User Manual

Table Of Contents
:SBUS<n> Commands 24
Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide 525
:SBUS<n>:UART:SOURce:RX
(see page 782)
Command Syntax
:SBUS<n>:UART:SOURce:RX <source>
<source> ::= {CHANnel<n> | EXTernal}
<n> ::= 1 to (# analog channels) in NR1 format
The :SBUS<n>:UART:SOURce:RX command controls which signal is used as the
Rx source by the serial decoder and/or trigger when in UART mode.
Query Syntax
:SBUS<n>:UART:SOURce:RX?
The :SBUS<n>:UART:SOURce:RX? query returns the current source for the UART
Rx signal.
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 571
":TRIGger:MODE" on page 580
":SBUS<n>:UART:TRIGger:TYPE" on page 532
":SBUS<n>:UART:BITorder" on page 517