Datasheet

Page 18
Find us at www.keysight.com
Footnotes
1 Applies to 120 MHz models (33621A/22A) only.
2 DC Offset set to zero.
3 Add 1/10 of the specification per °C for operation at temperatures below 18 °C or above 28 °C.
4 At low amplitude, non-harmonic spurious level is -100 dBm (typ).
5 Measured with a Keysight E5052B signal source analyzer. Phase noise improves by 20 dB/decade as output frequency is decreased.
6 Subject to pulse width limits.
7 Measured with a Keysight E5052B signal source analyzer.
8 Maximum sample rate with Filter "Off" in 160 MSa/s for 80 MHz models and 250 MSa/s for 120 MHz models.
9 Maximum amplitude is less at high frequency for certain waveforms.
10 Counted burst is not available for Gaussian Noise.
11 Subject to amplitude limits.
12 All frequency changes are phase-continuous.
13 External trigger only for sweep time > 8,000 seconds.
14 Measured with a Square or Pulse waveform, edge time set to minimum, and trigger delay set to zero. Trigger latency is generally greater for other
instrument settings. For some waveforms, trigger latency is a function of output frequency.
15 Only available on 33511B/12B/21B/22B models.
16 Only available on 33519B/20B/21B/22B models.
17 Auto range ON.
18 Output noise is typically 20 dB lower when (DC + Peak AC) < 320 mV (into 50 Ω) or 640 mV (into open circuit).
19 Limited to arbitrary waveforms that are < 1 million points, phase resolution limited by number of points in arbitrary waveforms < 3,600 points.
20 Only applies to 33511B/12B/21B/22B and 33611A/12A/21A/22A models.
General characteristics (continued)
Trueform Series 33500B Series 33600A Series
Regulatory
Refer to the Declaration of Conformity
Acoustic noise: Sound pressure level (1-m free-field)(nom) 35 dB(A) at T
AMBIENT
≤ 28 °C
Line power
Line voltage 100 to 240 V, 50/60 Hz
100 to 120 V, 400 Hz
Power consumption < 45 W, < 130 VA < 75 W, < 150 VA