Datasheet

Page 8
Find us at www.keysight.com
Characteristics and specications
Model number N2750A N2751A N2752A
Probe bandwidth* (–3 dB) 1.5 GHz 3.5 GHz 6 GHz (warranted),
7 GHz (typical)
Rise time, probe only (10-90%) 233 psec 100 psec 58.3 psec
System bandwidth
(with Keysight oscilloscope)
1 GHz (with Keysight’s 1 GHz
Inniium/InniiVision oscilloscope)
2.5 GHz (with Keysight’s 2.5 GHz
Inniium oscilloscope)
4/6 GHz (with Keysight’s 4/6 GHz
Inniium oscilloscope)
Input resistance (@DC)* 200 kΩ ± 2 % (differential mode)
100 kΩ ± 2 % (single-ended mode)
50 kΩ ± 2 % (common mode)
Input capacitance 700 fF (with browser)
Attenuation ratio (@DC) 2:1/10:1
Input dynamic range ± 1 V, 2 Vpp (@2:1)/± V, 10 Vpp (@10:1), mains isolated
Input common mode range ± 15 V (from DC to 100 Hz), ± 2.5 V (for >100 Hz)****
Offset range ± 15 V
Offset accuracy** < 3 %
Maximum non-destructive
input voltage
± 30 V (DC + peak AC), mains isolated
* Denotes warranted electrical specications at 2:1 attenuation mode after 20 minute warm-up, All others are typical.
** When calibrated on the oscilloscope, these characteristics are determined by the oscilloscope characteristics.
*** The N2750A Series differential probes can be used with the Inniium 90000X/Q Series scope and the N5442A precision BNC adapter.
**** Assumes symmetric differential signals.