User Manual

Table Of Contents
:DVM Commands 13
Keysight InfiniiVision 1000 X-Series Oscilloscopes Programmer's Guide 243
:DVM:FREQuency
(see page 782)
Query Syntax
:DVM:FREQuency?
The :DVM:FREQuency? query returns the displayed 5-digit frequency value that is
displayed below the main DVM value.
If the requirements for the DVM FREQuency mode are not met (see ":DVM:MODE"
on page 244), this query will return 9.9E+37.
Return Format
<freq_value><NL>
<freq_value> ::= floating-point number in NR3 format
See Also ":DVM:SOURce" on page 245
":DVM:ENABle" on page 242
":DVM:MODE" on page 244
":DVM:CURRent" on page 241