Datasheet
N6731B-N6792A DC Power & Load Modules
N6700C-N6705C Mainframes
Specifications Guide 63
Supplemental Characteristics (continued)
N6700B, N6701A, N6702A
N6700C, N6701C, N6702C
N6705B, N6705C
Regulatory Compliance:
EMC
Safety
Complies with European EMC Directive for test and measurement products.
IEC/EN 61326-1; CISPR 11, Group 1, class A; AS/NZS CISPR 11; ICES/NMB-001
Complies with Australian standard and carries the RCM mark.
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme NMB-001 du Canada.
Complies with European Low Voltage Directive and carries the CE-marking.
Conforms to US and Canadian safety standards.
Environmental Conditions
Operating environment
Temperature range
Relative humidity
Altitude
Storage temperature
Indoor use, installation category II (for AC input), pollution degree 2
0°C to 55°C (output current is derated 1% per °C above 40°C ambient temperature)
Up to 95%
Up to 2000 meters
-30°C to 70°C
Acoustic Noise Declaration:
This statement is provided to
comply with the requirements of
the German Sound Emission
Directive, from 18 January 1991.
Sound Pressure Lp, <70 dB(A), At Operator Position,
Normal Operation, According to EN 27779 (Type Test).
Schalldruckpegel Lp <70 dB(A), Am Arbeitsplatz,
Normaler Betrieb, Nach EN 27779 (Typprüfung).
Output Terminal Isolation:
Maximum rating No output terminal may be more than ±240 VDC from any other terminal or chassis
ground.
N6781A/N6785A Note
When using the AUX measurement input terminals on Models N6781A/N6785A, no
output or input terminal may be more than ±60 VDC from any other terminal and
chassis ground.
AC Input:
Input Ratings
Input Ranges
Power Consumption
Power Factor (Note 1)
Fuse
~ 100 VAC – 240 VAC; 50/60/400Hz
86–264 VAC; 47–63Hz; 380–420 Hz
1000 VA (N6700B/C)
1440 VA (N6701A/C)
1440 VA (N6702A/C @ < 180 VAC input)
2200 VA (N6702A/C @ > 180 VAC input)
0.99 @ nominal input and rated power
Internal fuse - not customer accessible.
~ 100 VAC – 240 VAC; 50/60/400Hz
86–264 VAC; 47–63Hz; 380–420 Hz
1440 VA
0.99 @ nominal input and rated power
Internal fuse - not customer accessible.
N6702A/C Note
AC mains circuits rated at 100-180 VAC
cannot
supply enough current to power the
N6702 mainframe when operated at its full rated power. When connected to a 100-
180 VAC mains, internal circuits will limit the power to modules to 600 W maximum.
Net Weight: (typical)
Mainframe with 4 modules
Single-wide module
Double-wide module
N6700B/C 12.73 kg / 28 lbs
N6701A/C 11.82 kg / 26 lbs
N6702A/C 14.09 kg / 31 lbs
1.23 kg / 2.71 lbs
2.1 kg / 4.63 lbs
16 kg / 35 lbs
1.23 kg / 2.71 lbs
2.1 kg / 4.63 lbs
Dimensions:
Refer to the outline diagrams on the following page.
Note 1: Under full load at 400 Hz, power factor drops from 0.99 @ 120 VAC to as low as 0.76 @ 265 VAC and degrades further with no load