Keysight 3458A Multimeter Shattering performance barriers of speed and accuracy Data Sheet
Performance Highlights DC volts AC volts Frequency and period – 5 ranges: 0.1 V to 1000 V – 8.5 to 4.5 digit resolution – Up to 100,000 readings/sec (4.5 digits) – Maximum sensitivity: 10 nV – 0.
Access Speed and Accuracy Through a Powerful, Convenient Front Panel Display Numeric/user keys – Bright, easy-to-read, vacuum fluorescent display – 16 character alpha-numeric display to easily read data, messages, and commands – Numeric entry for constants and measurement parameters – Shifted keys (f0 through f9) access up to ten user-defined setups Standard function/range keys – Simple to use, for bench measurements of DCV, ACV, ohms, current, frequency and period – Select autorange or manual ranging
A System Multimeter with BOTH High Speed and High Accuracy The Keysight Technologies, Inc. 3458A Multimeter shatters longstanding performance barriers of speed and accuracy on the production test floor, in R&D, and in the calibration lab. The 3458A is simply the fastest, most flexible, and most accurate multimeter ever offered by Keysight.
The 3458A Multimeter for: High test system throughput Faster testing – Up to 100,000 readings/sec – Internal test setups > 340/sec – Programmable integration times from 500 ns to 1 sec Greater test yield – More accuracy for tighter test margins – Up to 8.5 digits resolution Longer up-time – Two-source (10 V,10 kΩ) calibration, including AC – Self-adjusting, self-verifying autocalibration for all functions and ranges, including AC Calibration lab precision Superb transfer measurements – – – – 8.
For High Test System Throughput – Faster system start-up Multimeter Language (ML) compatible – Faster measurements and setups 100,000 readings/sec in 4.5 digits 50,000 readings/sec in 5.
For Calibration Lab Precision – 8.5 digits resolution – 0.1 ppm DCV linearity – 100 ppm ACV absolute accuracy – 4 ppm/year optional stability In the calibration lab, you’ll find the 3458A’s 8.5 digits to have extraordinary linearity, low internal noise, and excellent short term stability. The linearity of the 3458A’s Multislope A to D converter has been characterized with state-of-the-art precision. Using Josephsen Junction Array intrinsic standards, linearity has been measured within ± 0.
For High Resolution Digitizing – 16 bits at 100,000 samples/sec – Effective rates to 100 Msamples/sec – Signal bandwidth of 12 MHz – 10 ns timing with < 100 ps jitter Easily acquire waveforms Direct sampling function Sequential sampling function Simple, application-oriented commands in the Keysight Multimeter Language (ML) make the task of waveform digitizing as easy as measuring DCV. Simply specify the sweep rate and number of samples.
3458A Technical Specifications Section 1: Section 2: Section 3: Section 4: Section 5: Section 6: DC Voltage 10 Resistance 11 DC Current 13 AC Voltage 14 AC Current 19 Frequency/Period 20 Section 7: Section 8: Section 9: Section 10: Section 11: Section 12: Digitizing 21 System Specifications 23 Ratio 24 Math Functions 24 General Specifications 25 Ordering Information 26 Introduction The Keysight 3458A accuracy is specified as a part per million (ppm) of the reading plus a ppm of range for DCV, Ohms, and
Section 1: DC Voltage 10
Section 1: DC Voltage continued Section 2: Resistance 11
Section 2: Resistance continued Measurement Consideration Keysight recommends the use of PTFE* cable or other high impedance, low dielectric absorption cable for these measurements.
Section 3: DC Current Measurement Considerations Keysight recommends the use of PTFE cable or other high impedance, low dielectric absorption cable for low current measurements. Current measurements at rates < NPLC 1 are subject to potential noise pickup. Care must be taken to provide adequate shielding and guarding to maintain measurement accuracies.
Section 4: AC Voltage General Information The Keysight 3458A supports three techniques for measuring true rms AC voltage, each offering unique capabilities. The desired measurement technique is selected through the SETACV command. The ACV functions will then apply the chosen method for subsequent measurements. The following section provides a brief description of the three operation modes along with a summary table helpful in choosing the technique best suited to your specific measurement need.
Section 4: AC Voltage continued 15
Section 4: AC Voltage continued Analog Mode 16 (ACV Function, SETACV ANA)
Section 4: AC Voltage continued Random Sampled Mode (ACV Function, SETACV RNDM) 17
Section 4: AC Voltage continued 18
Section 5: AC Current 19
Section 5: AC Current continued Section 6: Frequency/Period 20
Section 7: Digitizing General Information The Keysight 3458A supports three independent methods for signal digitizing. Each mehtod is discussed below to aid in selecting the appropriate setup best suited to your specific application. DCV Standard DCV function. This mode of digitizing allows signal acquisition at rates from 0.2 readings/sec at 28 bits resolution to 100 k readings/sec at 16 bits. Arbitrary sample apertures from 500 ns to 1 sec are selectable with 100 ns resolution.
Section 7: Digitizing continued Direct and Sub-sampled Digitizing 22 (DSDC, DSAC, SSDC and SSAC Functions)
Section 8: System Specifications 23
Section 9: Ratio Section 10: Math Functions 24
Section 11: General Specifications Operating environment 0 to 55 °C Operating humidity range Up to 95% RH at 40 °C Physical characteristics 88.9 mm H x 425.5 mm W x 502.9 mm D Net weight: 12 kg (26.5 lbs) Shipping weight: 14.8 kg (32.5 lbs) IEEE-4888 interface Complies with the following: IEEE-488.
Section 12: Ordering Information Keysight 3458A multimeter (with GPIB, 20 k bytes reading memory, and 8 ppm stability) 3458A-001 3458A-002 3458A-A6J 3458A-907 3458A-908 3458A-909 3458A-ABD 3458A-ABF 3458A-ABJ 3458A-ABZ Extended reading memory (Expands total to 148 k bytes) High stability (4 ppm/year) reference ANSI Z540 compliant calibration Front handles kit (P/N 5063-9226) Rack mount kit (P/N 5063-9212) Rack mount kit with handles (P/N 5063-9219) German manual French manual Japanese manual Italian manua
| Keysight | 3458A Multimeter - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems.