User Manual
Table Of Contents
- In This Book
- Contents
- What's New
- Setting Up
- Getting Started
- Basic Oscilloscope Program Structure
- Programming the Oscilloscope
- Referencing the IO Library
- Opening the Oscilloscope Connection via the IO Library
- Initializing the Interface and the Oscilloscope
- Using :AUToscale to Automate Oscilloscope Setup
- Using Other Oscilloscope Setup Commands
- Capturing Data with the :DIGitize Command
- Reading Query Responses from the Oscilloscope
- Reading Query Results into String Variables
- Reading Query Results into Numeric Variables
- Reading Definite-Length Block Query Response Data
- Sending Multiple Queries and Reading Results
- Checking Instrument Status
- Commands Quick Reference
- Common (*) Commands
- *CLS (Clear Status)
- *ESE (Standard Event Status Enable)
- *ESR (Standard Event Status Register)
- *IDN (Identification Number)
- *LRN (Learn Device Setup)
- *OPC (Operation Complete)
- *OPT (Option Identification)
- *RCL (Recall)
- *RST (Reset)
- *SAV (Save)
- *SRE (Service Request Enable)
- *STB (Read Status Byte)
- *TRG (Trigger)
- *TST (Self Test)
- *WAI (Wait To Continue)
- Root (:) Commands
- :AER (Arm Event Register)
- :AUToscale
- :AUToscale:AMODE
- :AUToscale:CHANnels
- :AUToscale:FDEBug
- :BLANk
- :DIGitize
- :MTEenable (Mask Test Event Enable Register)
- :MTERegister[:EVENt] (Mask Test Event Event Register)
- :OPEE (Operation Status Enable Register)
- :OPERegister:CONDition (Operation Status Condition Register)
- :OPERegister[:EVENt] (Operation Status Event Register)
- :OVLenable (Overload Event Enable Register)
- :OVLRegister (Overload Event Register)
- :RUN
- :SERial
- :SINGle
- :STATus
- :STOP
- :TER (Trigger Event Register)
- :VIEW
- :ABUS Commands
- :ACQuire Commands
- :CALibrate Commands
- :CHANnel
Commands - :CHANnel
:BANDwidth - :CHANnel
:BWLimit - :CHANnel
:COUPling - :CHANnel
:DISPlay - :CHANnel
:IMPedance - :CHANnel
:INVert - :CHANnel
:LABel - :CHANnel
:OFFSet - :CHANnel
:PROBe - :CHANnel
:PROBe:HEAD[:TYPE] - :CHANnel
:PROBe:ID - :CHANnel
:PROBe:SKEW - :CHANnel
:PROBe:STYPe - :CHANnel
:PROTection - :CHANnel
:RANGe - :CHANnel
:SCALe - :CHANnel
:UNITs - :CHANnel
:VERNier
- :CHANnel
- :DEMO Commands
- :DISPlay Commands
- :DVM Commands
- :EXTernal Trigger Commands
- :FFT Commands
- :FRANalysis Commands
- :FUNCtion Commands
- :FUNCtion:DISPlay
- :FUNCtion[:FFT]:CENTer
- :FUNCtion[:FFT]:PHASe:REFerence
- :FUNCtion[:FFT]:SPAN
- :FUNCtion[:FFT]:VTYPe
- :FUNCtion[:FFT]:WINDow
- :FUNCtion:FREQuency:LOWPass
- :FUNCtion:GOFT:OPERation
- :FUNCtion:GOFT:SOURce1
- :FUNCtion:GOFT:SOURce2
- :FUNCtion:OFFSet
- :FUNCtion:OPERation
- :FUNCtion:RANGe
- :FUNCtion:REFerence
- :FUNCtion:SCALe
- :FUNCtion:SOURce1
- :FUNCtion:SOURce2
- :HARDcopy Commands
- :MARKer Commands
- :MEASure Commands
- :MEASure:ALL
- :MEASure:BRATe
- :MEASure:CLEar
- :MEASure:COUNter
- :MEASure:DEFine
- :MEASure:DELay
- :MEASure:DUTYcycle
- :MEASure:FALLtime
- :MEASure:FREQuency
- :MEASure:NDUTy
- :MEASure:NWIDth
- :MEASure:OVERshoot
- :MEASure:PERiod
- :MEASure:PHASe
- :MEASure:PREShoot
- :MEASure:PWIDth
- :MEASure:RESults
- :MEASure:RISetime
- :MEASure:SDEViation
- :MEASure:SHOW
- :MEASure:SOURce
- :MEASure:TEDGe
- :MEASure:TVALue
- :MEASure:VAMPlitude
- :MEASure:VAVerage
- :MEASure:VBASe
- :MEASure:VMAX
- :MEASure:VMIN
- :MEASure:VPP
- :MEASure:VRMS
- :MEASure:VTIMe
- :MEASure:VTOP
- :MEASure:WINDow
- :MEASure:XMAX
- :MEASure:XMIN
- :MTESt Commands
- :MTESt:ALL
- :MTESt:AMASk:CREate
- :MTESt:AMASk:SOURce
- :MTESt:AMASk:UNITs
- :MTESt:AMASk:XDELta
- :MTESt:AMASk:YDELta
- :MTESt:COUNt:FWAVeforms
- :MTESt:COUNt:RESet
- :MTESt:COUNt:TIME
- :MTESt:COUNt:WAVeforms
- :MTESt:DATA
- :MTESt:DELete
- :MTESt:ENABle
- :MTESt:LOCK
- :MTESt:RMODe
- :MTESt:RMODe:FACTion:MEASure
- :MTESt:RMODe:FACTion:PRINt
- :MTESt:RMODe:FACTion:SAVE
- :MTESt:RMODe:FACTion:STOP
- :MTESt:RMODe:SIGMa
- :MTESt:RMODe:TIME
- :MTESt:RMODe:WAVeforms
- :MTESt:SCALe:BIND
- :MTESt:SCALe:X1
- :MTESt:SCALe:XDELta
- :MTESt:SCALe:Y1
- :MTESt:SCALe:Y2
- :MTESt:SOURce
- :MTESt:TITLe
- :RECall Commands
- :SAVE Commands
- :SAVE:FILename
- :SAVE:IMAGe[:STARt]
- :SAVE:IMAGe:FACTors
- :SAVE:IMAGe:FORMat
- :SAVE:IMAGe:INKSaver
- :SAVE:IMAGe:PALette
- :SAVE:MASK[:STARt]
- :SAVE:MULTi[:STARt]
- :SAVE:PWD
- :SAVE:SETup[:STARt]
- :SAVE:WAVeform[:STARt]
- :SAVE:WAVeform:FORMat
- :SAVE:WAVeform:LENGth
- :SAVE:WAVeform:LENGth:MAX
- :SAVE:WAVeform:SEGMented
- :SAVE:WMEMory:SOURce
- :SAVE:WMEMory[:STARt]
- :SBUS
Commands - General :SBUS
Commands - :SBUS
:CAN Commands - :SBUS
:CAN:COUNt:ERRor - :SBUS
:CAN:COUNt:OVERload - :SBUS
:CAN:COUNt:RESet - :SBUS
:CAN:COUNt:TOTal - :SBUS
:CAN:COUNt:UTILization - :SBUS
:CAN:SAMPlepoint - :SBUS
:CAN:SIGNal:BAUDrate - :SBUS
:CAN:SIGNal:DEFinition - :SBUS
:CAN:SOURce - :SBUS
:CAN:TRIGger - :SBUS
:CAN:TRIGger:PATTern:DATA - :SBUS
:CAN:TRIGger:PATTern:DATA:LENGth - :SBUS
:CAN:TRIGger:PATTern:ID - :SBUS
:CAN:TRIGger:PATTern:ID:MODE
- :SBUS
- :SBUS
:IIC Commands - :SBUS
:LIN Commands - :SBUS
:SPI Commands - :SBUS
:SPI:BITorder - :SBUS
:SPI:CLOCk:SLOPe - :SBUS
:SPI:CLOCk:TIMeout - :SBUS
:SPI:FRAMing - :SBUS
:SPI:SOURce:CLOCk - :SBUS
:SPI:SOURce:FRAMe - :SBUS
:SPI:SOURce:MISO - :SBUS
:SPI:SOURce:MOSI - :SBUS
:SPI:TRIGger:PATTern:MISO:DATA - :SBUS
:SPI:TRIGger:PATTern:MISO:WIDTh - :SBUS
:SPI:TRIGger:PATTern:MOSI:DATA - :SBUS
:SPI:TRIGger:PATTern:MOSI:WIDTh - :SBUS
:SPI:TRIGger:TYPE - :SBUS
:SPI:WIDTh
- :SBUS
- :SBUS
:UART Commands - :SBUS
:UART:BASE - :SBUS
:UART:BAUDrate - :SBUS
:UART:BITorder - :SBUS
:UART:COUNt:ERRor - :SBUS
:UART:COUNt:RESet - :SBUS
:UART:COUNt:RXFRames - :SBUS
:UART:COUNt:TXFRames - :SBUS
:UART:FRAMing - :SBUS
:UART:PARity - :SBUS
:UART:POLarity - :SBUS
:UART:SOURce:RX - :SBUS
:UART:SOURce:TX - :SBUS
:UART:TRIGger:BASE - :SBUS
:UART:TRIGger:BURSt - :SBUS
:UART:TRIGger:DATA - :SBUS
:UART:TRIGger:IDLE - :SBUS
:UART:TRIGger:QUALifier - :SBUS
:UART:TRIGger:TYPE - :SBUS
:UART:WIDTh
- :SBUS
- General :SBUS
- :SYSTem Commands
- :SYSTem:DATE
- :SYSTem:DSP
- :SYSTem:ERRor
- :SYSTem:LOCK
- :SYSTem:MENU
- :SYSTem:PERSona[:MANufacturer]
- :SYSTem:PERSona[:MANufacturer]:DEFault
- :SYSTem:PRESet
- :SYSTem:PROTection:LOCK
- :SYSTem:RLOGger
- :SYSTem:RLOGger:DESTination
- :SYSTem:RLOGger:DISPlay
- :SYSTem:RLOGger:FNAMe
- :SYSTem:RLOGger:STATe
- :SYSTem:RLOGger:TRANsparent
- :SYSTem:RLOGger:WMODe
- :SYSTem:SETup
- :SYSTem:TIME
- :TIMebase Commands
- :TRIGger Commands
- :WAVeform Commands
- :WAVeform:BYTeorder
- :WAVeform:COUNt
- :WAVeform:DATA
- :WAVeform:FORMat
- :WAVeform:POINts
- :WAVeform:POINts:MODE
- :WAVeform:PREamble
- :WAVeform:SEGMented:COUNt
- :WAVeform:SEGMented:TTAG
- :WAVeform:SOURce
- :WAVeform:SOURce:SUBSource
- :WAVeform:TYPE
- :WAVeform:UNSigned
- :WAVeform:VIEW
- :WAVeform:XINCrement
- :WAVeform:XORigin
- :WAVeform:XREFerence
- :WAVeform:YINCrement
- :WAVeform:YORigin
- :WAVeform:YREFerence
- :WGEN Commands
- :WGEN:FREQuency
- :WGEN:FUNCtion
- :WGEN:FUNCtion:PULSe:WIDTh
- :WGEN:FUNCtion:RAMP:SYMMetry
- :WGEN:FUNCtion:SQUare:DCYCle
- :WGEN:MODulation:AM:DEPTh
- :WGEN:MODulation:AM:FREQuency
- :WGEN:MODulation:FM:DEViation
- :WGEN:MODulation:FM:FREQuency
- :WGEN:MODulation:FSKey:FREQuency
- :WGEN:MODulation:FSKey:RATE
- :WGEN:MODulation:FUNCtion
- :WGEN:MODulation:FUNCtion:RAMP:SYMMetry
- :WGEN:MODulation:NOISe
- :WGEN:MODulation:STATe
- :WGEN:MODulation:TYPE
- :WGEN:OUTPut
- :WGEN:OUTPut:LOAD
- :WGEN:OUTPut:POLarity
- :WGEN:PERiod
- :WGEN:RST
- :WGEN:VOLTage
- :WGEN:VOLTage:HIGH
- :WGEN:VOLTage:LOW
- :WGEN:VOLTage:OFFSet
- :WMEMory
Commands - Obsolete and Discontinued Commands
- :CHANnel:LABel
- :CHANnel2:SKEW
- :CHANnel
:INPut - :CHANnel
:PMODe - :DISPlay:CONNect
- :ERASe
- :EXTernal:PMODe
- :FUNCtion:SOURce
- :FUNCtion:VIEW
- :HARDcopy:DESTination
- :HARDcopy:FILename
- :HARDcopy:GRAYscale
- :HARDcopy:IGColors
- :HARDcopy:PDRiver
- :MEASure:LOWer
- :MEASure:SCRatch
- :MEASure:TDELta
- :MEASure:THResholds
- :MEASure:TMAX
- :MEASure:TMIN
- :MEASure:TSTArt
- :MEASure:TSTOp
- :MEASure:TVOLt
- :MEASure:UPPer
- :MEASure:VDELta
- :MEASure:VSTArt
- :MEASure:VSTOp
- :MTESt:AMASk:{SAVE | STORe}
- :MTESt:AVERage
- :MTESt:AVERage:COUNt
- :MTESt:LOAD
- :MTESt:RUMode
- :MTESt:RUMode:SOFailure
- :MTESt:{STARt | STOP}
- :MTESt:TRIGger:SOURce
- :PRINt?
- :SAVE:IMAGe:AREA
- :TIMebase:DELay
- :TRIGger:TV:TVMode
- Error Messages
- Status Reporting
- Status Reporting Data Structures
- Status Byte Register (STB)
- Service Request Enable Register (SRE)
- Trigger Event Register (TER)
- Output Queue
- Message Queue
- (Standard) Event Status Register (ESR)
- (Standard) Event Status Enable Register (ESE)
- Error Queue
- Operation Status Event Register (:OPERegister[:EVENt])
- Operation Status Condition Register (:OPERegister:CONDition)
- Arm Event Register (AER)
- Overload Event Register (:OVLRegister)
- Mask Test Event Event Register (:MTERegister[:EVENt])
- Clearing Registers and Queues
- Status Reporting Decision Chart
- Synchronizing Acquisitions
- More About Oscilloscope Commands
- Programming Examples
- Index

724 Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide
31 Obsolete and Discontinued Commands
:MEASure:TVOLt
(see page 782)
Query Syntax
:MEASure:TVOLt? <value>, [<slope>]<occurrence>[,<source>]
<value> ::= the voltage level that the waveform must cross.
<slope> ::= direction of the waveform. A rising slope is indicated by
a plus sign (+). A falling edge is indicated by a minus
sign (-).
<occurrence> ::= the transition to be reported. If the occurrence
number is one, the first crossing is reported. If
the number is two, the second crossing is reported,
etc.
<source> ::= {CHANnel<n> | FUNCtion | MATH}
<n> ::= 1 to (# analog channels) in NR1 format
When the :MEASure:TVOLt? query is sent, the displayed signal is searched for the
specified voltage level and transition. The time interval between the trigger event
and this defined occurrence is returned as the response to the query.
The specified voltage can be negative or positive. To specify a negative voltage,
use a minus sign (-). The sign of the slope selects a rising (+) or falling (-) edge. If
no sign is specified for the slope, it is assumed to be the rising edge.
The magnitude of the occurrence defines the occurrence to be reported. For
example, +3 returns the time for the third time the waveform crosses the specified
voltage level in the positive direction. Once this voltage crossing is found, the
oscilloscope reports the time at that crossing in seconds, with the trigger point
(time zero) as the reference.
If the specified crossing cannot be found, the oscilloscope reports +9.9E+37. This
value is returned if the waveform does not cross the specified voltage, or if the
waveform does not cross the specified voltage for the specified number of times in
the direction specified.
If the optional source parameter is specified, the current source is modified.
Return Format
<value><NL>
<value> ::= time in seconds of the specified voltage crossing
in NR3 format
NOTE
The :MEASure:TVOLt command is obsolete and is provided for backward compatibility to
previous oscilloscopes. Use the :MEASure:TVALue command (see page 375).










