Datasheet

N6731B-N6792A DC Power & Load Modules
N6700C-N6705C Mainframes
Specifications Guide 21
Output Quadrant Characteristic
Arbitrary Waveform Generator Maximum Bandwidth
NOTE
The information in this section only applies when the power modules are
installed in a Keysight N6705 DC Power Analyzer.
The following tables characterize the maximum bandwidth of the
arbitrary waveform generator. The maximum bandwidth is based on a
sine wave into a resistive load and apples to any output current. The
following definitions apply in the frequency tables:
V p-p =
Voltage peak-to-peak
3 dB max. =
Max. frequency where the voltage drops to 3 dB below its setting
6 dB max. =
Max. frequency where the voltage drops to 6 dB below its setting
THD 3 dB =
The total harmonic distortion at 3 dB max. frequency
THD 6 dB =
The total harmonic distortion at 6 dB max. frequency
Voltage
3 dB max
THD 3 dB
6 dB max
THD 6 dB
N6731B & N6741B
0.1 Vp-p 175 Hz 1.0% 260 Hz 3.0%
0.1 Vp-p 125 Hz 1.0% 175 Hz 3.0%
0.3 Vp-p 75 Hz 6.0% 100 Hz 6.0%
0.5 Vp-p 40 Hz 9.0% 55 Hz 9.0%
5.0 Vp-p 20 Hz 10% 37 Hz 10%
N6732B & N6742B
0.1 Vp-p 125 Hz 1.0% 200 Hz 3.0%
0.2 Vp-p 125 Hz 1.0% 180 Hz 3.0%
0.4 Vp-p 75 Hz 6.0% 100 Hz 6.0%
0.8 Vp-p 40 Hz 8.5% 60 Hz 8.5%
8.0 Vp-p 20 Hz 10% 37 Hz 10%
Current
+ rated
current
0
Voltage
+ rated
voltage
maximum
power