306 Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide
17 :FUNCtion Commands
:FUNCtion:SOURce1
(see page 782)
Command Syntax
:FUNCtion:SOURce1 <value>
<value> ::= {CHANnel<n> | GOFT}
<n> ::= 1 to (# analog channels) in NR1 format
The :FUNCtion:SOURce1 command is used for any :FUNCtion:OPERation selection
(including the ADD, SUBTract, or MULTiply channel math operations and the FFT
transform). This command selects the first source for channel math operations or
the single source for the transforms.
The GOFT parameter is only available for the FFT function. It lets you specify, as
the function input source, the addition, subtraction, or multiplication of two
channels. When GOFT is used, the g(t) source is specified by the
:FUNCtion:GOFT:OPERation, :FUNCtion:GOFT:SOURce1, and
:FUNCtion:GOFT:SOURce2 commands.
Query Syntax
:FUNCtion:SOURce1?
The :FUNCtion:SOURce1? query returns the current source1 for function
operations.
Return Format
<value><NL>
<value> ::= {CHAN<n> | GOFT}
<n> ::= 1 to (# analog channels) in NR1 format
See Also "Introduction to :FUNCtion Commands" on page 289
":FUNCtion:OPERation" on page 301
":FUNCtion:GOFT:OPERation" on page 297
":FUNCtion:GOFT:SOURce1" on page 298
":FUNCtion:GOFT:SOURce2" on page 299
NOTE
Another shorthand notation for SOURce1 in this command/query (besides SOUR1) is SOUR.