Datasheet
N6731B-N6792A DC Power & Load Modules
N6700C-N6705C Mainframes
8 Specifications Guide
Power Module Differences: Keysight N6700C Modular Power Systems
Keysight N6731B–N6777A Differences
Feature
DC Power
High-Performance
Precision
(
●
= available)
N673xB, N674xB,
N677xA
N675xA
N676xA
50 W output rating N6731B – N6736B N6751A N6761A
100 W output rating N6741B – N6746B N6752A N6762A
300 W output rating N6773A – N6777A N6753A, N6754A N6763A, N6764A
500 W output rating N6755A, N6756A N6765A, N6766A
Output disconnect relays Option 761 Option 761 Option 761
Output disconnect/polarity reversal relays
NOTE 1
Option 760 Option 760 Option 760
Autoranging output capability
●
●
Voltage or current turn-on priority N6761A, N6762A
Precision voltage and current measurements
●
Low voltage and low current output range N6761A, N6762A
Low voltage and low current measurement range
●
200 microampere measurement range
NOTE 2
Option 2UA
Simultaneous voltage and current measurements
●
SCPI command output list capability
NOTE 3
Option 054 Option 054
●
SCPI command array readback
NOTE 3
Option 054 Option 054
●
SCPI command programmable sample rate
NOTE 3
Option 054 Option 054
●
SCPI command external data logging
NOTE 3
Option 054 Option 054
●
Double-wide (occupies 2 channel locations) N6753A – N6756A N6763A – N6766A
1
Option 760 limits the output current to 10A maximum on Models N6742B and N6773A.
Option 760 is not available on Models N6741B, N6751A, N6752A, N6761A, and N6762A.
2
Option 2UA.is only available on Models N6761A and N6762A. It includes Option 761.
3
Only available when using the remote interfaces; not from the front panel.