Datasheet

15
Options & Accessories 34460A / 34461A
Accessories
Accessories included
34460A: Power cord
Calibration certificate
34461A: 34138A test lead set with probes, fine tip probes, SMT grab-
bers and mini grabber attachments
Power cord
Documentation CD
IO Libraries CD
USB cable
Calibration certificate
Accessories available
11059A Kelvin probe set
11060A Surface-mount device probe
11062A Kelvin clip set
34131A Transit case
34133A Precision electronic test leads
34134A DC-coupled current probe
34136A High-voltage probe
34138A Test lead set
34151A Three Signal Wedge Probe Kit
34152A PT100/RTD 4-Wire Class A Sensor Kit
34153A PT100/RTD 4-Wire Class Sensor Elements
34162A Accessory pouch
34171B Input terminal block
34172B Calibration short
34308A Thermistor kit
34330A 30-A current shunt
E2308A Thermistor temperature probe
Y1133A Low-thermal external digital multimeter scanning kit
Options
34460A Digital multimeter, 6½ digit, basic Truevolt DMM
LAN Rear panel LAN/LXI web interface, external triggering for
34460A –
factory enabled
SEC NISPOM and file security for Truevolt Series DMMs – factory
enabled
Z54 Certificate of calibration – ANSI/NCSL Z540.3-2006, printed
GPB GPIB interface module for Truevolt Series DMMs – factory
installed
ACC Accessory kit for 34460A – documentation CDs, test leads,
USB cable; shipped with unit from factory
34461A Digital multimeter, 6½ digit, 34401A replacement, Truevolt DMM
SEC NISPOM and file security for Truevolt Series DMMs – factory
enabled
Z54 Certificate of calibration – ANSI/NCSL Z540.3-2006, printed
GPB GPIB interface module for Truevolt Series DMMs – factory
installed
Standalone product numbers
Ordered as standalone to be installed by the distributor or customer
3446LANU Upgrade:
Enable rear panel LAN/LXI web interface, external triggering for
34460A
3446SECU Upgrade:
Enable NISPOM and file security for Truevolt Series DMMs
3446GPBU Upgrade:
GPIB user-installable interface module for Truevolt Series DMMs
3446ACCU Accessory kit for 34460A:
Documentation CDs, test leads, USB cable
Rack mount kits
34190A Rackmount kit:
Use for mounting one 2U instrument by itself, without another
instrument laterally next to it. Includes one rack flange and one
combination
rack flange-filler panel.
34191A 2U dual flange kit:
Use for mounting two 2U instruments side-by-side.
Includes two standard rack flanges.
Note: Mounting two instruments side-by-side will require the
34194A dual-lock link kit and a shelf for the instruments to sit on.
34194A Dual lock link kit:
For side-by-side combinations of instruments and includes links
for instruments of different depths.
Definitions
Specification (spec)
The warranted performance of a calibrated instrument that has been
stored for a minimum of 2 hours within the operating temperature range of
0 – 55 °C and after a 60-minute warm up period. All specifications include
measurement uncertainty and were created in compliance with ISO-17025
methods. Data published in this document are specifications (spec) only
where specifically indicated.
Typical (typ)
The characteristic performance, which 80% or more of manufactured
instruments will meet. This data is not warranted, does not include
measurement uncertainty, and is valid only at room temperature (approxi-
mately 23 °C).
Nominal (nom)
The mean or average characteristic performance, or the value of an
attribute that is determined by design such as a connector type, physical
dimension, or operating speed. This data is not warranted and is measured
at room temperature (approximately 23 °C).
Measured (meas)
An attribute measured during development for purposes of communicating
the expected performance. This data is not warranted and is measured at
room temperature (approximately 23 °C).
T
CAL
The temperature at which the instrument was calibrated.