Datasheet

N6731B-N6792A DC Power & Load Modules
N6700C-N6705C Mainframes
26 Specifications Guide
Supplemental Characteristics (continued)
N6751A / N6752A
N6753A / N6755A
N6754A / N6756A
Down-programming Settling Time with no load:
(Time from start of voltage change to 0.1% of full scale value)
Small voltage step 10 V to 0 V 6 V to 0 V/10 V to 0 V 15 V to 0 V/29 V to 0 V
Time
0.45 ms
0.8 ms/1.3 ms
0.8 ms/1.5 ms
Large voltage step 50 V to 0 V 20 V to 0 V 60 V to 0 V
Time
1.4 ms
2 ms
2.3 ms
Down-programming Time with Capacitive load:
(Time from start of voltage change to output voltage < 0.5 V)
Small voltage step 10 V to 0 V 6 V to 0 V/10 V to 0 V 15 V to 0 V/29 V to 0 V
Time
2.1 ms
2.2 ms/4.5 ms
2.3 ms/5.5 ms
Large voltage step 50 V to 0 V 20 V to 0 V 60 V to 0 V
Time
11 ms
8.5 ms
10 ms
Capacitive load
NOTE 3
1000 µF
4700 µF
680 µF
Down-programming Capability:
Continuous power 7 W 12.5 W 12.5 W
Peak current 7 A 15 A 6 A
Over-voltage Protection:
Accuracy 0.25% + 0.25 V 0.25% + 0.15V 0.25% + 0.3V
Accuracy with Option 761 0.25% + 0.25 V 0.25% + 0.45V 0.25% + 0.6V
Accuracy with Option 760 - 0.25% + 0.45V 0.25% + 0.6V
Maximum setting 55 V 22 V 66 V
Response time
50 µs from occurrence of over-voltage condition to start of output shutdown
Output Ripple and Noise:
(PARD)
CC rms: 2 mA 10 mA 4 mA
Common Mode Noise:
(from 20 Hz 20 MHz; from either output to chassis)
rms
500 µA 500 µA 750 µA
peak-to-peak < 2 mA < 2 mA < 3 mA
Remote Sense Capability:
Outputs can maintain specifications with up to a 1-volt drop per load lead.
The load lead drop reduces the maximum available voltage at the load.
Series and Parallel Operation:
Identically rated outputs can be operated directly in parallel
or can be connected for straight series operation..
Minimum Output Turn-On Delay:
(Time from when any Output On command is received until the output starts
turning on)
Without relay option 25 ms 18 ms 18 ms
With relay Option 760 51 ms 44 ms 44 ms
1
Correction On compensates for current flowing into the output capacitor during voltage transients.
2
Stated values apply when the load resistance is at or close to zero. To determine the frequency for larger resistance values, refer to the
User’s Guide under “Measurement System Bandwidth”.
3
Modules can discharge the specified capacitive load from full scale to 0V at a rate of 4 times/second.