User Manual

Table Of Contents
28 Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide
1 What's New
Command Differences From 2000 X-Series Oscilloscopes
The Keysight InfiniiVision 1000 X-Series oscilloscopes command set is most
closely related to the InfiniiVision 2000 X-Series oscilloscopes (and the
7000 Series, 6000 Series, and 54620/54640 Series oscilloscopes before them).
The main differences between the version 2.50 programming command set for the
InfiniiVision 1000 X-Series oscilloscopes and the 2.40 programming command set
for the InfiniiVision 2000 X-Series oscilloscopes are related to:
You can define a bus made up of analog channels. (There are no digital
channels in the 1000 X-Series oscilloscopes from which to display buses.)
Dedicated FFT function (and selectable math function).
Frequency Response Analysis feature on models with a built-in waveform
generator.
I2C and UART/RS232 serial decode and triggering is supported on all models.
Additionally, CAN, LIN, and SPI serial decode and triggering is supported on
the DSOX1000-Series oscilloscopes.
The Ext Trig input can be displayed as a digital waveform whose high and low
values are determined by the threshold voltage setting.
Waveform event search is not supported.
There is no LAN interface (only USB is supported).
The EDUX1000-Series oscilloscopes do not have the PATTern trigger mode.
The DSOX1000-Series oscilloscopes add the SHOLd (setup and hold) and
TRANsition trigger modes (that were in the 3000 X-Series oscilloscopes).
More detailed descriptions of the new, changed, obsolete, and discontinued
commands appear below.
New Commands
Command Description
:ABUS Commands (see
page 165)
Commands for using buses made up of analog channels.
:DISPlay:MENU:TIMeout (see
page 236)
Sets the softkey menu timeout period.
:EXTernal:DISPlay (see
page 250)
Turns the external trigger input display on or off.
:EXTernal:LABel (see
page 251)
Sets the external trigger input's digital waveform label.
:EXTernal:LEVel (see
page 252)
Sets the external trigger input threshold (trigger) voltage level.
:EXTernal:POSition (see
page 253)
Sets the external trigger input waveform's vertical position.