User Manual

Table Of Contents
342 Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide
20 :MEASure Commands
n/a :MEASure:TEDGe?
<slope><occurrence>[,
<source>] (see
page 373)
<slope> ::= direction of the
waveform
<occurrence> ::= the transition
to be reported
<source> ::= {CHANnel<n> |
FUNCtion | MATH | WMEMory<r> |
EXTernal}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= time in
seconds of the specified
transition
n/a :MEASure:TVALue?
<value>,
[<slope>]<occurrence>
[,<source>] (see
page 375)
<value> ::= voltage level that
the waveform must cross.
<slope> ::= direction of the
waveform when <value> is crossed.
<occurrence> ::= transitions
reported.
<source> ::= {CHANnel<n> |
FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= time in
seconds of specified voltage
crossing in NR3 format
:MEASure:VAMPlitude
[<source>] (see
page 377)
:MEASure:VAMPlitude?
[<source>] (see
page 377)
<source> ::= {CHANnel<n> |
FUNCtion | MATH | WMEMory<r>}
<n> ::= 1 to (# analog channels)
in NR1 format
<r> ::= 1-2 in NR1 format
<return_value> ::= the amplitude
of the selected waveform in volts
in NR3 format
Table 63 :MEASure Commands Summary (continued)
Command Query Options and Query Returns