Keysight 34461A/34460A Digital Multimeters Discover the next generation of bench/system DMMs from Keysight – Display DMM results in ways you never have before – Measure with unquestioned Truevolt conidence – Move to the next generation 34401A DMM with 100% assurance
Display DMM results in ways you never have before Easily display, save and document your measurement results Easily set up and see your results and get actionable information faster – See your results clearly on a bright, 4.3-inch (109 mm), high-resolution, color graphical display. Get answers faster using the intuitive, menu-driven interface. If you have questions about a key or functionality, press and hold the key to display built-in help on the subject. – Customize display operation to meet your needs.
Display DMM results in ways you never have before Save and document your DMM’s data to your PC or mobile device using your preferred I/O: – Control, capture and view your DMM’s data on your PC with a single click using the Digital Multimeter Connectivity Utility via USB, GPIB, LAN, or RS-232 (for older generation Keysight DMMs). – Easily access the files on your DMM using drag-and-drop to transfer files via USB – no software required.
Measure with unquestioned Truevolt conidence Worry about the quality of your design, not the quality of your measurements In a rack or on a bench real-world signals are never lat. They have some level of AC signal riding on top from power line noise, other environmental noise, or injected current from the meter itself. How well your meter deals with these extraneous factors and eliminates them from the true measurement makes a big difference to your accuracy.
Measure with unquestioned Truevolt conidence What Truevolt technology means to you: You can measure your real-world signals, not instrument error You can measure your real-world signals with conidence Noise and injected current: Keysight Truevolt DMMs contribute less than 30% of the injected current than alternatives. Compared to some lower cost alternatives, Truevolt DMMs offer almost 100% less noise.
Move to the next-generation 34401A DMM with 100% assurance Migrate with conidence: Everything you depend on with the 34401A and more Like most 34401A DMM owners, you rely on your DMM and you trust the answers it gives you. Now, with the Keysight Truevolt 34461A DMM, you can get all of the advantages of the 34401A and more. Now you can get faster answers and have even more conidence in your results. The best news of all? You can migrate from the 34401A to the 34461A without a hassle.
Move to the next-generation 34401A DMM with 100% assurance WHICH MODEL IS RIGHT FOR YOU? 34460A 34461A 34401A Resolution 6½ digits 6½ digits 6½ digits Input terminals Front Front and rear Front and rear 1-year DCV accuracy ±(% of reading + % of range) 0.0075 + 0.0005 0.0035 + 0.0005 0.0035 + 0.
Speciications 34460A 34460A accuracy speciications: ± (% of reading + % of range) 1 These speciication are compliant to ISO/IEC 17025 for K = 2 Range 2/frequency 24 hour 3 TCAL ± 1 °C 90 day TCAL ± 5 °C 1 year TCAL ± 5 °C 2 year TCAL ± 5 °C Temperature coefficient/°C 4 DC voltage 100 mV 1V 10 V 100 V 1000 V 0.0040 + 0.0060 0.0030 + 0.0009 0.0025 + 0.0004 0.0030 + 0.0006 0.0030 + 0.0006 0.0070 + 0.0065 0.0060 + 0.0010 0.0050 + 0.0005 0.0065 + 0.0006 0.0065 + 0.0010 0.0090 + 0.0065 0.0080 + 0.
Speciications 34460A Range 2/frequency 2, 6, 8 True RMS AC current 100 µA, 1 mA, 10 mA, and 100 mA ranges 3 Hz – 5 kHz 5 – 10 kHz 9 1 A range 3 Hz – 5 kHz 5 – 10 kHz 9 3 A range 3 Hz – 5 kHz 5 – 10 kHz 9 DC ratio 90 day TCAL ± 5 °C 1 year TCAL ± 5 °C 2 year TCAL ± 5 °C Temperature coefficient/°C 4 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.015 + 0.006 0.030 + 0.006 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.
Speciications 34461A 34461A accuracy speciications: ± (% of reading + % of range) 1 These speciication are compliant to ISO/IEC 17025 for K = 2 Speciications 34460A 34461A Range 2/frequency 24 hour 3 TCAL ± 1 °C 90 day TCAL ± 5 °C 1 year TCAL ± 5 °C 2 year TCAL ± 5 °C Temperature coefficient/°C 4 DC voltage 100 mV 1V 10 V 100 V 1000 V 0.0030 + 0.0030 0.0020 + 0.0006 0.0015 + 0.0004 0.0020 + 0.0006 0.0020 + 0.0006 0.0040 + 0.0035 0.0030 + 0.0007 0.0020 + 0.0005 0.0035 + 0.0006 0.0035 + 0.0010 0.
Speciications 34461A Range 2/frequency True RMS AC current 2, 6, 8 100 µA, 1 mA, 10 mA, and 100 mA ranges 3 Hz – 5 kHz 5 – 10 kHz 9 1 A range 3 Hz – 5 kHz 5 – 10 kHz 9 3 A range 3 Hz – 5 kHz 5 – 10 kHz 9 10 A range 3 Hz – 5 kHz 5 – 10 kHz 9 90 day TCAL ± 5 °C 1 year TCAL ± 5 °C 2 year TCAL ± 5 °C Temperature coefficient/°C 4 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.015 + 0.006 0.030 + 0.006 0.10 + 0.04 0.10 + 0.04 0.10 + 0.04 0.10 + 0.
Measurement Characteristics 34460A / 34461A Measurement characteristics DC voltage Measurement method: A/D linearity: Input resistance: 0.1 V, 1 V, 10 V range 100 V, 1000 V range Input bias current: Input terminals: Input protection: True RMS AC voltage Measurement type: Measurement method: Maximum input: Input impedance: Input protection: Keysight patented continuously integrating multi-slope IV A/D converter 0.0002% of reading + 0.
Operating Characteristics 34460A / 34461A Performance versus measurement speed For DC voltage, DC current, and resistance 1 34460A Readings/s 0.6 (0.5) 6 (5) 60 (50) 100 300 Digits 6½ 6½ 5½ 5½ 3½ AC voltage, AC current 3, 4 Digits 6½ 6½ 6½ 6½ ACV .4/s 1.6/s 40/s 50/s 5 ACI .6/s 4/s 40/s 50/s 5 Aperture 1 Second 0.1 Second 0.01 Second Digits 7 6 5 Readings 1 10 80 Frequency, period Digits 6½ 6½ 5½ 5½ 4½ 34461A Readings/s 0.6 (0.5) 6 (5) 60 (50) 300 1000 Integration time 100 PLC/1.
General Characteristics 34460A / 34461A 34460A/34461A General characteristics Line power Power supply: 100/120 (127)/ 220 (230)/240 VAC ± 10%, CAT II Power line frequency: 50/60/400 Hz ± 10% Power consumption: 25 VA Environment Operating environment: Operating altitude: Storage temperature: Mechanical Rack dimensions: Bench dimensions: Weight: Regulatory Safety EMC Acoustic noise (nominal) Full accuracy for 0 to 55 °C Full accuracy to 80% R.H.
Options & Accessories 34460A / 34461A Options Standalone product numbers 34460A Digital multimeter, 6½ digit, basic Truevolt DMM LAN Rear panel LAN/LXI web interface, external triggering for 34460A – factory enabled SEC NISPOM and ile security for Truevolt Series DMMs – factory enabled Z54 Certiicate of calibration – ANSI/NCSL Z540.
| Keysight | Digital Multimeters: 34460A & 34461A - Product Brochure myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium.