Datasheet
N6731B-N6792A DC Power & Load Modules
N6700C-N6705C Mainframes
42 Specifications Guide
Supplemental Characteristics
N6781A / N6782A
N6784A
N6785A / N6786A
Minimum Current and Voltage Compliance limits:
20 V range Voltage Priority mode 10 mA 10 mA 8 mA
10 V & 15 V ranges Voltage Priority mode - - 8 mA
6 V range Voltage Priority mode 20 mA 20 mA 8 mA
8 A, 6.7 A, 5 A, & 4 A ranges Current Priority - - 20 mV
3 A range Current Priority mode 10 mV 10 mV -
1 A range Current Priority mode 20 mV 20 mV -
Programming Range & Resolution:
Voltage, 20 V range 0 to 20.4 V; 200 μV -20.4 V to 20.4 V; 200 μV 0 to 20.4 V; 200 μV
Voltage, 15 V range - - 0 to 15.3 V; 200 μV
Voltage, 10 V range - - 0 to 10.2 V; 200 μV
Voltage, 6 V range 0 to 6.12 V; 60 μV -6.12 V to 6.12 V; 60 μV 0 to 6.12 V; 200 μV
Voltage, 600 mV range 0 to 612 mV; 6 μV -612 mV to 612 mV; 6 μV -
Current, 8 A range - - -8.16 A to 8.16 A; 75 μA
Current, 6.7 A range - - -6.83 A to 6.83 A; 75 μA
Current, 5 A range - - -5.1 A to 5.1 A; 75 μA
Current, 4 A range - - -4.08 A to 4.08 A; 75 μA
Current, 3 A range -3.06 A to 3.06 A; 25 μA -3.06 A to 3.06 A; 25 μA -
Current, 1 A range
-1.02 A to 1.02 A; 25 μA
-1.02 A to 1.02 A; 25 μA
-
Current, 300 mA range -306 mA to 306 mA; 3 μA - -
Current, 100 mA range - -102 mA to 102 mA; 1 μA -
Current, 10 mA range - -10.2 mA to 10.2 mA; 0.1 μA -
Resistance for 20 V range
NOTE 1
-40mΩ to +1Ω; 0.5mΩ - -40mΩ to +1Ω; 0.17mΩ
Resistance for 15 V, & 10 V ranges
NOTE 1
- - -40mΩ to +1Ω; 0.17mΩ
Resistance for 6 V range
NOTE 1
-40mΩ to +1Ω; 0.25m - -40mΩ to +1Ω; 0.17mΩ
Programming Accuracy Temperature Coefficient per °C:
Voltage, 20 V range 0.002% +120uV 0.002% +120uV 0.0025% +200uV
Voltage, 10 V & 15 V ranges - - 0.0025% +200uV
Voltage, 6 V range 0.0015% +40uV 0.0015% +40uV 0.0025% +200uV
Voltage, 600 mV range 0.0015% +10uV 0.0015% +10uV -
Current, 8 A, 6.7 A, 5 A, & 4 A ranges - - 0.0025% +150uA
Current, 3 A & 1 A ranges 0.0025% +22uA 0.0025% +22uA -
Current, 300 mA range 0.0025% +14uA - -
Current, 100 mA range - 0.0025% +1uA -
Current, 10 mA range - 0.0025% +0.5 μA -
Measurement Resolution:
Voltage, 20 V range 200 μV 200 μV 200 μV
Voltage,1 V range 10 μV 10 μV -
Voltage, 100 mV range 1 μV 1 μV -
Auxiliary Voltage Measurement Input
NOTE 1
800 μV - 800 μV
Measurement Resolution
(continued)
Current, 8 A range
Current, 3 A range
Current, 100 mA range
Current, 1 mA range
Current, 10 μA range
-
25 uA
1 uA
10 nA
0.1 nA
-
25 uA
1 uA
10 nA
0.1 nA
75 uA
-
1 uA
10 nA
-