Datasheet
Page 21
Find us at www.keysight.com
Timer and triggering specification
Timer
Time stamp TIMER value automatically saved when each measurement is triggered
Trigger timing resolution 1 μs to 100 ms
Accuracy ± 50 ppm
Arm/trigger delay 0 μs to 100,000 s
Arm/trigger interval 10 μs to 100,000 s
Arm/trigger event 1 to 100,000
Triggering
1
Digital I/O Trigger in to trigger out ≤ 5 μs
Digital I/O Trigger in to source change ≤ 5 μs
LXI Trigger in to source change Min 100 μs, Typical 200 μs, Max Unknown
LXI Trigger in to measurement Min 100 μs, Typical 200 μs, Max Unknown
Internal event to external LXI trigger output Min 100 µs, Typical 200 µs, Max unknown
LXI event send/receive latency Unknown
Min trigger interval 10 μs
1. Supplemental characteristics
Environmental specifications
Environment For use in indoor facilities
Operating 0 °C to +55 °C, 30 % to 80 % non-condensing
Storage -30 °C to 70 °C, 10 % to 90 % non-condensing
Altitude Operating: 0 m to 2000 m, Storage: 0 m to 4600 m
Power supply 90 V to 264 V, 47 Hz to 63 Hz, 250 VA max
Cooling Forced air. Side intake and rear exhaust.
EMC IEC61326-1/EN61326-1, AS/NZS CISPR 11, KC: RRA Notification amending Radio Waves Act Article 58-2
Safety IEC61010-1/EN61010-1, CAN/CSA-C22.2 No. 61010-1-04, C/US
Certifications CE, cCSAus, C-Tick, KC
Dimensions
Case 88 mm H x 213 mm W x 450 mm D
Working 180 mm H x 260 mm W x 480 mm D (with handle & feet)
Weight
Net 5.0 kg (B2961A), 6.4 kg (B2962A)
Shipping 9.0 kg (B2961A, B2962A)
Front Panel Operation
Front panel interface 4.3" TFT color display (480x272, with LED backlight) with keypads and rotary knob
View mode Single view, Dual view and Graph view
Hardkeys Single Trigger and Auto Trigger control, 10-key, Rotary Knob and Cursors, Channel on/off, View, Cancel/Local
Softkeys Function, System and Input Assist Keys
Indicators Channel (measurement) status, System status
Data Buffers
Max buffer size: 100,000 points / channel