Keysight Technologies 33600A Series Trueform Waveform Generators Data Sheet
02 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Generate Trueform arbitrary waveforms with less jitter, more idelity and greater resolution Revolutionary advances over previous generation DDS Trueform Better Signal Integrity 33600A Series waveform generators with exclusive Trueform signal generation technology offer more capability, idelity and lexibility than previous generation Direct Digital Synthesis (DDS) generators.
03 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet – Easily generate the full range of signals you need for the most demanding measurements – Test your devices with conidence that the waveform generator is outputting the signals you expect – Select just the capabilities you need now, then upgrade easily when your needs change Unique features of the 33600A Series waveform generators 100 MHz PULSE High-bandwidth pulse, 100 MHz, DDS pulse limited to 50 MHz Set leading and trailing edge
04 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Unmatched capabilities for generating a full range of signals for the most demanding requirements The 33600A Series waveform generators offer the common signals and features you expect, such as modulation, sweep and burst. However, it also offers features that give you the capabilities and lexibility you need to get your job done quickly, no matter how complex.
05 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Capabilities (continued) While DDS technology may skip points at higher frequencies, Trueform never skips points, and is always anti-aliased Deine any waveform shape and any waveform length using the Trueform arbitrary waveform capability. Your waveforms are always anti-aliased for exceptional accuracy, and you can play them at any rate you select.
06 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Capabilities (continued) Pseudo-random binary sequence (PRBS) pattern generation Easily generate PRBS waveforms on the 33600A Series waveform generators. Test your digital serial buses by streaming standard PRBS patterns—PN3 through PN32—without the need for a separate pulse generator. With fewer instruments, setting up your tests has never been easier. You won’t ind these built-in PRBS patterns in competitive waveform generators.
07 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Capabilities (continued) Built-in Web browser Easily set up and control your 33600A Series generator remotely over a LAN connection using the built-in LXI Web browser. You can monitor your tests and adjust settings from another ofice or room, or even from home.
08 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Signal integrity: test your devices with conidence that your signal generator is outputting the signals you expect If your generator is introducing spurious signals or harmonics, you’ll have a hard time producing reliable designs. To be successful, you need to test with clean, precise, low-noise signals.
09 | Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Signal Integrity (continued) Reproduce lower-voltage output signals Today’s ultra-low-power products such as pacemakers, hearing aids and remote sensors use very low voltages. The 33600A Series lets you create signals as low as 1 mVpp. That’s a 10x lower voltage range than typical waveform generators. High-bandwidth pulses Create pulses up to 100 MHz with the 33600A Series.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Select the capabilities you need now, then upgrade easily when your needs change Investment protection With most waveform generators, you get only what you pay for when you buy your instrument. But with 33600A Series waveform generators, there are four different models to choose from so you can purchase the capability you need now and upgrade later when your project needs change. Your investment in test equipment is protected.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet 4 models to choose from Choose the model with the capability you need now, knowing you can upgrade later. All models come with a rich set of built-in, standard features, including LAN, USB and optional GPIB interfaces, 4 MSample of memory, an external timebase input, and basic waveform generation software. You get everything you need to generate clean, precise, low-noise signals for testing your designs.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet 33600A Series Trueform Waveform Generator Test Challenges Generating the signals you need for your measurements can be a tedious and time-consuming task, one that’s often complicated by uncertainty whether your signal generator is outputting the signals you expect.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Other Productivity Tools Keysight BenchLink Waveform Builder Pro Software Easily create custom waveforms with advanced waveform creation and editing software Get advanced signal creation/editing capability without tedious programming with optional 33503A BenchLink Waveform Builder Pro software.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Coniguration Guide Step 1. Choose your bandwidth and channel count 33600A Series waveform generators with Trueform technology Bandwidth 80 MHz 80 MHz 120 MHz 120 MHz Number of channels 1 2 1 2 Waveform generator 33611A 33612A 33621A 33622A Step 2.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Speciications Unless otherwise stated, all speciications apply with a 50-Ω resistive load and automatic amplitude range selection enabled.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Waveform characteristics (continued) Square & pulse Frequency ranges VOUT ≤ 10 Vpp VOUT ≤ 4 Vpp Rise & fall time (nom) VOUT ≤ 4 Vpp VOUT > 4 Vpp Overshoot (typ) VOUT ≤ 4 Vpp VOUT > 4 Vpp Duty cycle 6 Pulse width VOUT ≤ 4 Vpp VOUT > 4 Vpp Jitter (rms) (meas) 7 10-Hz to 40-MHz band Ramp & triangle Frequency range Ramp symmetry Nonlinearity (typ) Gaussian noise Variable bandwidth (nom) VOUT ≤ 10 Vpp VOUT ≤ 8 Vpp VOUT ≤ 4 Vpp Crest factor
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Waveform characteristics (continued) Arbitrary waveform sequencing Operation Individual arbitrary waveforms (segments) can be combined into user-deined lists (sequences) to form longer, more complex waveforms. Each sequence step speciies whether to repeat the associated segment a certain number of times, to repeat it indeinitely, to repeat it until a Trigger event occurs, or to stop and wait for a Trigger event.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Speciications Modulating signals Carrier Sine Square Ramp Triangle Noise PRBS Arbitrary External Sine • • • • • • • • Square & pulse • • • • • • • • Ramp & triangle • • • • • • • • Gaussian noise • • • • • • • PRBS • • • • • • • Arbitrary • • • • • • • Modulation, burst, and sweep characteristics Amplitude modulation (AM) Source Internal or external (all models), or other ch
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Speciications (continued) Modulation, burst, and sweep characteristics, continued Sweep characteristics12 Type Linear, Logarithmic, or List (up to 128 user-deined frequencies) Operation Linear and Logarithmic sweeps are characterized by a Sweep time (during which the frequency changes smoothly from Start to Stop), a Hold time (during which the frequency stays at the Stop frequency), and a Return time (during which the frequency cha
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Speciications (continued) Modulation input Connector Rear-panel BNC, shell and pin isolated from chassis (±42 V maximum) Assignment Channel 1, Channel 2, or both Voltage level (nom) ±1 V or ±5 V full scale, selectable Input Impedance (nom) 5 kΩ Bandwidth (−3 dB) (typ) 0 Hz to 100 kH External trigger/gate input/output General characteristics Connector Assignment: Input Output Polarity Maximum Rate Input characteristics Thresh
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Speciications (continued) Programming times Coniguration changes (meas) LAN (socket) LAN (VXI-11) USB 2.0 GPIB Change function (meas) 29.2 ms 29.7 ms 29.4 ms 29.2 ms Change frequency (meas) 2.7 ms 3.3 ms 2.8 ms 2.7 ms Change amplitude (meas) 8.3 ms 9.0 ms 8.3 ms 8.3 ms Select Arb. waveform (16 k samples)(meas) 12.7 ms 13.9 ms 13.1 ms 12.
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Speciications (continued) General characteristics (continued) Environmental Storage temperature –40 to 70 ºC Warm-up time 1 hour Operating environment EN61010, pollution degree 2, indoor locations Operating temperature 0 to 55 ºC Operating humidity 5% to 80% RH, non-condensing Operating altitude < 3000 meters Regulatory Refer to the Declaration of Conformity Sound pressure level (1-m free-ield) (nom) 35 dB(A) at TAMBIENT
| Keysight | M33600A Series Trueform Waveform Generators - Data Sheet Deinitions Speciication (spec) The warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range of 0 to 55 ºC and after a 1-hour warm up period. All speciications account for the effects of measurement and calibration-source uncertainties, and were created in compliance with ISO-17025 methods.
| Keysight | 33600A Series Trueform Waveform Generators - Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium.