Agilent USB Modular Products Data Sheet Introduction Agilent´s compact USB modular products are a series of modules that are flexible to be used standalone or plugged into a compatible chassis to make synchronized measurements as a modular unit. Essential measurements can be made with a laptop PC and these modules through USB high-speed 2.0 connections. Through individual windows, the Agilent Measurement Manager (AMM) software provides a friendly soft front-panel interface for each of the modular products.
Overview Table of Contents Agilent U2781A USB Modular Product Chassis Overview ........................................................................................2 Agilent U2781A USB Modular Product Chassis .....................6 Agilent Measurement Manager ............................................. 11 Agilent USB Modular Data Acquisition Modules ............... 12 U2300A Series USB Modular Multifunction Data Acquisition Devices ..............................................................
Agilent USB Modular Data Acquisition (DAQ) Family U2300A Series USB Modular Multifunction DAQ U2600A Series USB Modular Isolated Digital I/O Features: • High analog input sampling rate coverage of up to 3 MSa/s for a single channel • High analog input up to 64 channels • High speed USB 2.0 • Multifunction capabilities — analog input (AI), analog output (AO), digital input output (DIO), and counter Features: • 64 opto-isolated lines that can meet demand up to 24 V • High speed USB 2.
Agilent USB Modular Test Instruments Family U2722A/U2723A USB Modular Source Measure Unit U2701A/U2702A USB Modular Oscilloscope Features: • High sampling rate up to 500 MSa/s, enables accurate measurement analysis • Up to 32 MB large memory • Fast fourier transfer (FFT) and waveform math functions enables easy waveform calculation Features: • Four-quadrant source/measure operation • 16-bit resolution for all voltage and current ranges with high measurement sensitivity • High accuracy • Embedded test scr
Ease of Use Compatible with a Wide Range of Application Development Environments The Agilent USB modular products are equipped with Hi-Speed USB 2.0 interfaces for easy setup, plug-and-play, and hot swappable connectivity. With the quick and easy USB connectivity, the USB modular products are simple enough for academic applications and yet robust and versatile enough for industrial laboratory applications.
Agilent U2781A USB Modular Product Chassis Features Introduction • Internal and external 10 MHz reference clock The Agilent U2781A USB modular product chassis is a high-performance 4U chassis that comes with a 200 W universal AC power supply and a built-in protection circuit. This portable chassis can house up to six Agilent USB modular products.
High-density data acquisition Triggering using Star trigger bus The U2781A chassis increases the number of available channels when any U2300 Series, U2500 Series, or U2600 Series products are slotted into the chassis. For example, when you slot six U2331A Series products in the chassis, it allows for an expansion of up to 384 channels, providing a highdensity data acquisition solution.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[5] POWER CONSUMPTION • 400 VA maximum • Installation Category II OPERATING ENVIRONMENT • Operating temperature from 0 °C to +55 °C • Operating humidity at 15% to 85% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only Rear view STORAGE COMPLIANCE –20 °C to 70 °C 197.
Electrical specifications Power supply AC input Input voltage range 100 to 240 VAC Input frequency range 50 to 60 Hz Power consumption 400 VA maximum Efficiency 75% Power supply DC output Output rated voltage 12 VDC Max output rated current 16.7 A Max output rated power 200 W Over voltage protection 13.2 to 16.
Mechanical specifications Physical layout Number of USB module slots 6 Dimension of each module slot 25.40 mm (W) x 174.54 mm (D) x 105.00 mm (H) Dimension of chassis 270.00 mm (W) x 271.20 mm (D) x 197.00 mm (H) Weight 3.
Agilent Measurement Manager The Agilent Measurement Manager (AMM) is an application software that comes with the standard purchase of the U2300A Series, U2500A Series, U2600A Series USB modular DAQ, or U2700A Series USB modular instruments. The AMM is also bundled with the U2781A USB modular product chassis. This software is designed to help you perform quick device configuration, data logging, and data acquisition through the products.
Agilent USB Modular Data Acquisition Modules The USB data acquisition (DAQ) family gives you the choice and flexibility to create solutions that evolve and expand according to your changing measurement needs. You can quickly and easily acquire, measure, and analyze data from electrical, mechanical, physical, and acoustical phenomena. The DAQ series includes multifunction measurement modules, simultaneous-sampling measurement modules, two types of digital input/output (DIO) devices, and a thermocouple input.
U2300A Series USB Modular Multifunction Data Acquisition Devices Features Introduction • Up to 3 MSa/s sampling rate for a single channel The Agilent U2300A Series USB modular multifunction data-acquisition (DAQ) devices offer a high-performance PC data-acquisition solution. The U2300A Series DAQ devices consist of two families: basic multifunction DAQ and highdensity multifunction DAQ.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER REQUIREMENT • +12 VDC (TYPICAL) • 2 A (MAX) input rated current Rear view POWER CONSUMPTION +12 VDC, 550 mA maximum OPERATING ENVIRONMENT • Operating temperature from 0 °C to +55 °C • Relative humidity at 15% to 85% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only 44.
Electrical specifications Basic multifunction USB DAQ Model number U2351A U2352A U2353A U2354A Analog input Resolution 16 bits, no missing codes Number of channels 16 SE/8 DI (software selectable/channel) Maximum sampling rate[1] 250 kSa/s Scan list memory 500 kSa/s Up to 100 selectable channel entries Programmable bipolar input range ±10 V, ±5 V, ±2.5 V, ±1.25 V Programmable unipolar input range 0 to 10 V, 0 to 5 V, 0 to 2.5 V, 0 to 1.
Basic multifunction USB DAQ (continued) Digital I/O Number of channels 24-bit programmable input/output Compatibility TTL Input voltage VIL = 0.7 V max, IIL = 10 μA max VIH = 2.0 V min, IIH = 10 μA max Input voltage range –0.5 V to +5.5 V VOL = 0.45 V max, IOL = 8 mA max VOH = 2.
High density multifunction USB DAQ Model number U2355A U2356A U2331A Analog input Resolution 16 bits, no missing codes Number of channels Maximum sampling rate[1] 64 SE/32 DI (software selectable/channel) 250 kSa/s Programmable unipolar input range Up to 100 selectable channel entries ±10 V, ±5 V, ±2.5 V, ±1.25 V ±10 V, ±5 V, ±2.5 V, ±1.25 V, ±1 V, ±0.5 V, ±0.25 V, ±0.2 V, ±0.05 V 0 to 10 V, 0 to 5 V, 0 to 2.5 V, 0 to 1.25 V 0 to 10 V, 0 to 5 V, 0 to 4 V, 0 to 2.5 V, 0 to 2 V, 0 to 1 V, 0 to 0.
High density multifunction USB DAQ (continued) General purpose digital counter Maximum count (2³¹ – 1) bits Number of channels Two independent up/down counter Compatibility TTL Clock source Internal or external Base clock available 48 MHz Maximum clock source frequency 12 MHz Input frequency range[4] 0.1 Hz to 6 MHz at 50% duty cycle Pulse width measurement range 0.167 μs to 178.
Electrical measurement specifications Basic multifunction USB DAQ Model number U2351A, U2352A U2353A, U2354A [1] Analog input measurement Function 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 45 °C 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 45 °C ±1 mV ±5 mV ±1 mV ±5 mV ±2 mV ±5 mV ±2 mV ±5 mV Offset error Gain error [2] –3 dB Small signal bandwidth 760 kHz 1.5 MHz 1% THD Large signal bandwidth[2] 300 kHz 300 kHz System noise 1 mVrms 2 mVrms 1 mVrms 2.
High density multifunction USB DAQ Model number U2355A U2356A U2331A Analog input measurement[1] Function 23 °C ± 5 °C Offset error ±1 mV Gain error ±2 mV –3 dB small signal bandwidth[2] 0 °C to 18 °C 28 °C to 45 °C ±2 mV ±1 mV ±3 mV ±2 mV 760 kHz 1% THD large signal bandwidth[2] 1 mVrms CMRR 23 °C ± 5 °C ±2 mV ±2 mV ±6 mV ±6 mV 1.3 MHz 400 kHz System noise 0 °C to 18 °C 28 °C to 45 °C 23 °C ± 5 °C ±3 mV ±7.5 mV 1.
High density multifunction USB DAQ (continued) Model number U2355A, U2356A U2331A Analog output measurement[1] 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 45 °C 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 45 °C Offset error ±1 mV ±4 mV ±1.5 mV ±3 mV Gain error ±4 mV ±5 mV ±4 mV Function ±5 mV Slew rate 19 V/μs 19 V/μs Rise time 0.9 μs 0.9 μs Fall time 0.9 μs 0.
DC Characteristics Accuracy Specifications Model Number U2351A, U2352A, U2353A, U2354A Analog Input Unipolar Range (V) Offset Error (mV)[1] Accuracy (% of reading + offset error)[2] Gain Error (mV) 10 1.5 2.0 0.04% + 1.5 mV 5 1.5 2.0 0.08% + 1.5 mV 2.5 1.0 1.0 0.08% + 1.0 mV 1.25 1.0 1.0 0.16% + 1.0 mV Bipolar Range (V) [1] Accuracy (% of reading + offset error)[2] Gain Error (mV) Offset Error (mV) 10 1.0 2.0 0.02% + 1.0 mV 5 1.0 2.0 0.04% + 1.0 mV 2.5 1.0 1.5 0.06% + 1.
Accuracy Specifications (Continued) Model U2331A Bipolar Range (V) Offset Error (mV)[1] Gain Error (mV) Accuracy (% of reading + offset error)[2] 10 2.0 6.0 0.06% + 2.0 mV 5 1.5 4.0 0.08% + 1.5 mV 2.5 1.5 2.0 0.08% + 1.5 mV 1.25 1.0 1.5 0.12% + 1.0 mV 1 1.0 1.0 0.10% + 1.0 mV 0.5 1.0 1.0 0.20% + 1.0 mV 0.25 1.0 1.0 0.40% + 1.0 mV 0.2 1.0 1.0 0.50% + 1.0 mV 0.05 1.0 1.0 2.02% + 1.0 mV • The above specifications are typical for 23 °C.
U2500A Series USB Modular Simultaneous Sampling Multifunction DAQ Devices Features Introduction • Simultaneous sampling with up to 2 MSa/s sampling rate for each channel The Agilent U2500A Series USB simultaneous sampling multifunction data acquisition (DAQ) devices are high-performance modules that consist of three models — the U2531A, U2541A, and U2542A. The U2500A Series provides up to four channels with resolutions of 14-bit and 16-bit.
Product outlook and dimensions Front view Product characteristics and General Specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER REQUIREMENT • +12 VDC (TYPICAL) • 2 A (MAX) input rated current • Installation Category II Rear view POWER CONSUMPTION +12 VDC, 480 mA maximum 44.
Product specifications Model number U2531A U2541A U2542A Analog input Resolution 14 bits Number of channels 16 bits 4 differential input channels (software selectable/channel) Maximum sampling rate 2 MSa/s 250 kSa/s [1] Programmable bipolar input range ±10 V, ±5 V, ±2.5 V, ±1.25 V Programmable unipolar input range 0 to 10 V, 0 to 5 V, 0 to 2.5 V, 0 to 1.25 V Input coupling 500 kSa/s DC Input impedance 1 GΩ/100 pF Operational common mode voltage range Overvoltage range ±8.
Product specifications (continued) Model number U2531A U2541A U2542A Analog trigger Trigger source All analog input channels, External analog trigger (EXTA_TRIG) ±Full scale for internal ±10 V for external Trigger level Trigger conditions Above high, below low, and window (software selectable) Trigger level resolution 8 bits Bandwidth 400 kHz Input impedance for EXTA_TRIG 20 kΩ Coupling DC Overvoltage protection Continuous for ±35 V maximum Digital trigger Compatibility TTL/CMOS Response
Electrical specifications and characteristics Analog input characteristics[1] Model number Offset error[2] [2] Gain error U2531A U2541A 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 55 °C ±2 mV ±6 mV U2542A 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 55 °C 23 °C ± 5 °C 0 °C to 18 °C 28 °C to 55 °C ±2 mV ±1 mV ±1 mV ±1 mV ±1 mV ±6 mV ±2 mV ±2.5 mV ±2 mV ±2.5 mV –3 dB Small signal bandwidth 1.2 MHz 600 KHz 1.0 MHz 1% THD Large signal bandwidth 400 KHz 400 KHz 400 KHz [3] 2.0 mVrms 0.5 mVrms 0.
Test condition Dynamic range test for U2500A Series DAQ devices Dynamic range test SFDR, THD, SINAD, SNR, ENOB Model Test conditions (DUT setting at ±10 V bipolar) U2531A • • • • Sampling rate: Fundamental frequency: Number of points: Fundamental input voltage: 2 MSa/s 19.927 kHz 65536 FSR –1 dB FS U2541A • • • • Sampling rate: Fundamental frequency: Number of points: Fundamental input voltage: 250 kSa/s 2.
Typical performance graph 30
DC characteristics Accuracy specifications[1] Model U2541A, U2542A Analog input Unipolar range (V) Offset error (mV)[2] Gain error (mV) Accuracy (% of reading + offset error)[3] 10 1.0 1.0 0.02% + 1.0 mV 5 1.0 1.0 0.04% + 1.0 mV 2.5 1.0 1.0 0.08% + 1.0 mV 1.25 1.0 1.0 0.16% + 1.0 mV 10 1.0 2.0 0.02% + 1.0 mV 5 1.0 1.0 0.02% + 1.0 mV 2.5 1.0 1.0 0.04% + 1.0 mV 1.25 1.0 1.0 0.08% + 1.
U2600A Series USB Modular Isolated Digital I/O Devices Features Introduction • Hi-Speed USB 2.0 (480 Mbps) Functions as standalone or modular unit The Agilent U2600A Series USB isolated digital I/O devices are highperformance modules that consist of three models— the U2651A isolated 32-bit DI and 32-bit DO, U2652A isolated 64-bit DI, and U2653A isolated 64-bit DO. The U2600A Series provides up to eight channels with 64-bit of high-density optoisolated digital input and digital output for USB 2.
High channel count with opto-isolated digital input and digital output The U2600A Series has high channel count with up to 64-bit high-density opto-isolated digital input and digital output that increases its usability. With just one DIO device, you are able to drive more actuators and control more sensors. Furthermore, opto-isolation separates the electrical connection between circuits for better PC system protection.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER REQUIREMENT • +12 VDC (TYPICAL) • 2 A (MAX) input rated current • Installation Category II Rear view POWER CONSUMPTION +12 VDC, 260 mA maximum 44.
Product specifications Model number U2651A U2652A U2653A Digital input Number of isolated bits 32-bit 64-bit - Opto-isolated Opto-isolated - Maximum input voltage range[1] 24 V, non-polarity 24 V, non-polarity - Digital logic levels[2] High: 10 V to 24 V Low: 0 V to 2 V High: 10 V to 24 V Low: 0 V to 2 V - Input resistance 24 kW at 0.75 W 24 kW at 0.75 W - 1.5 mA per bit 1.5 mA per bit - 1250 Vpeak 1250 Vpeak - DI_101.0/301 and DI_101.1/302 DI_101.0/301 and DI_101.
U2802A 31-Channel Thermocouple Input Device Features Introduction • Up to 31 thermocouple inputs The Agilent U2802A is a 31-channel thermocouple signal conditioning module with a built-in thermistor for cold junction compensation. The U2802A is designed to convert low input voltage signals (less than ±100 mV) from a thermocouple into an output voltage range suitable for data acquisition devices (±10 V).
Thermocouple input mode Open thermocouple detection In thermocouple input mode, the U2802A can acquire up to ±100 mV input signals. Each channel includes an instrumentation amplifier and a 4 Hz low-pass filter. The low-pass filter removes unwanted noise from the thermocouple wires to obtain accurate measurement data. The U2802A includes open thermocouple detection circuitry to indicate the presence of an open thermocouple.
Product outlook and dimensions Front view Product characteristics and general specifications POWER CONSUMPTION +12 VDC, 480 mA maximum OPERATING ENVIRONMENT • Operating temperature from 0 °C to +55 °C • Relative humidity at 50% to 85% RH (non-condensing) • Altitude up to 2000 meters Rear view STORAGE COMPLIANCE –40 °C to 70 °C 40.
Product specifications General characteristics Number of channels 31 differential and 1 CJC Input voltage range for voltage mode ±10 V (signal + common mode) Input voltage (thermocouple mode) ±100 mV Sampling rate for thermocouple mode 10 kSa/s total for all channels Sampling rate for overall module 500 kSa/s Thermocouple types J, K, R, S, T, N, E, and B Input specifications Accuracy (thermocouple mode) • Overall gain error • Overall offset error • Nonlinearity 0.
Thermocouples typical measurement accuracy The U2802A measurement error with U2355A or U2356A at 23 °C ± 5 °C is shown below.
System accuracy specifications The U2802A system accuracy specifications are shown in Table 1, Table 2, and Table 3. These measurements are derived from the U2802A and DAQ input accuracy specifications without including the thermocouple error. Refer to “Calculating System Accuracy” section in the Agilent U2802A 31-Channel Thermocouple Input Device User’s Guide for calculation methodology. Table 1.
Table 3. Measurement accuracy of the U2356A at 0 to 18 °C and 28 to 45 °C Thermocouple measurement accuracy (U2356A @ 0 to 18 °C and 28 to 45 °C) T/C type B ITS-90 Temperature range (°C) 0 1820 1100 1820 6.1 3.1 2.4 400 1100 14.4 6.3 2.7 –150 1000 3.0 2.6 2.6 –200 –150 4.2 3.7 3.6 –150 1200 2.9 2.5 2.5 –210 –150 4.9 4.1 4.
Optional Acessories for USB Modular DAQ Introduction The U2901A/U2902A is a terminal block and SCSI-II 68-pin connector with 1 meter cable or 2 meter cable that can be used conjunction with the U2300A Series and U2500A Series. U2901/U2902A — Terminal block and SCSI-II 68-pin connector with 1-meter/2-meter cable Terminal block overview Front view The U2903A/U2904A is a terminal block and SCSI-II 100-pin connector with 1 meter cable or 2 meter cable are that can be used conjunction with the U2600A Series.
U2903/U2904A - Terminal block and SCSI-II 100-pin connector with 1-meter/2-meter cable Terminal block overview Front view 85.20 mm 103.00 mm Side view 42.96 mm 28.
Agilent USB Modular Test Instrument Modules Agilent´s growing family of USB-based modular test instruments now includes oscilloscopes, a function generator, source measure unit, switch matrix, and a digital multimeter while the series of data acquisition family consists of numerous modules. This makes electronic functional test, troubleshooting, data logging, and measurement effortless. These devices offer the flexibility of standalone or modular operation for easy, affordable measurements and analysis.
U2701A and U2702A USB Modular Oscilloscope Features • 100 MHz and 200 MHz bandwidths • Up to 1GSa/s maximum sample rate • 32 Mpts of waveform memory • Compact and portable size — 117.00 mm × 180.00 mm × 41.00 mm (with rubber bumpers) • Advanced triggering, including edge, pulse width, and TV • Compatibility with Hi-Speed USB 2.
Why do you need Deep Memory and a High Sampling Rate? To see more time Ease of use The U2701A and U2702A USB modular oscilloscopes are equipped with HiSpeed USB 2.0 interface for easy setup and plug-and-play. Hence, this ease-of use makes the oscilloscopes ideal for the education, design validation, and manufacturing environment. When you are able to store more samples that you have obtained in the memory, you can view the signal at a longer time.
Features you need The U2701A and U2702A includes the following standard features that you need to perform your tasks efficiently: Hi-Speed USB Interface The U2701A and U2702A connect to the computer through Hi-Speed USB 2.0 connectivity. Autoscale Autoscale lets you display any active signals, automatically setting the vertical, horizontal, and trigger controls for the best signal display within the shortest time.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC 488.2 Class device POWER CONSUMPTION • +12 VDC, 2 A • Installation Category III Rear view OPERATING ENVIRONMENT • Operating temperature from 0 °C to +50 °C • Operating humidity at 20% to 85% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only 41.00 mm Top view 117.
Performance specifications[1] Vertical system: oscilloscope channels Bandwidth (–3 dB) U2701A: DC to 100 MHz U2702A: DC to 200 MHz Scope channel triggering Trigger sensitivity < 10 mV/div: greater of 1 div or 5mV; ≥10 mV/div: 0.
Performance characteristics[1] (continued) Vertical system: oscilloscope channels (continued) Single-cursor accuracy ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~½ LSB)} Example: For 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, Accuracy = ±{4.0% (80 mV) + 0.1(10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2% (80 mV)} = ±6.385 mV Dual-cursor accuracy ±{DC vertical gain accuracy + 0.
Performance characteristics[1] (continued) External (EXT) triggering (continued) Trigger level sensitivity For ±1.25 V range setting: DC to 100 MHz: 100 μV > 100 MHz: 200 μV For ±2.5 V range setting: DC to 100 MHz: 250 μV > 100 MHz: 500 μV Display Interpolation Sin(x)/x Display types Dots and vectors Persistence Off, infinite Format XY, roll Measurement features Automatic measurements Measurements are continuously updated. Cursors track last selected measurement.
U2722A/U2723A USB Modular Source Measure Unit Features Introduction • Three-channel SMU The Agilent U2722A/U2723A USB modular source measure unit is more than just a power supply – it has fast response time, and has voltage and current programming/readback with high accuracy measurement capabilities. The U2722A and its enhanced version, the U2723A are capable of four-quadrant operation, acting as current source and also as current sink (load) with both polarities of the output voltage.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER CONSUMPTION • +12 VDC, 3 A maximum • Isolated ELV supply source OPERATING ENVIRONMENT • Operating temperature from 0 °C to +50 °C • Relative humidity at 20% to 85% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only Rear view 66.
Product specifications General Model U2722A/U2723A Number of outputs 3 Output ratings (at 0 °C to 50 °C) Voltage –20 V to 20 V Current –120 mA to 120 mA Performance specification U2722A/U2723A Range Accuracy[1] Resolution Voltage programming 12 months (at 25 °C ± 3 °C), ±(% of output + offset) ±2 V 0.075% + 1.5 mV 0.1 mV ±20 V 0.05% + 10 mV 1 mV ±1 μA 0.085% + 0.
Performance characteristics Rise/fall time (ms)[1] For resistive measurement[2] U2722A U2723A ±1 μA 170.0 15.0 ±10 μA 18.0 5.0 ±100 μA 6.0 1.0 ±1 mA 1.0 1.0 ±10 mA 1.0 1.0 ±120 mA 1.0 1.0 Remote sense operating range Ensure that the maximum voltage between the OUTPUT+ and SENSE+, OUTPUT–, and SENSE– does not exceed 3 V. Temperature coefficient Maximum change in output/readback per °C after a 30-minute warm-up is 0.15. Guard output resistance 0.
U2741A USB Modular Digital Multimeter Features Introduction • Makes fast measurements with up to 100 readings per second The Agilent U2741A is a 5½-digits digital multimeter (DMM), which is the latest addition to the Agilent’s USB modular family. It can operate as standalone or as a modular unit when used with the U2781A USB modular product chassis. It comes with various features and functions to meet your needs today.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER CONSUMPTION • +12 VDC, 2 A maximum • Isolated ELV supply source Rear view OPERATING ENVIRONMENT • Operating temperature from 18 °C to +28 °C • Relative humidity at 50% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only 41.00 mm Top view 117.
Product specifications DC specifications[1] Function [2] Voltage Current[3] Resistance[4] [5] Diode test Continuity test[6] NOTE Accuracy ±(% of reading + % of range) Temperature coefficient 0 °C to 18 ºC 28 °C to 55 °C Range Input impedance Test current/ Burden voltage, Shunt resistance 100.000 mV 10 MΩ - 0.015 + 0.008 0.002 + 0.0008 1.00000 V 10 MΩ - 0.015 + 0.005 0.001 + 0.0005 10.0000 V 10 MΩ - 0.018 + 0.005 0.002 + 0.0005 100.000 V 10 MΩ - 0.018 + 0.005 0.002 + 0.
AC specifications[1] AC accuracy for voltage Function Accuracy input ±(% of reading + % of range) Frequency (Hz) Range 20 ~ 45 Voltage[2] 45 ~ 10k 10k ~ 30k 30k ~ 100k[3] 100.000 mVrms 1 + 0.1 0.2 + 0.1 1.5 + 0.3 5.0 + 0.3 1.00000 V 1 + 0.1 0.2 + 0.1 1.0 + 0.1 3.0 + 0.2 10.0000 V 1 + 0.1 0.3 + 0.1 1.0 + 0.1 3.0 + 0.2 100.000 V 1 + 0.1 0.3 + 0.1 1.0 + 0.1 3.0 + 0.2 1 + 0.1 0.3 + 0.1 1.0 + 0.1 3.0 + 0.2 [4] 250.
Frequency specifications[1] Frequency accuracy Function Range Accuracy (% of reading + % of range) Minimum input frequency Temperature coefficient (% of range) Frequency 20 Hz to 300 kHz 0.0200 + 0.003 1 Hz 0.005 Frequency Sensitivity for AC Voltage Function Minimum sensitivity (RMS sine wave) Frequency (Hz) Range 20 ~ 100k 100k ~ 300k 20 mV 20 mV 1 V 100 mV 120 mV 10 V 1V 1.
Test Range/NPLC 20 10 2 1 0.025 0 DCV 100 mV 0.413 0.213 0.053 0.033 0.016 0.016 DCI 2W 4W 1V 0.414 0.213 0.053 0.033 0.016 0.016 10 V 0.413 0.213 0.053 0.033 0.016 0.016 100 V 0.414 0.214 0.053 0.033 0.016 0.016 300 V 0.413 0.213 0.053 0.033 0.016 0.016 10 mA 0.413 0.214 0.053 0.033 0.016 0.016 100 mA 0.393 0.213 0.053 0.033 0.016 0.016 1A 0.414 0.213 0.053 0.033 0.016 0.016 2A 0.413 0.213 0.053 0.033 0.016 0.016 100 Ω 0.414 0.
U2751A USB Modular Switch Matrix Features Introduction • 32 two-wire crosspoints in 4x8 configuration The Agilent U2751A USB modular switch matrix offers a high-quality, low-cost switching solution for automated testing. It has 32 two-wire cross points organized in a four rows by eight columns (4x8) configuration enabling connection with any combination of rows and columns, including multiple channels at the same time. It also features a relay cycle counter.
Agilent U2922A 32-Channel Terminal Block The U2922A terminal block is an optional accessory to be used with the U2751A. The U2922A, which weighs approximately 100 g with screw-type terminals, offers you a convenient and simple way of making connection to the switch matrix for prototyping applications or an actual system deployment. It allows the user to configure a wide variety of routing options and matrix topologies. Figure 1. U2922A with U2751A used as a standalone device Figure 2.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER CONSUMPTION • +12 VDC, 2 A maximum • Installation Category II Rear view OPERATING ENVIRONMENT • Operating temperature from 0 °C to +50 °C • Relative humidity at 20% to 85% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only 44.
Product specifications Model U2751A Without U2922A terminal block Channels/configuration With U2922A terminal block 4 × 8, 2-wire Switch type Armature latching Input characteristics (per channel) Max working voltage[1] • Standalone • Modular (Used with U2781A) 42 VDC/35 Vrms 180 VDC/180 Vrms Max transient voltage 300 Vrms Max current • Switch current • Carry current 2A 2A Power (W, VA)[2] 60 W, 62.
U2761A USB Modular Function/Arbitrary Waveform Generator Features Introduction • 20 MHz Sine and Square waveforms The Agilent U2761A is a 20 MHz USB modular function generator with arbitrary waveform and pulse generation capability. It can operate as a standalone or modular unit when used with the U2781A USB modular product chassis.
Product outlook and dimensions Front view Product characteristics and general specifications REMOTE INTERFACE • Hi-Speed USB 2.0* • USBTMC-USB488[1] POWER CONSUMPTION • +12 VDC, 2 A • Isolated ELV power source Rear view OPERATING ENVIRONMENT • Operating temperature from 0 °C to +50 °C • Operating humidity at 20% to 85% RH (non-condensing) • Altitude up to 2000 meters • Pollution Degree 2 • For indoor use only 41.00 mm Top view 117.
Product specifications and measurement characteristics Waveforms Standard Sine, Square, Ramp, Triangle, Pulse, DC Built-in arbitrary Exponential Rise, Exponential Fall, Negative Ramp Waveform characteristics Sine Frequency range Amplitude flatness[1] (relative to 1 kHz) Harmonic distortion[2] 1 μHz to 20 MHz (1 μHz resolution) < 100 kHz 0.2 dB 100 kHz to 1 MHz 0.35 dB 1 MHz to 20 MHz 0.
Waveform characteristics (continued) Arbitrary Frequency range 1 μHz to 200 kHz (1 μHz resolution) Waveform memory depth 64 kSa[1] Amplitude resolution 14 bits/sample (including sign) Sampling rate 50 MSa/s Minimum rise/fall time 36 ns (Typical) Linearity < 0.2% of peak output Settling Time < 250 ns to 0.
Trigger characteristics Trigger input Input Level TTL compatible Slope Rising and Falling, Selectable Pulse width > 100 ns Input impedance > 10 kΩ, DC coupled Latency < 500 ns Jitter (RMS) 6 ns (3.
Sweep Characteristics Waveforms Sine, Square, Ramp, Arbitrary Type Linear or Logarithmic Direction Up or Down Sweep time 1 ms to 500 s Trigger Single, External, or Internal 72
Ordering Information The table below list out the models and the respective optional accesories. For more information, please visit our web site or contact your local Agilent office. The complete list is available at www.agilent.com/find/contactus.
Part number Description U2701A USB modular oscilloscope (100 MHz)/U2702A USB modular oscilloscope (200 MHz) N2862A 10:1 passive probe 150 MHz 1.2 m (for U2701A) N2863A 10:1 passive probe 300 MHz 1.2 m (for U2702A) U2701A-200 10070C 1:1 passive probe 20 MHz 1.
www.agilent.com www.agilent.com/find/usbdaq www.agilent.com/find/usbmodular For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.axiestandard.