Datasheet

This information is subject to change without notice.
© Keysight Technologies, 2013 - 2017
Published in USA, January 17, 2017
5992-0192EN
www.keysight.com
Keysight | InfiniiVision X-Series Oscilloscope Family - Selection Guide
Serial protocol trigger and decode 1000-X 2000-X 3000T-X 4000-X 6000-X
Aerospace and defense (MIL-STD
1553/ARINC 429)
X X X
Audio (I
2
S) X X X
Automotive X X X X
CAN X X X X X
LIN X X X X X
CAN-dbc X X X
CAN-FD X X X
CXPI X X
Computer (RS232/UART) X X X X X
Embedded (I
2
C, SPI) X X X X X
FlexRay X X X
Single edge nibble transmission
(SENT)
X X X
USB 2.0 X X
Low/Full speed X X
Hi-speed X X
Measurement applications
Enhanced video/TV application
package
X X X
FPGA dynamic probe option for
Xilinx
X X
Jitter and real time eye analysis X
Integrated 3-digit DVM/5 digit
counter
X X X X X
Integrated 8-digit precision counter X X
Integrated 10-digit precision
counter
X
Mask limit testing X X X X X
Power analysis application X X X
USB 2.0 signal quality analysis X X
Near field communication testing X X
WaveGen 20 MHz function
generator
X X X X X
AWG X X X
Dual channel X X
Productivity tools
Education and training kit X X X X X
N8900A Infiniium Offline oscil-
loscope analysis software
X X X X X
BenchVue X X X X X
Software application bundle X X X X
Standard and recommended
optional probes
1000-X 2000-X 3000T-X 4000-X 6000-X
Standard passive probe N2142A and
N2040A
Varies N2843A
(500 MHz)
N2894A
(700 MHz)
N2894A
(700 MHz)
8 digital channel MSO cable MSO models
16 digital channel MSO cable MSO models MSO models MSO models
Passive probe 35 MHz, 1:1, 1 MW Recommended Recommended Recommended Recommended Recommended
Passive probe 350 MHz, 10:1/1:1
switchable attenuation
Recommended Recommended Recommended Recommended Recommended
Passive probe 250 MHz 100:1
attenuation (4 kV)
Recommended Recommended Recommended Recommended Recommended
Active single-ended probe 1 GHz
1 pF 1 MΩ with AutoProbe
Recommended Recommended Recommended
Active single-ended probe 1.5 GHz
extreme temperature
Recommended Recommended Recommended
InfiniiMode differential probe
1.5 GHz 700 fF 200 kΩ with
AutoProbe
Recommended Recommended Recommended
Differential active probe 100 MHz,
± 1.4 kV with AutoProbe
Recommended Recommended Recommended
Differential active probe 250 MHz,
± 700 V
Recommended Recommended Recommended
200 MHz 10:1 Differential Probe
with AutoProbe
Recommended Recommended Recommended
800 MHz 10:1 Differential Probe
with AutoProbe
Recommended Recommended Recommended
AC/DC Current probe 100 kHz
100 A
Recommended Recommended Recommended
AC/DC Current probe 50 MHz 15 A
with AutoProbe
Recommended Recommended Recommended
AC/DC current probe 100 MHz
15 A with AutoProbe
Recommended Recommended Recommended
2-channel high-sensitivity current
probe 50 μA to 5 A
Recommended Recommended Recommended
1-channel high-sensitivity current
probe 50 μA to 5 A
Recommended Recommended Recommended
Low noise 2 GHz power rail probe Compatible Compatible Recommended
Accessories and connectivity
options
LAN/VGA connection module Option Option Standard Standard
GPIB connection module Option Option Option Option
Front panel cover Option Option Standard Standard
Rack mount kit Option Option Option Option Option
Soft carrying case Option Option Option Option Option
Hard copy manual Option Option Option Option Option