User Manual
Table Of Contents
- In This Book
- Contents
- What's New
- Setting Up
- Getting Started
- Basic Oscilloscope Program Structure
- Programming the Oscilloscope
- Referencing the IO Library
- Opening the Oscilloscope Connection via the IO Library
- Initializing the Interface and the Oscilloscope
- Using :AUToscale to Automate Oscilloscope Setup
- Using Other Oscilloscope Setup Commands
- Capturing Data with the :DIGitize Command
- Reading Query Responses from the Oscilloscope
- Reading Query Results into String Variables
- Reading Query Results into Numeric Variables
- Reading Definite-Length Block Query Response Data
- Sending Multiple Queries and Reading Results
- Checking Instrument Status
- Commands Quick Reference
- Common (*) Commands
- *CLS (Clear Status)
- *ESE (Standard Event Status Enable)
- *ESR (Standard Event Status Register)
- *IDN (Identification Number)
- *LRN (Learn Device Setup)
- *OPC (Operation Complete)
- *OPT (Option Identification)
- *RCL (Recall)
- *RST (Reset)
- *SAV (Save)
- *SRE (Service Request Enable)
- *STB (Read Status Byte)
- *TRG (Trigger)
- *TST (Self Test)
- *WAI (Wait To Continue)
- Root (:) Commands
- :AER (Arm Event Register)
- :AUToscale
- :AUToscale:AMODE
- :AUToscale:CHANnels
- :AUToscale:FDEBug
- :BLANk
- :DIGitize
- :MTEenable (Mask Test Event Enable Register)
- :MTERegister[:EVENt] (Mask Test Event Event Register)
- :OPEE (Operation Status Enable Register)
- :OPERegister:CONDition (Operation Status Condition Register)
- :OPERegister[:EVENt] (Operation Status Event Register)
- :OVLenable (Overload Event Enable Register)
- :OVLRegister (Overload Event Register)
- :RUN
- :SERial
- :SINGle
- :STATus
- :STOP
- :TER (Trigger Event Register)
- :VIEW
- :ABUS Commands
- :ACQuire Commands
- :CALibrate Commands
- :CHANnel
Commands - :CHANnel
:BANDwidth - :CHANnel
:BWLimit - :CHANnel
:COUPling - :CHANnel
:DISPlay - :CHANnel
:IMPedance - :CHANnel
:INVert - :CHANnel
:LABel - :CHANnel
:OFFSet - :CHANnel
:PROBe - :CHANnel
:PROBe:HEAD[:TYPE] - :CHANnel
:PROBe:ID - :CHANnel
:PROBe:SKEW - :CHANnel
:PROBe:STYPe - :CHANnel
:PROTection - :CHANnel
:RANGe - :CHANnel
:SCALe - :CHANnel
:UNITs - :CHANnel
:VERNier
- :CHANnel
- :DEMO Commands
- :DISPlay Commands
- :DVM Commands
- :EXTernal Trigger Commands
- :FFT Commands
- :FRANalysis Commands
- :FUNCtion Commands
- :FUNCtion:DISPlay
- :FUNCtion[:FFT]:CENTer
- :FUNCtion[:FFT]:PHASe:REFerence
- :FUNCtion[:FFT]:SPAN
- :FUNCtion[:FFT]:VTYPe
- :FUNCtion[:FFT]:WINDow
- :FUNCtion:FREQuency:LOWPass
- :FUNCtion:GOFT:OPERation
- :FUNCtion:GOFT:SOURce1
- :FUNCtion:GOFT:SOURce2
- :FUNCtion:OFFSet
- :FUNCtion:OPERation
- :FUNCtion:RANGe
- :FUNCtion:REFerence
- :FUNCtion:SCALe
- :FUNCtion:SOURce1
- :FUNCtion:SOURce2
- :HARDcopy Commands
- :MARKer Commands
- :MEASure Commands
- :MEASure:ALL
- :MEASure:BRATe
- :MEASure:CLEar
- :MEASure:COUNter
- :MEASure:DEFine
- :MEASure:DELay
- :MEASure:DUTYcycle
- :MEASure:FALLtime
- :MEASure:FREQuency
- :MEASure:NDUTy
- :MEASure:NWIDth
- :MEASure:OVERshoot
- :MEASure:PERiod
- :MEASure:PHASe
- :MEASure:PREShoot
- :MEASure:PWIDth
- :MEASure:RESults
- :MEASure:RISetime
- :MEASure:SDEViation
- :MEASure:SHOW
- :MEASure:SOURce
- :MEASure:TEDGe
- :MEASure:TVALue
- :MEASure:VAMPlitude
- :MEASure:VAVerage
- :MEASure:VBASe
- :MEASure:VMAX
- :MEASure:VMIN
- :MEASure:VPP
- :MEASure:VRMS
- :MEASure:VTIMe
- :MEASure:VTOP
- :MEASure:WINDow
- :MEASure:XMAX
- :MEASure:XMIN
- :MTESt Commands
- :MTESt:ALL
- :MTESt:AMASk:CREate
- :MTESt:AMASk:SOURce
- :MTESt:AMASk:UNITs
- :MTESt:AMASk:XDELta
- :MTESt:AMASk:YDELta
- :MTESt:COUNt:FWAVeforms
- :MTESt:COUNt:RESet
- :MTESt:COUNt:TIME
- :MTESt:COUNt:WAVeforms
- :MTESt:DATA
- :MTESt:DELete
- :MTESt:ENABle
- :MTESt:LOCK
- :MTESt:RMODe
- :MTESt:RMODe:FACTion:MEASure
- :MTESt:RMODe:FACTion:PRINt
- :MTESt:RMODe:FACTion:SAVE
- :MTESt:RMODe:FACTion:STOP
- :MTESt:RMODe:SIGMa
- :MTESt:RMODe:TIME
- :MTESt:RMODe:WAVeforms
- :MTESt:SCALe:BIND
- :MTESt:SCALe:X1
- :MTESt:SCALe:XDELta
- :MTESt:SCALe:Y1
- :MTESt:SCALe:Y2
- :MTESt:SOURce
- :MTESt:TITLe
- :RECall Commands
- :SAVE Commands
- :SAVE:FILename
- :SAVE:IMAGe[:STARt]
- :SAVE:IMAGe:FACTors
- :SAVE:IMAGe:FORMat
- :SAVE:IMAGe:INKSaver
- :SAVE:IMAGe:PALette
- :SAVE:MASK[:STARt]
- :SAVE:MULTi[:STARt]
- :SAVE:PWD
- :SAVE:SETup[:STARt]
- :SAVE:WAVeform[:STARt]
- :SAVE:WAVeform:FORMat
- :SAVE:WAVeform:LENGth
- :SAVE:WAVeform:LENGth:MAX
- :SAVE:WAVeform:SEGMented
- :SAVE:WMEMory:SOURce
- :SAVE:WMEMory[:STARt]
- :SBUS
Commands - General :SBUS
Commands - :SBUS
:CAN Commands - :SBUS
:CAN:COUNt:ERRor - :SBUS
:CAN:COUNt:OVERload - :SBUS
:CAN:COUNt:RESet - :SBUS
:CAN:COUNt:TOTal - :SBUS
:CAN:COUNt:UTILization - :SBUS
:CAN:SAMPlepoint - :SBUS
:CAN:SIGNal:BAUDrate - :SBUS
:CAN:SIGNal:DEFinition - :SBUS
:CAN:SOURce - :SBUS
:CAN:TRIGger - :SBUS
:CAN:TRIGger:PATTern:DATA - :SBUS
:CAN:TRIGger:PATTern:DATA:LENGth - :SBUS
:CAN:TRIGger:PATTern:ID - :SBUS
:CAN:TRIGger:PATTern:ID:MODE
- :SBUS
- :SBUS
:IIC Commands - :SBUS
:LIN Commands - :SBUS
:SPI Commands - :SBUS
:SPI:BITorder - :SBUS
:SPI:CLOCk:SLOPe - :SBUS
:SPI:CLOCk:TIMeout - :SBUS
:SPI:FRAMing - :SBUS
:SPI:SOURce:CLOCk - :SBUS
:SPI:SOURce:FRAMe - :SBUS
:SPI:SOURce:MISO - :SBUS
:SPI:SOURce:MOSI - :SBUS
:SPI:TRIGger:PATTern:MISO:DATA - :SBUS
:SPI:TRIGger:PATTern:MISO:WIDTh - :SBUS
:SPI:TRIGger:PATTern:MOSI:DATA - :SBUS
:SPI:TRIGger:PATTern:MOSI:WIDTh - :SBUS
:SPI:TRIGger:TYPE - :SBUS
:SPI:WIDTh
- :SBUS
- :SBUS
:UART Commands - :SBUS
:UART:BASE - :SBUS
:UART:BAUDrate - :SBUS
:UART:BITorder - :SBUS
:UART:COUNt:ERRor - :SBUS
:UART:COUNt:RESet - :SBUS
:UART:COUNt:RXFRames - :SBUS
:UART:COUNt:TXFRames - :SBUS
:UART:FRAMing - :SBUS
:UART:PARity - :SBUS
:UART:POLarity - :SBUS
:UART:SOURce:RX - :SBUS
:UART:SOURce:TX - :SBUS
:UART:TRIGger:BASE - :SBUS
:UART:TRIGger:BURSt - :SBUS
:UART:TRIGger:DATA - :SBUS
:UART:TRIGger:IDLE - :SBUS
:UART:TRIGger:QUALifier - :SBUS
:UART:TRIGger:TYPE - :SBUS
:UART:WIDTh
- :SBUS
- General :SBUS
- :SYSTem Commands
- :SYSTem:DATE
- :SYSTem:DSP
- :SYSTem:ERRor
- :SYSTem:LOCK
- :SYSTem:MENU
- :SYSTem:PERSona[:MANufacturer]
- :SYSTem:PERSona[:MANufacturer]:DEFault
- :SYSTem:PRESet
- :SYSTem:PROTection:LOCK
- :SYSTem:RLOGger
- :SYSTem:RLOGger:DESTination
- :SYSTem:RLOGger:DISPlay
- :SYSTem:RLOGger:FNAMe
- :SYSTem:RLOGger:STATe
- :SYSTem:RLOGger:TRANsparent
- :SYSTem:RLOGger:WMODe
- :SYSTem:SETup
- :SYSTem:TIME
- :TIMebase Commands
- :TRIGger Commands
- :WAVeform Commands
- :WAVeform:BYTeorder
- :WAVeform:COUNt
- :WAVeform:DATA
- :WAVeform:FORMat
- :WAVeform:POINts
- :WAVeform:POINts:MODE
- :WAVeform:PREamble
- :WAVeform:SEGMented:COUNt
- :WAVeform:SEGMented:TTAG
- :WAVeform:SOURce
- :WAVeform:SOURce:SUBSource
- :WAVeform:TYPE
- :WAVeform:UNSigned
- :WAVeform:VIEW
- :WAVeform:XINCrement
- :WAVeform:XORigin
- :WAVeform:XREFerence
- :WAVeform:YINCrement
- :WAVeform:YORigin
- :WAVeform:YREFerence
- :WGEN Commands
- :WGEN:FREQuency
- :WGEN:FUNCtion
- :WGEN:FUNCtion:PULSe:WIDTh
- :WGEN:FUNCtion:RAMP:SYMMetry
- :WGEN:FUNCtion:SQUare:DCYCle
- :WGEN:MODulation:AM:DEPTh
- :WGEN:MODulation:AM:FREQuency
- :WGEN:MODulation:FM:DEViation
- :WGEN:MODulation:FM:FREQuency
- :WGEN:MODulation:FSKey:FREQuency
- :WGEN:MODulation:FSKey:RATE
- :WGEN:MODulation:FUNCtion
- :WGEN:MODulation:FUNCtion:RAMP:SYMMetry
- :WGEN:MODulation:NOISe
- :WGEN:MODulation:STATe
- :WGEN:MODulation:TYPE
- :WGEN:OUTPut
- :WGEN:OUTPut:LOAD
- :WGEN:OUTPut:POLarity
- :WGEN:PERiod
- :WGEN:RST
- :WGEN:VOLTage
- :WGEN:VOLTage:HIGH
- :WGEN:VOLTage:LOW
- :WGEN:VOLTage:OFFSet
- :WMEMory
Commands - Obsolete and Discontinued Commands
- :CHANnel:LABel
- :CHANnel2:SKEW
- :CHANnel
:INPut - :CHANnel
:PMODe - :DISPlay:CONNect
- :ERASe
- :EXTernal:PMODe
- :FUNCtion:SOURce
- :FUNCtion:VIEW
- :HARDcopy:DESTination
- :HARDcopy:FILename
- :HARDcopy:GRAYscale
- :HARDcopy:IGColors
- :HARDcopy:PDRiver
- :MEASure:LOWer
- :MEASure:SCRatch
- :MEASure:TDELta
- :MEASure:THResholds
- :MEASure:TMAX
- :MEASure:TMIN
- :MEASure:TSTArt
- :MEASure:TSTOp
- :MEASure:TVOLt
- :MEASure:UPPer
- :MEASure:VDELta
- :MEASure:VSTArt
- :MEASure:VSTOp
- :MTESt:AMASk:{SAVE | STORe}
- :MTESt:AVERage
- :MTESt:AVERage:COUNt
- :MTESt:LOAD
- :MTESt:RUMode
- :MTESt:RUMode:SOFailure
- :MTESt:{STARt | STOP}
- :MTESt:TRIGger:SOURce
- :PRINt?
- :SAVE:IMAGe:AREA
- :TIMebase:DELay
- :TRIGger:TV:TVMode
- Error Messages
- Status Reporting
- Status Reporting Data Structures
- Status Byte Register (STB)
- Service Request Enable Register (SRE)
- Trigger Event Register (TER)
- Output Queue
- Message Queue
- (Standard) Event Status Register (ESR)
- (Standard) Event Status Enable Register (ESE)
- Error Queue
- Operation Status Event Register (:OPERegister[:EVENt])
- Operation Status Condition Register (:OPERegister:CONDition)
- Arm Event Register (AER)
- Overload Event Register (:OVLRegister)
- Mask Test Event Event Register (:MTERegister[:EVENt])
- Clearing Registers and Queues
- Status Reporting Decision Chart
- Synchronizing Acquisitions
- More About Oscilloscope Commands
- Programming Examples
- Index

354 Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide
20 :MEASure Commands
:MEASure:DELay
(see page 782)
Command Syntax
:MEASure:DELay [<source1>][,<source2>]
<source1>, <source2> ::= {CHANnel<n> | FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels) in NR1 format
<r> ::= 1-2 in NR1 format
The :MEASure:DELay command places the instrument in the continuous
measurement mode and starts a delay measurement.
The measurement is taken as:
delay = t(<edge spec 2>) - t(<edge spec 1>)
where the <edge spec> definitions are set by the :MEASure:DEFine command
Query Syntax
:MEASure:DELay? [<source1>][,<source2>]
The :MEASure:DELay? query measures and returns the delay between source1 and
source2. The delay measurement is made from the user-defined slope and edge
count of the signal connected to source1, to the defined slope and edge count of
the signal connected to source2. Delay measurement slope and edge parameters
are selected using the :MEASure:DEFine command.
Also in the :MEASure:DEFine command, you can set upper, middle, and lower
threshold values. It is the middle threshold value that is used when performing the
delay query. The standard upper, middle, and lower measurement thresholds are
NOTE
The :MEASure:DELay command and the front-panel delay measurement differ from the
:MEASure:DELay? query.
The delay command or front-panel measurement run the delay measurement in auto-edge
select mode. In this mode, you can select the edge polarity, but the instrument will select the
edges that will make the best possible delay measurement. The source1 edge chosen will be
the edge that meets the polarity specified and is closest to the trigger reference point. The
source2 edge selected will be that edge of the specified polarity that gives the first of the
following criteria:
•
The smallest positive delay value that is less than source1 period.
• The smallest negative delay that is less than source1 period.
• The smallest absolute value of delay.
The :MEASure:DELay? query will make the measurement using the edges specified by the
:MEASure:DEFine command.










