveform math functions CH1 + CH2, CH1 – CH2, CH2 – CH1 CH1 + CH2, CH1 – CH2, CH2 – CH1, CH1 × CH2, CH1/CH2,
CH2/CH1, d/dt (CH1),d/dt (CH2), ∫(CH1)dt, ∫(CH2)dt, FFT
Digital multimeter measurement
Voltage AC/DC range 600 mV to 600 V 1000 mV to 1000 V
Resistance range 600 Ω to 60 MΩ 1000 Ω to 100 MΩ
Capacitance range 60 nF to 300 uF 1000 nF to 10 mF
Diode range 1 V 1 V
Temperature range 600 °C –50 to 1000 °C
Frequency N/A 100 Hz to 1000 KHz
AC current range 60 A N/A
Measurement characteristic
Resolution 6,000 counts 10,000 counts
Continuity Beeper < 60 W in 600 W range Continuous beep when resistance < 10 Ω
Datalogger Yes Yes
Digital Oscilloscopes
Our handheld scopes are designed to be used across a wide range of applications and troubleshooting tasks.
Each model comes with different specications to tailor to your needs, and are safety certied for safer measurements.