User Manual
Table Of Contents
- In This Book
- Contents
- What's New
- Setting Up
- Getting Started
- Basic Oscilloscope Program Structure
- Programming the Oscilloscope
- Referencing the IO Library
- Opening the Oscilloscope Connection via the IO Library
- Initializing the Interface and the Oscilloscope
- Using :AUToscale to Automate Oscilloscope Setup
- Using Other Oscilloscope Setup Commands
- Capturing Data with the :DIGitize Command
- Reading Query Responses from the Oscilloscope
- Reading Query Results into String Variables
- Reading Query Results into Numeric Variables
- Reading Definite-Length Block Query Response Data
- Sending Multiple Queries and Reading Results
- Checking Instrument Status
- Commands Quick Reference
- Common (*) Commands
- *CLS (Clear Status)
- *ESE (Standard Event Status Enable)
- *ESR (Standard Event Status Register)
- *IDN (Identification Number)
- *LRN (Learn Device Setup)
- *OPC (Operation Complete)
- *OPT (Option Identification)
- *RCL (Recall)
- *RST (Reset)
- *SAV (Save)
- *SRE (Service Request Enable)
- *STB (Read Status Byte)
- *TRG (Trigger)
- *TST (Self Test)
- *WAI (Wait To Continue)
- Root (:) Commands
- :AER (Arm Event Register)
- :AUToscale
- :AUToscale:AMODE
- :AUToscale:CHANnels
- :AUToscale:FDEBug
- :BLANk
- :DIGitize
- :MTEenable (Mask Test Event Enable Register)
- :MTERegister[:EVENt] (Mask Test Event Event Register)
- :OPEE (Operation Status Enable Register)
- :OPERegister:CONDition (Operation Status Condition Register)
- :OPERegister[:EVENt] (Operation Status Event Register)
- :OVLenable (Overload Event Enable Register)
- :OVLRegister (Overload Event Register)
- :RUN
- :SERial
- :SINGle
- :STATus
- :STOP
- :TER (Trigger Event Register)
- :VIEW
- :ABUS Commands
- :ACQuire Commands
- :CALibrate Commands
- :CHANnel
Commands - :CHANnel
:BANDwidth - :CHANnel
:BWLimit - :CHANnel
:COUPling - :CHANnel
:DISPlay - :CHANnel
:IMPedance - :CHANnel
:INVert - :CHANnel
:LABel - :CHANnel
:OFFSet - :CHANnel
:PROBe - :CHANnel
:PROBe:HEAD[:TYPE] - :CHANnel
:PROBe:ID - :CHANnel
:PROBe:SKEW - :CHANnel
:PROBe:STYPe - :CHANnel
:PROTection - :CHANnel
:RANGe - :CHANnel
:SCALe - :CHANnel
:UNITs - :CHANnel
:VERNier
- :CHANnel
- :DEMO Commands
- :DISPlay Commands
- :DVM Commands
- :EXTernal Trigger Commands
- :FFT Commands
- :FRANalysis Commands
- :FUNCtion Commands
- :FUNCtion:DISPlay
- :FUNCtion[:FFT]:CENTer
- :FUNCtion[:FFT]:PHASe:REFerence
- :FUNCtion[:FFT]:SPAN
- :FUNCtion[:FFT]:VTYPe
- :FUNCtion[:FFT]:WINDow
- :FUNCtion:FREQuency:LOWPass
- :FUNCtion:GOFT:OPERation
- :FUNCtion:GOFT:SOURce1
- :FUNCtion:GOFT:SOURce2
- :FUNCtion:OFFSet
- :FUNCtion:OPERation
- :FUNCtion:RANGe
- :FUNCtion:REFerence
- :FUNCtion:SCALe
- :FUNCtion:SOURce1
- :FUNCtion:SOURce2
- :HARDcopy Commands
- :MARKer Commands
- :MEASure Commands
- :MEASure:ALL
- :MEASure:BRATe
- :MEASure:CLEar
- :MEASure:COUNter
- :MEASure:DEFine
- :MEASure:DELay
- :MEASure:DUTYcycle
- :MEASure:FALLtime
- :MEASure:FREQuency
- :MEASure:NDUTy
- :MEASure:NWIDth
- :MEASure:OVERshoot
- :MEASure:PERiod
- :MEASure:PHASe
- :MEASure:PREShoot
- :MEASure:PWIDth
- :MEASure:RESults
- :MEASure:RISetime
- :MEASure:SDEViation
- :MEASure:SHOW
- :MEASure:SOURce
- :MEASure:TEDGe
- :MEASure:TVALue
- :MEASure:VAMPlitude
- :MEASure:VAVerage
- :MEASure:VBASe
- :MEASure:VMAX
- :MEASure:VMIN
- :MEASure:VPP
- :MEASure:VRMS
- :MEASure:VTIMe
- :MEASure:VTOP
- :MEASure:WINDow
- :MEASure:XMAX
- :MEASure:XMIN
- :MTESt Commands
- :MTESt:ALL
- :MTESt:AMASk:CREate
- :MTESt:AMASk:SOURce
- :MTESt:AMASk:UNITs
- :MTESt:AMASk:XDELta
- :MTESt:AMASk:YDELta
- :MTESt:COUNt:FWAVeforms
- :MTESt:COUNt:RESet
- :MTESt:COUNt:TIME
- :MTESt:COUNt:WAVeforms
- :MTESt:DATA
- :MTESt:DELete
- :MTESt:ENABle
- :MTESt:LOCK
- :MTESt:RMODe
- :MTESt:RMODe:FACTion:MEASure
- :MTESt:RMODe:FACTion:PRINt
- :MTESt:RMODe:FACTion:SAVE
- :MTESt:RMODe:FACTion:STOP
- :MTESt:RMODe:SIGMa
- :MTESt:RMODe:TIME
- :MTESt:RMODe:WAVeforms
- :MTESt:SCALe:BIND
- :MTESt:SCALe:X1
- :MTESt:SCALe:XDELta
- :MTESt:SCALe:Y1
- :MTESt:SCALe:Y2
- :MTESt:SOURce
- :MTESt:TITLe
- :RECall Commands
- :SAVE Commands
- :SAVE:FILename
- :SAVE:IMAGe[:STARt]
- :SAVE:IMAGe:FACTors
- :SAVE:IMAGe:FORMat
- :SAVE:IMAGe:INKSaver
- :SAVE:IMAGe:PALette
- :SAVE:MASK[:STARt]
- :SAVE:MULTi[:STARt]
- :SAVE:PWD
- :SAVE:SETup[:STARt]
- :SAVE:WAVeform[:STARt]
- :SAVE:WAVeform:FORMat
- :SAVE:WAVeform:LENGth
- :SAVE:WAVeform:LENGth:MAX
- :SAVE:WAVeform:SEGMented
- :SAVE:WMEMory:SOURce
- :SAVE:WMEMory[:STARt]
- :SBUS
Commands - General :SBUS
Commands - :SBUS
:CAN Commands - :SBUS
:CAN:COUNt:ERRor - :SBUS
:CAN:COUNt:OVERload - :SBUS
:CAN:COUNt:RESet - :SBUS
:CAN:COUNt:TOTal - :SBUS
:CAN:COUNt:UTILization - :SBUS
:CAN:SAMPlepoint - :SBUS
:CAN:SIGNal:BAUDrate - :SBUS
:CAN:SIGNal:DEFinition - :SBUS
:CAN:SOURce - :SBUS
:CAN:TRIGger - :SBUS
:CAN:TRIGger:PATTern:DATA - :SBUS
:CAN:TRIGger:PATTern:DATA:LENGth - :SBUS
:CAN:TRIGger:PATTern:ID - :SBUS
:CAN:TRIGger:PATTern:ID:MODE
- :SBUS
- :SBUS
:IIC Commands - :SBUS
:LIN Commands - :SBUS
:SPI Commands - :SBUS
:SPI:BITorder - :SBUS
:SPI:CLOCk:SLOPe - :SBUS
:SPI:CLOCk:TIMeout - :SBUS
:SPI:FRAMing - :SBUS
:SPI:SOURce:CLOCk - :SBUS
:SPI:SOURce:FRAMe - :SBUS
:SPI:SOURce:MISO - :SBUS
:SPI:SOURce:MOSI - :SBUS
:SPI:TRIGger:PATTern:MISO:DATA - :SBUS
:SPI:TRIGger:PATTern:MISO:WIDTh - :SBUS
:SPI:TRIGger:PATTern:MOSI:DATA - :SBUS
:SPI:TRIGger:PATTern:MOSI:WIDTh - :SBUS
:SPI:TRIGger:TYPE - :SBUS
:SPI:WIDTh
- :SBUS
- :SBUS
:UART Commands - :SBUS
:UART:BASE - :SBUS
:UART:BAUDrate - :SBUS
:UART:BITorder - :SBUS
:UART:COUNt:ERRor - :SBUS
:UART:COUNt:RESet - :SBUS
:UART:COUNt:RXFRames - :SBUS
:UART:COUNt:TXFRames - :SBUS
:UART:FRAMing - :SBUS
:UART:PARity - :SBUS
:UART:POLarity - :SBUS
:UART:SOURce:RX - :SBUS
:UART:SOURce:TX - :SBUS
:UART:TRIGger:BASE - :SBUS
:UART:TRIGger:BURSt - :SBUS
:UART:TRIGger:DATA - :SBUS
:UART:TRIGger:IDLE - :SBUS
:UART:TRIGger:QUALifier - :SBUS
:UART:TRIGger:TYPE - :SBUS
:UART:WIDTh
- :SBUS
- General :SBUS
- :SYSTem Commands
- :SYSTem:DATE
- :SYSTem:DSP
- :SYSTem:ERRor
- :SYSTem:LOCK
- :SYSTem:MENU
- :SYSTem:PERSona[:MANufacturer]
- :SYSTem:PERSona[:MANufacturer]:DEFault
- :SYSTem:PRESet
- :SYSTem:PROTection:LOCK
- :SYSTem:RLOGger
- :SYSTem:RLOGger:DESTination
- :SYSTem:RLOGger:DISPlay
- :SYSTem:RLOGger:FNAMe
- :SYSTem:RLOGger:STATe
- :SYSTem:RLOGger:TRANsparent
- :SYSTem:RLOGger:WMODe
- :SYSTem:SETup
- :SYSTem:TIME
- :TIMebase Commands
- :TRIGger Commands
- :WAVeform Commands
- :WAVeform:BYTeorder
- :WAVeform:COUNt
- :WAVeform:DATA
- :WAVeform:FORMat
- :WAVeform:POINts
- :WAVeform:POINts:MODE
- :WAVeform:PREamble
- :WAVeform:SEGMented:COUNt
- :WAVeform:SEGMented:TTAG
- :WAVeform:SOURce
- :WAVeform:SOURce:SUBSource
- :WAVeform:TYPE
- :WAVeform:UNSigned
- :WAVeform:VIEW
- :WAVeform:XINCrement
- :WAVeform:XORigin
- :WAVeform:XREFerence
- :WAVeform:YINCrement
- :WAVeform:YORigin
- :WAVeform:YREFerence
- :WGEN Commands
- :WGEN:FREQuency
- :WGEN:FUNCtion
- :WGEN:FUNCtion:PULSe:WIDTh
- :WGEN:FUNCtion:RAMP:SYMMetry
- :WGEN:FUNCtion:SQUare:DCYCle
- :WGEN:MODulation:AM:DEPTh
- :WGEN:MODulation:AM:FREQuency
- :WGEN:MODulation:FM:DEViation
- :WGEN:MODulation:FM:FREQuency
- :WGEN:MODulation:FSKey:FREQuency
- :WGEN:MODulation:FSKey:RATE
- :WGEN:MODulation:FUNCtion
- :WGEN:MODulation:FUNCtion:RAMP:SYMMetry
- :WGEN:MODulation:NOISe
- :WGEN:MODulation:STATe
- :WGEN:MODulation:TYPE
- :WGEN:OUTPut
- :WGEN:OUTPut:LOAD
- :WGEN:OUTPut:POLarity
- :WGEN:PERiod
- :WGEN:RST
- :WGEN:VOLTage
- :WGEN:VOLTage:HIGH
- :WGEN:VOLTage:LOW
- :WGEN:VOLTage:OFFSet
- :WMEMory
Commands - Obsolete and Discontinued Commands
- :CHANnel:LABel
- :CHANnel2:SKEW
- :CHANnel
:INPut - :CHANnel
:PMODe - :DISPlay:CONNect
- :ERASe
- :EXTernal:PMODe
- :FUNCtion:SOURce
- :FUNCtion:VIEW
- :HARDcopy:DESTination
- :HARDcopy:FILename
- :HARDcopy:GRAYscale
- :HARDcopy:IGColors
- :HARDcopy:PDRiver
- :MEASure:LOWer
- :MEASure:SCRatch
- :MEASure:TDELta
- :MEASure:THResholds
- :MEASure:TMAX
- :MEASure:TMIN
- :MEASure:TSTArt
- :MEASure:TSTOp
- :MEASure:TVOLt
- :MEASure:UPPer
- :MEASure:VDELta
- :MEASure:VSTArt
- :MEASure:VSTOp
- :MTESt:AMASk:{SAVE | STORe}
- :MTESt:AVERage
- :MTESt:AVERage:COUNt
- :MTESt:LOAD
- :MTESt:RUMode
- :MTESt:RUMode:SOFailure
- :MTESt:{STARt | STOP}
- :MTESt:TRIGger:SOURce
- :PRINt?
- :SAVE:IMAGe:AREA
- :TIMebase:DELay
- :TRIGger:TV:TVMode
- Error Messages
- Status Reporting
- Status Reporting Data Structures
- Status Byte Register (STB)
- Service Request Enable Register (SRE)
- Trigger Event Register (TER)
- Output Queue
- Message Queue
- (Standard) Event Status Register (ESR)
- (Standard) Event Status Enable Register (ESE)
- Error Queue
- Operation Status Event Register (:OPERegister[:EVENt])
- Operation Status Condition Register (:OPERegister:CONDition)
- Arm Event Register (AER)
- Overload Event Register (:OVLRegister)
- Mask Test Event Event Register (:MTERegister[:EVENt])
- Clearing Registers and Queues
- Status Reporting Decision Chart
- Synchronizing Acquisitions
- More About Oscilloscope Commands
- Programming Examples
- Index
624 Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide
28 :WAVeform Commands
If the :WAVeform:FORMat data format is ASCii (see page 630), the data values are
converted internally and sent as floating point values separated by commas.
In converting a data value to time, the time value of a data point can be
determined by the position of the data point. For example, the fourth data point
sent with :WAVeform:XORigin = 16 ns, :WAVeform:XREFerence = 0, and
:WAVeform:XINCrement = 2 ns, can be calculated using the following formula:
time = [(data point number - xreference) * xincrement] + xorigin
This would result in the following calculation for time bucket 3:
time = [(3 - 0) * 2 ns] + 16 ns = 22 ns
In :ACQuire:TYPE PEAK mode (see page 187), because data is acquired in
max-min pairs, modify the previous time formula to the following:
time=[(data pair number - xreference) * xincrement * 2] + xorigin
Data Format for Transfer
There are three formats for transferring waveform data over the interface: BYTE,
WORD and ASCii (see ":WAVeform:FORMat" on page 630). BYTE, WORD and
ASCii formatted waveform records are transmitted using the arbitrary block
program data format specified in IEEE 488.2.
When you use the block data format, the ASCII character string "#8<DD...D>" is
sent prior to sending the actual data. The 8 indicates how many Ds follow. The Ds
are ASCII numbers that indicate how many data bytes follow.
For example, if 1000 points will be transferred, and the WORD format was
specified, the block header "#800001000" would be sent. The 8 indicates that
eight length bytes follow, and 00001000 indicates that 1000 binary data bytes
follow.
Use the :WAVeform:UNSigned command (see page 646) to control whether data
values are sent as unsigned or signed integers. This command can be used to
match the instrument's internal data type to the data type used by the
programming language. This command has no effect if the data format is ASCii.
Data Format for Transfer - ASCii format
The ASCii format (see ":WAVeform:FORMat" on page 630) provides access to
the waveform data as real Y-axis values without using Y origin, Y reference, and
Y increment to convert the binary data. Values are transferred as ASCii digits in
floating point format separated by commas. In ASCii format, holes are
represented by the value 9.9e+37. The setting of :WAVeform:BYTeorder (see
page 626) and :WAVeform:UNSigned (see page 646) have no effect when the
format is ASCii.
Data Format for Transfer - WORD format