Datasheet

06 | Keysight | N8700 Series System DC Power Supplies - Data Sheet
Performance Specications (continued)
1. Minimum voltage is guaranteed to maximum 0.2% of rated output voltage.
2. Minimum current is guaranteed to maximum 0.4% of rated output current.
3. 20 MHz
4. 5 Hz - 1 MHz
5. From no-load to full-load, constant input voltage. Maximum drop in remote sense.
6. For load voltage change equal to the unit voltage rating, constant input voltage
7. Single-phase and 3-Phase 208 V models: 170~265 VAC, constant load. 3-Phase 400 V models: 342~460 VAC, constant load.
8. The constant current programming readback and monitoring accuracy does not include the warm-up and load regulation thermal drift.
9. Time for output voltage to recover within 0.5% of its rated output for a load change 10 - 90% of rated output current, local sense.
N8737A N8738A N8739A N8740A N8741A N8742A
DC output ratings
Voltage
1
60 V 80 V 100 V 150 V 300 V 600 V
Current
2
55 A 42 A 33 A 22 A 11 A 5.5 A
Power 3300 W 3360 W 3300 W 3300 W 3300 W 3300 W
Output ripple and noise
CV
p-p
3
60 mV 80 mV 100 mV 100 mV 300 mV 500 mV
CV
rms
4
8 mV 25 mV 25 mV 25 mV 100 mV 120 mV
Load effect
CV load regulation
5
14 mV 17 mV 20 mV 27.5 mV 50 mV 95 mV
CC load regulation
6
16 mA 13.4 mA 11.6 mA 9.4 mA 7.2 m A 6.1 mA
Source effect
CV line regulation
7
8 mV 10 mV 12 mV 17 mV 32 mV 62 mV
CC line regulation
7
7.5 mA 6.2 mA 5.3 mA 4.2 mA 3.1 mA 2.6 mA
Programming accuracy
Voltage
1
0.05% + 30 mV 40 mV 50 mV 75 mV 150 mV 300 mV
Current
2, 8
0.1% + 110 mA 84 mA 66 mA 44 mA 22 mA 11 mA
Measurement accuracy
Voltage 0.1% + 60 mV 80 mV 100 mV 150 mV 300 mV 600 mV
Current
8
0.1% + 165 mA 126 mA 99 mA 66 mA 33 mA 16.5 mA
Load transient recovery time
Time
9
<1 ms <1 ms <1 ms <2 ms <2 ms <2 ms