Agilent U8000 Series Single Output DC Power Supplies Data Sheet
Key Features Excellent load and line regulation: (CV: <0.01% +2 mV; CC: <0.02% + 2mA) Low output noise: 1 mVrms (20 Hz to 20 MHz) Over Voltage and Over Current Protection LCD display with backlight capability Standby output for safety purposes Save-and-recall function up to three memory states Security features: keypad lock and physical lock mechanism Figure 1.
Work Efficiently with Great Features and Solid Performance — Within Budget Differentiated features typically found only in programmable power supplies The U8000 Series offers fully integrated over voltage protection (OVP) and over current protection (OCP) to prevent damage to the device-under-test (DUT). Using the capability to save and recall three memory states, you can minimize errors and reduce set-up time.
Features of the U8000 Series Fully integrated over voltage and over current protection to prevent damages to the DUT Three storage locations (M1, M2, and M3) for user-defined operating states with save-and-recall capability Setting and display of the voltage and current limit values Rotary knob for quick and analog-like control of voltage and current Highly visible LCD displaying actual values of output voltage and current in meter mode and limit values of voltage and current in limit mode Versatile bin
Performance Specifications Electrical Specifications Parameter Output Ratings (at 0 °C to 40 °C) U8001A U8002A 0 to +30 V 0 to 3 A 0 to +30 V 0 to 5 A Line and Load Regulation CV: <0.01% +2 mV CC: <0.02% +2 mA Ripple and Noise (25 °C ±5 °C) CV: 12 mVp-p, <1 mVrms; CC: 3 mArms Load Transient Response Time (within 15 mV from full load to half load and from half load to full load) <50 μs Programming Accuracy1 (25 °C ±5 °C) <0.35% +20 mV <0.35% +20 mA Readback Accuracy1 (25 °C ±5 ° C) <0.
Supplemental Characteristics Supplemental Characteristics Parameter U8001A Temperature Coefficient (for 12 months) U8002A CV: <100 ppm/ °C CC: <380 ppm/ °C Output Voltage Overshoot (during turn-on or turn-off of AC power state with the output control set to less than 1 V) CC: <300 ppm/ °C <1 V Voltage Programming Speed, to within 1% of total excursion Up Full Load No Load 150 ms 100 ms Down Full Load No Load 30 ms 450 ms Last Memory Setting Enabled Yes Over Voltage Protection Response Time <1.
General Characteristics Display Calibration Cycle Other Options Liquid Crystal Display (LCD) One year Operating Environment Warm-up time 2SWLRQ 8 [$ $87 &XVWRP Power On E3600A-100 Test lead kit Option 1CM Rack-mount kit 2SHUDWLQJ WHPSHUDWXUH IURP & WR 40 °C (for full rated output) and 40 °C to 55 °C (for derated output) Relative humidity up to 95% Altitude up to 2000 meters 60 minutes Storage Compliance U8001A DC Power Supply, 30 V, 3 A U8002A DC Power Supply, 30 V, 5 A
www.agilent.com Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products.